Fast timing measurement for CMS RPC Phase-II upgrade

A. Fagot, M. Gul, C. Roskas, M. Tytgat, N. Zaganidis, S. Fonseca De Souza, A. Santoro, F. Torres Da Silva De Araujo, A. Aleksandrov, R. Hadjiiska, P. Iaydjiev, M. Rodozov, M. Shopova, G. Sultanov, A. Dimitrov, L. Litov, B. Pavlov, P. Petkov, A. Petrov, S. J. QianD. Han, W. Yi, C. Avila, A. Cabrera, C. Carrillo, M. Segura, S. Aly, Y. Assran, A. Mahrous, A. Mohamed, C. Combaret, M. Gouzevitch, G. Grenier, F. Lagarde, I. B. Laktineh, H. Mathez, L. Mirabito, K. Shchablo, I. Bagaturia, D. Lomidze, I. Lomidze, L. M. Pant, V. Bhatnagar, R. Gupta, R. Kumari, M. Lohan, J. B. Singh, V. Amoozegar, B. Boghrati, H. Ghasemy, S. Malmir, M. Mohammadi Najafabadi, M. Abbrescia, A. Gelmi, G. Iaselli, S. Lezki, G. Pugliese, L. Benussi, S. Bianco, D. Piccolo, F. Primavera, S. Buontempo, A. Crescenzo, G. Galati, F. Fienga, I. Orso, L. Lista, S. Meola, P. Paolucci, E. Voevodina, A. Braghieri, P. Montagna, M. Ressegotti, C. Riccardi, P. Salvini, P. Vitulo, S. W. Cho, Suyong Choi, Byungsik Hong, K. S. Lee, J. H. Lim, Sung Keun Park, J. Goh, T. J. Kim, S. Carrillo Moreno, O. Miguel Colin, F. Vazquez Valencia, S. Carpinteyro Bernardino, J. Eysermans, I. Pedraza, C. Uribe Estrada, R. Reyes-Almanza, M. C. Duran-Osuna, M. Ramirez-Garcia, G. Ramirez-Sanchez, A. Sanchez-Hernandez, R. I. Rabadan-Trejo, H. Castilla-Valdez, A. Radi, H. Hoorani, S. Muhammad, M. A. Shah, I. Crotty

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

With the increase of the LHC luminosity foreseen in the coming years, many detectors currently used in the different LHC experiments will be dramatically impacted and some need to be replaced or upgraded. The new ones should be capable to provide time information to reduce the data ambiguity due to the expected high pileup. We propose to equip CMS high |η| muon chambers with pairs of single gap RPC detectors read out by long pickup strips PCB. The precise time measurement (0<15 ps) of the signal induced by particles crossing the detector on both ends of each strip will give an accurate measurement of the position of the incoming particle along the strip. The absolute time measurement, determined by RPC signal (around 1.5 ns) will also reduce the data ambiguity due to the highly expected pileup and help to identify Heavy Stable Charged Particles (HSCP). The development of a specific electronic chain (analog front-end ASIC, time-to-digital converter stage and printed circuit board design) and the corresponding first results on prototype chambers are presented.

Original languageEnglish
Article numberC09001
JournalJournal of Instrumentation
Volume13
Issue number9
DOIs
Publication statusPublished - 2018 Sep 27

Keywords

  • Data acquisition circuits
  • Front-end electronics for detector readout
  • Resistive-plate chambers

ASJC Scopus subject areas

  • Instrumentation
  • Mathematical Physics

Fingerprint Dive into the research topics of 'Fast timing measurement for CMS RPC Phase-II upgrade'. Together they form a unique fingerprint.

Cite this