Punctal plugs are an effective treatment option for patients with aqueous-deficient dry eye refractory to topical medications. However, punctal plugs are not commonly used in clinical practice mainly because of various misconceptions, rather than clinical complications. We analyzed previous studies and present 5 misconceptions related to punctal plugs. The first and most important misconception is that ocular surface inflammation should be sufficiently controlled before punctal plug insertion. However, it is unclear how ocular surface inflammation can be sufficiently controlled in patients refractory to conventional topical medications. The second misconception is that silicone punctal plugs are made of nonabsorbable materials and, therefore, permanent. In fact, silicone plugs are reversible and can be easily removed if necessary. Therefore, depending on the specific type, nonabsorbable plugs may be classified as reversible or permanent. The third misconception is that punctal plugs disrupt normal tear drainage. However, punctal plugs maintain natural tears on the ocular surface for extended periods and reduce the frequency of artificial tear use. The fourth is that all punctal and canalicular plugs have similar effects. The efficacy and complication rates differ depending on plug types. The fifth misconception about punctal plugs is that they are effective only in aqueous-deficient dry eye disease. Many studies have reported that plugs are effective in a variety of ocular diseases and conditions. Understanding these 5 misconceptions may provide an opportunity to rethink the use of silicone punctal plugs in clinical practice.

Original languageEnglish
Pages (from-to)S58-S61
JournalCornea
Volume37
DOIs
Publication statusPublished - 2018 Nov 1

Fingerprint

Eye Diseases
Tears
Punctal Plugs
Inflammation
Silicones
Drainage
Therapeutics
Lubricant Eye Drops

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Five Misconceptions Related to Punctal Plugs in Dry Eye Management. / Song, Jong-Suk; Woo, In Ho; Eom, Youngsub; Kim, Hyo Myung.

In: Cornea, Vol. 37, 01.11.2018, p. S58-S61.

Research output: Contribution to journalArticle

@article{358d95bbdc804240a9b04020280430ee,
title = "Five Misconceptions Related to Punctal Plugs in Dry Eye Management",
abstract = "Punctal plugs are an effective treatment option for patients with aqueous-deficient dry eye refractory to topical medications. However, punctal plugs are not commonly used in clinical practice mainly because of various misconceptions, rather than clinical complications. We analyzed previous studies and present 5 misconceptions related to punctal plugs. The first and most important misconception is that ocular surface inflammation should be sufficiently controlled before punctal plug insertion. However, it is unclear how ocular surface inflammation can be sufficiently controlled in patients refractory to conventional topical medications. The second misconception is that silicone punctal plugs are made of nonabsorbable materials and, therefore, permanent. In fact, silicone plugs are reversible and can be easily removed if necessary. Therefore, depending on the specific type, nonabsorbable plugs may be classified as reversible or permanent. The third misconception is that punctal plugs disrupt normal tear drainage. However, punctal plugs maintain natural tears on the ocular surface for extended periods and reduce the frequency of artificial tear use. The fourth is that all punctal and canalicular plugs have similar effects. The efficacy and complication rates differ depending on plug types. The fifth misconception about punctal plugs is that they are effective only in aqueous-deficient dry eye disease. Many studies have reported that plugs are effective in a variety of ocular diseases and conditions. Understanding these 5 misconceptions may provide an opportunity to rethink the use of silicone punctal plugs in clinical practice.",
author = "Jong-Suk Song and Woo, {In Ho} and Youngsub Eom and Kim, {Hyo Myung}",
year = "2018",
month = "11",
day = "1",
doi = "10.1097/ICO.0000000000001734",
language = "English",
volume = "37",
pages = "S58--S61",
journal = "Cornea",
issn = "0277-3740",
publisher = "Lippincott Williams and Wilkins",

}

TY - JOUR

T1 - Five Misconceptions Related to Punctal Plugs in Dry Eye Management

AU - Song, Jong-Suk

AU - Woo, In Ho

AU - Eom, Youngsub

AU - Kim, Hyo Myung

PY - 2018/11/1

Y1 - 2018/11/1

N2 - Punctal plugs are an effective treatment option for patients with aqueous-deficient dry eye refractory to topical medications. However, punctal plugs are not commonly used in clinical practice mainly because of various misconceptions, rather than clinical complications. We analyzed previous studies and present 5 misconceptions related to punctal plugs. The first and most important misconception is that ocular surface inflammation should be sufficiently controlled before punctal plug insertion. However, it is unclear how ocular surface inflammation can be sufficiently controlled in patients refractory to conventional topical medications. The second misconception is that silicone punctal plugs are made of nonabsorbable materials and, therefore, permanent. In fact, silicone plugs are reversible and can be easily removed if necessary. Therefore, depending on the specific type, nonabsorbable plugs may be classified as reversible or permanent. The third misconception is that punctal plugs disrupt normal tear drainage. However, punctal plugs maintain natural tears on the ocular surface for extended periods and reduce the frequency of artificial tear use. The fourth is that all punctal and canalicular plugs have similar effects. The efficacy and complication rates differ depending on plug types. The fifth misconception about punctal plugs is that they are effective only in aqueous-deficient dry eye disease. Many studies have reported that plugs are effective in a variety of ocular diseases and conditions. Understanding these 5 misconceptions may provide an opportunity to rethink the use of silicone punctal plugs in clinical practice.

AB - Punctal plugs are an effective treatment option for patients with aqueous-deficient dry eye refractory to topical medications. However, punctal plugs are not commonly used in clinical practice mainly because of various misconceptions, rather than clinical complications. We analyzed previous studies and present 5 misconceptions related to punctal plugs. The first and most important misconception is that ocular surface inflammation should be sufficiently controlled before punctal plug insertion. However, it is unclear how ocular surface inflammation can be sufficiently controlled in patients refractory to conventional topical medications. The second misconception is that silicone punctal plugs are made of nonabsorbable materials and, therefore, permanent. In fact, silicone plugs are reversible and can be easily removed if necessary. Therefore, depending on the specific type, nonabsorbable plugs may be classified as reversible or permanent. The third misconception is that punctal plugs disrupt normal tear drainage. However, punctal plugs maintain natural tears on the ocular surface for extended periods and reduce the frequency of artificial tear use. The fourth is that all punctal and canalicular plugs have similar effects. The efficacy and complication rates differ depending on plug types. The fifth misconception about punctal plugs is that they are effective only in aqueous-deficient dry eye disease. Many studies have reported that plugs are effective in a variety of ocular diseases and conditions. Understanding these 5 misconceptions may provide an opportunity to rethink the use of silicone punctal plugs in clinical practice.

UR - http://www.scopus.com/inward/record.url?scp=85054774320&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85054774320&partnerID=8YFLogxK

U2 - 10.1097/ICO.0000000000001734

DO - 10.1097/ICO.0000000000001734

M3 - Article

C2 - 30211751

AN - SCOPUS:85054774320

VL - 37

SP - S58-S61

JO - Cornea

JF - Cornea

SN - 0277-3740

ER -