Feasibility of phase contrast radiography in cat normal spinal cord

Joon Shik Yoon, G. S. Kim, S. J. Kim, Jung Min Kim, Seong Beom Koh, Sang-Il Suh, J. H. Je, S. K. Seol, C. H.oh

Research output: Contribution to journalArticle

Abstract

Phase contrast radiography (PCR) techniques are becoming important analytical tools for imaging biological samples. The authors aimed to evaluate a possible use of PCR in examining radiological microscopic findings of cat normal spinal cord without any staining procedure in paraffin blocked specimens. The PCR experiments were implemented at the International Consortium of Phase Contrast Imaging and Radiology (ICPCIR) (7B2) beamline at the Pohang Light Source in Korea. In the phase contrast radiography, the grey and white matters of the spinal cord were demarcated with the grey matter in an 'H' shape, similar to the histological structure by light microscopy. The dorsal, intermediate and ventral grey matters were clearly visible as well as other columns and funiculi. The authors suggest that PCR could be a useful tool for microscopic morphological investigation of spinal cord without any staining procedure.

Original languageEnglish
Pages (from-to)314-318
Number of pages5
JournalImaging Science Journal
Volume56
Issue number6
DOIs
Publication statusPublished - 2008 Dec 1

Fingerprint

Radiography
Imaging techniques
Radiology
Paraffins
Optical microscopy
Light sources
Experiments

Keywords

  • Phase contrast microscopies
  • Spinal cord
  • Without staining procedure

ASJC Scopus subject areas

  • Media Technology
  • Computer Vision and Pattern Recognition

Cite this

Feasibility of phase contrast radiography in cat normal spinal cord. / Yoon, Joon Shik; Kim, G. S.; Kim, S. J.; Kim, Jung Min; Koh, Seong Beom; Suh, Sang-Il; Je, J. H.; Seol, S. K.; H.oh, C.

In: Imaging Science Journal, Vol. 56, No. 6, 01.12.2008, p. 314-318.

Research output: Contribution to journalArticle

Yoon, Joon Shik ; Kim, G. S. ; Kim, S. J. ; Kim, Jung Min ; Koh, Seong Beom ; Suh, Sang-Il ; Je, J. H. ; Seol, S. K. ; H.oh, C. / Feasibility of phase contrast radiography in cat normal spinal cord. In: Imaging Science Journal. 2008 ; Vol. 56, No. 6. pp. 314-318.
@article{9e683770cc0d41ca8e7ef424f393dd73,
title = "Feasibility of phase contrast radiography in cat normal spinal cord",
abstract = "Phase contrast radiography (PCR) techniques are becoming important analytical tools for imaging biological samples. The authors aimed to evaluate a possible use of PCR in examining radiological microscopic findings of cat normal spinal cord without any staining procedure in paraffin blocked specimens. The PCR experiments were implemented at the International Consortium of Phase Contrast Imaging and Radiology (ICPCIR) (7B2) beamline at the Pohang Light Source in Korea. In the phase contrast radiography, the grey and white matters of the spinal cord were demarcated with the grey matter in an 'H' shape, similar to the histological structure by light microscopy. The dorsal, intermediate and ventral grey matters were clearly visible as well as other columns and funiculi. The authors suggest that PCR could be a useful tool for microscopic morphological investigation of spinal cord without any staining procedure.",
keywords = "Phase contrast microscopies, Spinal cord, Without staining procedure",
author = "Yoon, {Joon Shik} and Kim, {G. S.} and Kim, {S. J.} and Kim, {Jung Min} and Koh, {Seong Beom} and Sang-Il Suh and Je, {J. H.} and Seol, {S. K.} and C. H.oh",
year = "2008",
month = "12",
day = "1",
doi = "10.1179/174313108X319405",
language = "English",
volume = "56",
pages = "314--318",
journal = "Imaging Science Journal",
issn = "1368-2199",
publisher = "Maney Publishing",
number = "6",

}

TY - JOUR

T1 - Feasibility of phase contrast radiography in cat normal spinal cord

AU - Yoon, Joon Shik

AU - Kim, G. S.

AU - Kim, S. J.

AU - Kim, Jung Min

AU - Koh, Seong Beom

AU - Suh, Sang-Il

AU - Je, J. H.

AU - Seol, S. K.

AU - H.oh, C.

PY - 2008/12/1

Y1 - 2008/12/1

N2 - Phase contrast radiography (PCR) techniques are becoming important analytical tools for imaging biological samples. The authors aimed to evaluate a possible use of PCR in examining radiological microscopic findings of cat normal spinal cord without any staining procedure in paraffin blocked specimens. The PCR experiments were implemented at the International Consortium of Phase Contrast Imaging and Radiology (ICPCIR) (7B2) beamline at the Pohang Light Source in Korea. In the phase contrast radiography, the grey and white matters of the spinal cord were demarcated with the grey matter in an 'H' shape, similar to the histological structure by light microscopy. The dorsal, intermediate and ventral grey matters were clearly visible as well as other columns and funiculi. The authors suggest that PCR could be a useful tool for microscopic morphological investigation of spinal cord without any staining procedure.

AB - Phase contrast radiography (PCR) techniques are becoming important analytical tools for imaging biological samples. The authors aimed to evaluate a possible use of PCR in examining radiological microscopic findings of cat normal spinal cord without any staining procedure in paraffin blocked specimens. The PCR experiments were implemented at the International Consortium of Phase Contrast Imaging and Radiology (ICPCIR) (7B2) beamline at the Pohang Light Source in Korea. In the phase contrast radiography, the grey and white matters of the spinal cord were demarcated with the grey matter in an 'H' shape, similar to the histological structure by light microscopy. The dorsal, intermediate and ventral grey matters were clearly visible as well as other columns and funiculi. The authors suggest that PCR could be a useful tool for microscopic morphological investigation of spinal cord without any staining procedure.

KW - Phase contrast microscopies

KW - Spinal cord

KW - Without staining procedure

UR - http://www.scopus.com/inward/record.url?scp=56749105610&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=56749105610&partnerID=8YFLogxK

U2 - 10.1179/174313108X319405

DO - 10.1179/174313108X319405

M3 - Article

VL - 56

SP - 314

EP - 318

JO - Imaging Science Journal

JF - Imaging Science Journal

SN - 1368-2199

IS - 6

ER -