Experimental study on the lateral behavior of DSCT columns with corrugated inner tube

Taek Hee Han, Deokhee Won, Seungjun Kim, Young Jong Kang

Research output: Contribution to journalArticle

Abstract

A double-skinned composite tubular column with a corrugated internal tube (DSCT-CT) was suggested to reduce the thickness of the inner tube while maintaining the required buckling strength. The DSCT-CT was studied to evaluate its behavior under lateral loading, and its lateral behavior was compared with that of a DSCT column with a flat internal tube (DSCT-FT). Quasi-static tests were performed by applying cyclic lateral loadings to the two different DSCT columns. Their test results were compared to each other and to those of a solid RC column from other research. The test results showed that the DSCT-CT column had larger ductility than the DSCT-FT column, with an equivalent damping ratio. However, the DSCT-CT column showed a smaller bending moment resistance and energy-absorbing capacity than the DSCT-FT column. Overall, the test results showed that the performances of the DSCT columns were superior to that of the solid RC column in terms of strength, yield energy, ultimate energy, and energy-absorbing capacity. As a result of their superior moment capacities, the DSCT columns absorbed about 50 % more energy than the solid RC column. However, the DSCT columns showed lower energy ductility factors than the solid RC column because of their high yield energies.

Original languageEnglish
Pages (from-to)2855-2867
Number of pages13
JournalMaterials and Structures/Materiaux et Constructions
Volume48
Issue number9
DOIs
Publication statusPublished - 2014 Jul 23

Fingerprint

Ductility
Bending moments
Buckling
Yield stress
Damping
Composite materials

Keywords

  • Column
  • Composite
  • Concrete
  • Corrugate
  • Double skinned
  • DSCT

ASJC Scopus subject areas

  • Building and Construction
  • Civil and Structural Engineering
  • Mechanics of Materials
  • Materials Science(all)

Cite this

Experimental study on the lateral behavior of DSCT columns with corrugated inner tube. / Han, Taek Hee; Won, Deokhee; Kim, Seungjun; Kang, Young Jong.

In: Materials and Structures/Materiaux et Constructions, Vol. 48, No. 9, 23.07.2014, p. 2855-2867.

Research output: Contribution to journalArticle

@article{046550ac6f144486b38920d56ae58eab,
title = "Experimental study on the lateral behavior of DSCT columns with corrugated inner tube",
abstract = "A double-skinned composite tubular column with a corrugated internal tube (DSCT-CT) was suggested to reduce the thickness of the inner tube while maintaining the required buckling strength. The DSCT-CT was studied to evaluate its behavior under lateral loading, and its lateral behavior was compared with that of a DSCT column with a flat internal tube (DSCT-FT). Quasi-static tests were performed by applying cyclic lateral loadings to the two different DSCT columns. Their test results were compared to each other and to those of a solid RC column from other research. The test results showed that the DSCT-CT column had larger ductility than the DSCT-FT column, with an equivalent damping ratio. However, the DSCT-CT column showed a smaller bending moment resistance and energy-absorbing capacity than the DSCT-FT column. Overall, the test results showed that the performances of the DSCT columns were superior to that of the solid RC column in terms of strength, yield energy, ultimate energy, and energy-absorbing capacity. As a result of their superior moment capacities, the DSCT columns absorbed about 50 {\%} more energy than the solid RC column. However, the DSCT columns showed lower energy ductility factors than the solid RC column because of their high yield energies.",
keywords = "Column, Composite, Concrete, Corrugate, Double skinned, DSCT",
author = "Han, {Taek Hee} and Deokhee Won and Seungjun Kim and Kang, {Young Jong}",
year = "2014",
month = "7",
day = "23",
doi = "10.1617/s11527-014-0361-0",
language = "English",
volume = "48",
pages = "2855--2867",
journal = "Materials and Structures",
issn = "1359-5997",
publisher = "Springer Netherlands",
number = "9",

}

TY - JOUR

T1 - Experimental study on the lateral behavior of DSCT columns with corrugated inner tube

AU - Han, Taek Hee

AU - Won, Deokhee

AU - Kim, Seungjun

AU - Kang, Young Jong

PY - 2014/7/23

Y1 - 2014/7/23

N2 - A double-skinned composite tubular column with a corrugated internal tube (DSCT-CT) was suggested to reduce the thickness of the inner tube while maintaining the required buckling strength. The DSCT-CT was studied to evaluate its behavior under lateral loading, and its lateral behavior was compared with that of a DSCT column with a flat internal tube (DSCT-FT). Quasi-static tests were performed by applying cyclic lateral loadings to the two different DSCT columns. Their test results were compared to each other and to those of a solid RC column from other research. The test results showed that the DSCT-CT column had larger ductility than the DSCT-FT column, with an equivalent damping ratio. However, the DSCT-CT column showed a smaller bending moment resistance and energy-absorbing capacity than the DSCT-FT column. Overall, the test results showed that the performances of the DSCT columns were superior to that of the solid RC column in terms of strength, yield energy, ultimate energy, and energy-absorbing capacity. As a result of their superior moment capacities, the DSCT columns absorbed about 50 % more energy than the solid RC column. However, the DSCT columns showed lower energy ductility factors than the solid RC column because of their high yield energies.

AB - A double-skinned composite tubular column with a corrugated internal tube (DSCT-CT) was suggested to reduce the thickness of the inner tube while maintaining the required buckling strength. The DSCT-CT was studied to evaluate its behavior under lateral loading, and its lateral behavior was compared with that of a DSCT column with a flat internal tube (DSCT-FT). Quasi-static tests were performed by applying cyclic lateral loadings to the two different DSCT columns. Their test results were compared to each other and to those of a solid RC column from other research. The test results showed that the DSCT-CT column had larger ductility than the DSCT-FT column, with an equivalent damping ratio. However, the DSCT-CT column showed a smaller bending moment resistance and energy-absorbing capacity than the DSCT-FT column. Overall, the test results showed that the performances of the DSCT columns were superior to that of the solid RC column in terms of strength, yield energy, ultimate energy, and energy-absorbing capacity. As a result of their superior moment capacities, the DSCT columns absorbed about 50 % more energy than the solid RC column. However, the DSCT columns showed lower energy ductility factors than the solid RC column because of their high yield energies.

KW - Column

KW - Composite

KW - Concrete

KW - Corrugate

KW - Double skinned

KW - DSCT

UR - http://www.scopus.com/inward/record.url?scp=84938294263&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84938294263&partnerID=8YFLogxK

U2 - 10.1617/s11527-014-0361-0

DO - 10.1617/s11527-014-0361-0

M3 - Article

AN - SCOPUS:84938294263

VL - 48

SP - 2855

EP - 2867

JO - Materials and Structures

JF - Materials and Structures

SN - 1359-5997

IS - 9

ER -