Abstract

In this paper, we present the design, fabrication, and performance evaluation of a polyimide-based flexible neural probe for the precise site stimulation and recording in the deep brain. The probe consists of five electrodes: one for stimulation, another for ground and the other three for recording electrodes. This probe is designed to be foldable, enabling easy insertion into the deep brain via temporary tungsten guide sticks. Because of its small cross-sectional area and the flexibility of the polyimide, the probe causes minimum damage to the neural tissue and does not show any evidence of serious immune reactions such as high density of macrophage or microglia. Around the simulation electrodes, an additional ground electrode prevents the stimulation of the undesired sites in the brain. To ensure we stimulate the target point specifically, for instance STh in this study, we confirm through both finite element analyses and in vitro tests. With the additional ground electrodes, we observe the leakage power decreased by about 80%. To check the performance of the probe, we demonstrate animal experiments using rats, and neural spike signals from STh in the 7-mm deep brain are successfully recorded after implantation.

Original languageEnglish
Pages (from-to)436-443
Number of pages8
JournalBiosensors and Bioelectronics
Volume117
DOIs
Publication statusPublished - 2018 Oct 15

Fingerprint

Brain
Electrodes
Metals
Grounding electrodes
Polyimides
Antigen-antibody reactions
Finite Element Analysis
Tungsten
Macrophages
Microglia
Rats
Animals
Tissue
Fabrication
Experiments

Keywords

  • Deep brain stimulation
  • Flexible neural probe
  • Implantable device
  • Localized stimulation

ASJC Scopus subject areas

  • Biotechnology
  • Biophysics
  • Biomedical Engineering
  • Electrochemistry

Cite this

Flexible deep brain neural probe for localized stimulation and detection with metal guide. / Kim, Jeong Hun; Lee, Geon Hui; Kim, Seohyeon; Chung, Hyo Won; Lee, Joong Hoon; Lee, Seung Min; Kang, Chong-Yun; Lee, Sang Hoon.

In: Biosensors and Bioelectronics, Vol. 117, 15.10.2018, p. 436-443.

Research output: Contribution to journalArticle

Kim, Jeong Hun ; Lee, Geon Hui ; Kim, Seohyeon ; Chung, Hyo Won ; Lee, Joong Hoon ; Lee, Seung Min ; Kang, Chong-Yun ; Lee, Sang Hoon. / Flexible deep brain neural probe for localized stimulation and detection with metal guide. In: Biosensors and Bioelectronics. 2018 ; Vol. 117. pp. 436-443.
@article{aedcd112ddad402199067e07b5404ece,
title = "Flexible deep brain neural probe for localized stimulation and detection with metal guide",
abstract = "In this paper, we present the design, fabrication, and performance evaluation of a polyimide-based flexible neural probe for the precise site stimulation and recording in the deep brain. The probe consists of five electrodes: one for stimulation, another for ground and the other three for recording electrodes. This probe is designed to be foldable, enabling easy insertion into the deep brain via temporary tungsten guide sticks. Because of its small cross-sectional area and the flexibility of the polyimide, the probe causes minimum damage to the neural tissue and does not show any evidence of serious immune reactions such as high density of macrophage or microglia. Around the simulation electrodes, an additional ground electrode prevents the stimulation of the undesired sites in the brain. To ensure we stimulate the target point specifically, for instance STh in this study, we confirm through both finite element analyses and in vitro tests. With the additional ground electrodes, we observe the leakage power decreased by about 80{\%}. To check the performance of the probe, we demonstrate animal experiments using rats, and neural spike signals from STh in the 7-mm deep brain are successfully recorded after implantation.",
keywords = "Deep brain stimulation, Flexible neural probe, Implantable device, Localized stimulation",
author = "Kim, {Jeong Hun} and Lee, {Geon Hui} and Seohyeon Kim and Chung, {Hyo Won} and Lee, {Joong Hoon} and Lee, {Seung Min} and Chong-Yun Kang and Lee, {Sang Hoon}",
year = "2018",
month = "10",
day = "15",
doi = "10.1016/j.bios.2018.06.035",
language = "English",
volume = "117",
pages = "436--443",
journal = "Biosensors and Bioelectronics",
issn = "0956-5663",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - Flexible deep brain neural probe for localized stimulation and detection with metal guide

AU - Kim, Jeong Hun

AU - Lee, Geon Hui

AU - Kim, Seohyeon

AU - Chung, Hyo Won

AU - Lee, Joong Hoon

AU - Lee, Seung Min

AU - Kang, Chong-Yun

AU - Lee, Sang Hoon

PY - 2018/10/15

Y1 - 2018/10/15

N2 - In this paper, we present the design, fabrication, and performance evaluation of a polyimide-based flexible neural probe for the precise site stimulation and recording in the deep brain. The probe consists of five electrodes: one for stimulation, another for ground and the other three for recording electrodes. This probe is designed to be foldable, enabling easy insertion into the deep brain via temporary tungsten guide sticks. Because of its small cross-sectional area and the flexibility of the polyimide, the probe causes minimum damage to the neural tissue and does not show any evidence of serious immune reactions such as high density of macrophage or microglia. Around the simulation electrodes, an additional ground electrode prevents the stimulation of the undesired sites in the brain. To ensure we stimulate the target point specifically, for instance STh in this study, we confirm through both finite element analyses and in vitro tests. With the additional ground electrodes, we observe the leakage power decreased by about 80%. To check the performance of the probe, we demonstrate animal experiments using rats, and neural spike signals from STh in the 7-mm deep brain are successfully recorded after implantation.

AB - In this paper, we present the design, fabrication, and performance evaluation of a polyimide-based flexible neural probe for the precise site stimulation and recording in the deep brain. The probe consists of five electrodes: one for stimulation, another for ground and the other three for recording electrodes. This probe is designed to be foldable, enabling easy insertion into the deep brain via temporary tungsten guide sticks. Because of its small cross-sectional area and the flexibility of the polyimide, the probe causes minimum damage to the neural tissue and does not show any evidence of serious immune reactions such as high density of macrophage or microglia. Around the simulation electrodes, an additional ground electrode prevents the stimulation of the undesired sites in the brain. To ensure we stimulate the target point specifically, for instance STh in this study, we confirm through both finite element analyses and in vitro tests. With the additional ground electrodes, we observe the leakage power decreased by about 80%. To check the performance of the probe, we demonstrate animal experiments using rats, and neural spike signals from STh in the 7-mm deep brain are successfully recorded after implantation.

KW - Deep brain stimulation

KW - Flexible neural probe

KW - Implantable device

KW - Localized stimulation

UR - http://www.scopus.com/inward/record.url?scp=85049357803&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85049357803&partnerID=8YFLogxK

U2 - 10.1016/j.bios.2018.06.035

DO - 10.1016/j.bios.2018.06.035

M3 - Article

VL - 117

SP - 436

EP - 443

JO - Biosensors and Bioelectronics

JF - Biosensors and Bioelectronics

SN - 0956-5663

ER -