Fluorescence X-ray computed tomography (FXCT) using a position-sensitive CdTe detector

Changyeon Yoon, Won Ho Lee

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

This research involved a 3D simulation of a non-destructive test to detect fluorescence X-rays with a position-sensitive CdTe detector. Simulations were performed under various conditions and on different types of phantoms. All simulations were based on fluorescence X-ray computed tomography (FXCT) using a Monte Carlo method. In general, conventional computed tomography (CT) analyzes materials based on their attenuation coefficients, and is highly dependent on the densities of the materials; hence, discriminating between materials of similar density can be difficult, even if their atomic numbers differ. In this research, the material was exposed to an X-ray source, and the characteristic X-ray was measured by using a 2-dimensional (2D) CdTe planar detector array and was then used to reconstruct a 3-dimensional (3D) image. A 2D CdTe pixelated array has a large detection area and operates with a compact cooling device. Because atoms have their own characteristic X-ray energy spectra, our system was even able to discriminate between materials with similar densities, provided the materials were composed of elements with different atomic numbers. In this research, FXCT was applied to distinguish between various materials, and real-world simulations were performed to verify the feasibility of our system for non-destructive inspection applications.

Original languageEnglish
Pages (from-to)122-128
Number of pages7
JournalJournal of the Korean Physical Society
Volume64
Issue number1
DOIs
Publication statusPublished - 2014 Jan 1

Fingerprint

tomography
fluorescence
detectors
x rays
simulation
nondestructive tests
attenuation coefficients
Monte Carlo method
inspection
energy spectra
cooling
atoms

Keywords

  • 2D CdTe detector
  • Characteristic X-ray
  • FXCT

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

Fluorescence X-ray computed tomography (FXCT) using a position-sensitive CdTe detector. / Yoon, Changyeon; Lee, Won Ho.

In: Journal of the Korean Physical Society, Vol. 64, No. 1, 01.01.2014, p. 122-128.

Research output: Contribution to journalArticle

@article{a3b3cacf67eb46a9a57e9dda38aea3e7,
title = "Fluorescence X-ray computed tomography (FXCT) using a position-sensitive CdTe detector",
abstract = "This research involved a 3D simulation of a non-destructive test to detect fluorescence X-rays with a position-sensitive CdTe detector. Simulations were performed under various conditions and on different types of phantoms. All simulations were based on fluorescence X-ray computed tomography (FXCT) using a Monte Carlo method. In general, conventional computed tomography (CT) analyzes materials based on their attenuation coefficients, and is highly dependent on the densities of the materials; hence, discriminating between materials of similar density can be difficult, even if their atomic numbers differ. In this research, the material was exposed to an X-ray source, and the characteristic X-ray was measured by using a 2-dimensional (2D) CdTe planar detector array and was then used to reconstruct a 3-dimensional (3D) image. A 2D CdTe pixelated array has a large detection area and operates with a compact cooling device. Because atoms have their own characteristic X-ray energy spectra, our system was even able to discriminate between materials with similar densities, provided the materials were composed of elements with different atomic numbers. In this research, FXCT was applied to distinguish between various materials, and real-world simulations were performed to verify the feasibility of our system for non-destructive inspection applications.",
keywords = "2D CdTe detector, Characteristic X-ray, FXCT",
author = "Changyeon Yoon and Lee, {Won Ho}",
year = "2014",
month = "1",
day = "1",
doi = "10.3938/jkps.64.122",
language = "English",
volume = "64",
pages = "122--128",
journal = "Journal of the Korean Physical Society",
issn = "0374-4884",
publisher = "Korean Physical Society",
number = "1",

}

TY - JOUR

T1 - Fluorescence X-ray computed tomography (FXCT) using a position-sensitive CdTe detector

AU - Yoon, Changyeon

AU - Lee, Won Ho

PY - 2014/1/1

Y1 - 2014/1/1

N2 - This research involved a 3D simulation of a non-destructive test to detect fluorescence X-rays with a position-sensitive CdTe detector. Simulations were performed under various conditions and on different types of phantoms. All simulations were based on fluorescence X-ray computed tomography (FXCT) using a Monte Carlo method. In general, conventional computed tomography (CT) analyzes materials based on their attenuation coefficients, and is highly dependent on the densities of the materials; hence, discriminating between materials of similar density can be difficult, even if their atomic numbers differ. In this research, the material was exposed to an X-ray source, and the characteristic X-ray was measured by using a 2-dimensional (2D) CdTe planar detector array and was then used to reconstruct a 3-dimensional (3D) image. A 2D CdTe pixelated array has a large detection area and operates with a compact cooling device. Because atoms have their own characteristic X-ray energy spectra, our system was even able to discriminate between materials with similar densities, provided the materials were composed of elements with different atomic numbers. In this research, FXCT was applied to distinguish between various materials, and real-world simulations were performed to verify the feasibility of our system for non-destructive inspection applications.

AB - This research involved a 3D simulation of a non-destructive test to detect fluorescence X-rays with a position-sensitive CdTe detector. Simulations were performed under various conditions and on different types of phantoms. All simulations were based on fluorescence X-ray computed tomography (FXCT) using a Monte Carlo method. In general, conventional computed tomography (CT) analyzes materials based on their attenuation coefficients, and is highly dependent on the densities of the materials; hence, discriminating between materials of similar density can be difficult, even if their atomic numbers differ. In this research, the material was exposed to an X-ray source, and the characteristic X-ray was measured by using a 2-dimensional (2D) CdTe planar detector array and was then used to reconstruct a 3-dimensional (3D) image. A 2D CdTe pixelated array has a large detection area and operates with a compact cooling device. Because atoms have their own characteristic X-ray energy spectra, our system was even able to discriminate between materials with similar densities, provided the materials were composed of elements with different atomic numbers. In this research, FXCT was applied to distinguish between various materials, and real-world simulations were performed to verify the feasibility of our system for non-destructive inspection applications.

KW - 2D CdTe detector

KW - Characteristic X-ray

KW - FXCT

UR - http://www.scopus.com/inward/record.url?scp=84892544568&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84892544568&partnerID=8YFLogxK

U2 - 10.3938/jkps.64.122

DO - 10.3938/jkps.64.122

M3 - Article

AN - SCOPUS:84892544568

VL - 64

SP - 122

EP - 128

JO - Journal of the Korean Physical Society

JF - Journal of the Korean Physical Society

SN - 0374-4884

IS - 1