TY - JOUR
T1 - Factors for good near and distance visual outcomes of multifocal intraocular lens with inferior segmental near add
AU - Kim, Jung Wan
AU - Eom, Youngsub
AU - Chung, Hyun Woo
AU - Song, Jong Suk
AU - Jeong, Ji Won
AU - Park, Seh Kwang
AU - Kim, Hyo Myung
N1 - Funding Information:
This study was supported by Korea University grants (K1625491, K1722121, K1811051, K1913161, and K2010921) and by the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science and ICT (2018R1C1B6002794). The funding source had no role in the design or conduct of this research.
Publisher Copyright:
© 2020, Springer-Verlag GmbH Germany, part of Springer Nature.
PY - 2020/8/1
Y1 - 2020/8/1
N2 - Purpose: This study was conducted to investigate factors related to postoperative good near and distance visual outcomes in the Lentis Mplus LS-313 MF20 (Oculentis Gmbh, Berlin, Germany) intraocular lens (IOL)-implanted eye. Methods: A retrospective cross-sectional study analyzed a total of 198 eyes of 198 patients. Patients with 20/20-or-more uncorrected distance visual acuity (UDVA, 5 m) and J2-or-more uncorrected near visual acuity (UNVA, 40 cm) were distributed into the good visual outcome (GVO) group (n = 96), and the remaining patients were distributed into the moderate visual outcome (MVO) group (n = 102). Differences between the two groups were compared for patient age, preoperative measurements (kappa distance, kappa angle, and pupil size), and postoperative measurements (residual sphere, cylinder, and spherical equivalent) to explore factors related to good visual outcomes after IOL implantation. Results: The average age of the GVO group (56.2 years) was significantly lower than that of the MVO group (58.6 years), and the average kappa distance of the former was significantly smaller than that of the latter. However, there were no significant differences between the two groups in kappa angle and pupil size. Notably, multivariate binary regression analysis revealed that multiple factors including age, residual cylinder, and spherical equivalent were associated with good visual outcomes. Based on the receiver operating characteristic curve, cutoff values regarded as good visual outcome following cataract surgery were calculated to be − 0.38 CD in residual cylinder and − 0.32 D in residual spherical equivalent. Conclusions: Patients with implanted Lentis Mplus LS-313 MF20 IOL who are young, had small kappa distance, and had low levels of postoperative residual cylinder and spherical equivalent tended to exhibit good vision at both near and distance. These results imply that surgeons should minimize postoperative residual cylinder and spherical equivalent to provide good visual outcomes to patients with implanted Lentis Mplus LS-313 MF20 IOL.
AB - Purpose: This study was conducted to investigate factors related to postoperative good near and distance visual outcomes in the Lentis Mplus LS-313 MF20 (Oculentis Gmbh, Berlin, Germany) intraocular lens (IOL)-implanted eye. Methods: A retrospective cross-sectional study analyzed a total of 198 eyes of 198 patients. Patients with 20/20-or-more uncorrected distance visual acuity (UDVA, 5 m) and J2-or-more uncorrected near visual acuity (UNVA, 40 cm) were distributed into the good visual outcome (GVO) group (n = 96), and the remaining patients were distributed into the moderate visual outcome (MVO) group (n = 102). Differences between the two groups were compared for patient age, preoperative measurements (kappa distance, kappa angle, and pupil size), and postoperative measurements (residual sphere, cylinder, and spherical equivalent) to explore factors related to good visual outcomes after IOL implantation. Results: The average age of the GVO group (56.2 years) was significantly lower than that of the MVO group (58.6 years), and the average kappa distance of the former was significantly smaller than that of the latter. However, there were no significant differences between the two groups in kappa angle and pupil size. Notably, multivariate binary regression analysis revealed that multiple factors including age, residual cylinder, and spherical equivalent were associated with good visual outcomes. Based on the receiver operating characteristic curve, cutoff values regarded as good visual outcome following cataract surgery were calculated to be − 0.38 CD in residual cylinder and − 0.32 D in residual spherical equivalent. Conclusions: Patients with implanted Lentis Mplus LS-313 MF20 IOL who are young, had small kappa distance, and had low levels of postoperative residual cylinder and spherical equivalent tended to exhibit good vision at both near and distance. These results imply that surgeons should minimize postoperative residual cylinder and spherical equivalent to provide good visual outcomes to patients with implanted Lentis Mplus LS-313 MF20 IOL.
KW - Intraocular lens
KW - Kappa distance
KW - Multifocal
KW - Refractive
KW - Residual refractive error
KW - Visual outcomes
UR - http://www.scopus.com/inward/record.url?scp=85085752633&partnerID=8YFLogxK
U2 - 10.1007/s00417-020-04761-1
DO - 10.1007/s00417-020-04761-1
M3 - Article
C2 - 32472200
AN - SCOPUS:85085752633
VL - 258
SP - 1735
EP - 1743
JO - Albrecht von Graefes Archiv für Klinische und Experimentelle Ophthalmologie
JF - Albrecht von Graefes Archiv für Klinische und Experimentelle Ophthalmologie
SN - 0065-6100
IS - 8
ER -