Abstract

Current fouling indices typically employed in RO practices, such as silt density index (SDI) and modified fouling index (MFI), have suffered greatly from their inability to predict actual fouling potential primarily due to the erroneous interpretation of fouling mechanisms. Our findings clearly demonstrated that the effect of pore blocking should be excluded during fouling index measurements to simulate real RO applications. Thus, new concept of cake fouling index (CFI) was developed in order to accurately evaluate true fouling cake layer resistance. Specifically, the CFI was determined through consecutive filtration tests by subtracting the flux decline of the secondary filtration from that of the first one to eliminate the effect of pore blocking. The results proved that CFI better predicts the degree of fouling rate in RO experiments than MFI. It was also revealed that it could be utilized as a useful tool for identifying and evaluating the fouling mechanisms. Through a comparison of MFI and CFI, it was shown that pore blocking was enhanced as much as cake formation when pH decreased, while divalent cations (Ca<sup>2+</sup>) increased only cake formation on the membrane surface. This newly developed index refining existing MFI method is expected to provide more precise information about RO membrane fouling, especially for the design of effective pretreatment processes.

Original languageEnglish
Pages (from-to)57-64
Number of pages8
JournalJournal of Membrane Science
Volume490
DOIs
Publication statusPublished - 2015 Sep 5

Fingerprint

fouling
Fouling
Membranes
evaluation
Divalent Cations
porosity
membranes
Membrane fouling
Silt
refining
Refining
pretreatment

Keywords

  • Cake fouling index (CFI)
  • Fouling mechanism
  • Modified fouling index (MFI)
  • RO membrane fouling
  • Silt density index (SDI)

ASJC Scopus subject areas

  • Physical and Theoretical Chemistry
  • Materials Science(all)
  • Biochemistry
  • Filtration and Separation

Cite this

Fouling potential evaluation by cake fouling index : Theoretical development, measurements, and its implications for fouling mechanisms. / Jin, Yongxun; Ju, Younggil; Lee, Hyunkyung; Hong, Seungkwan.

In: Journal of Membrane Science, Vol. 490, 05.09.2015, p. 57-64.

Research output: Contribution to journalArticle

@article{5dd37707401f4cb2a33820cfa6e636cd,
title = "Fouling potential evaluation by cake fouling index: Theoretical development, measurements, and its implications for fouling mechanisms",
abstract = "Current fouling indices typically employed in RO practices, such as silt density index (SDI) and modified fouling index (MFI), have suffered greatly from their inability to predict actual fouling potential primarily due to the erroneous interpretation of fouling mechanisms. Our findings clearly demonstrated that the effect of pore blocking should be excluded during fouling index measurements to simulate real RO applications. Thus, new concept of cake fouling index (CFI) was developed in order to accurately evaluate true fouling cake layer resistance. Specifically, the CFI was determined through consecutive filtration tests by subtracting the flux decline of the secondary filtration from that of the first one to eliminate the effect of pore blocking. The results proved that CFI better predicts the degree of fouling rate in RO experiments than MFI. It was also revealed that it could be utilized as a useful tool for identifying and evaluating the fouling mechanisms. Through a comparison of MFI and CFI, it was shown that pore blocking was enhanced as much as cake formation when pH decreased, while divalent cations (Ca2+) increased only cake formation on the membrane surface. This newly developed index refining existing MFI method is expected to provide more precise information about RO membrane fouling, especially for the design of effective pretreatment processes.",
keywords = "Cake fouling index (CFI), Fouling mechanism, Modified fouling index (MFI), RO membrane fouling, Silt density index (SDI)",
author = "Yongxun Jin and Younggil Ju and Hyunkyung Lee and Seungkwan Hong",
year = "2015",
month = "9",
day = "5",
doi = "10.1016/j.memsci.2015.04.049",
language = "English",
volume = "490",
pages = "57--64",
journal = "Jornal of Membrane Science",
issn = "0376-7388",
publisher = "Elsevier",

}

TY - JOUR

T1 - Fouling potential evaluation by cake fouling index

T2 - Theoretical development, measurements, and its implications for fouling mechanisms

AU - Jin, Yongxun

AU - Ju, Younggil

AU - Lee, Hyunkyung

AU - Hong, Seungkwan

PY - 2015/9/5

Y1 - 2015/9/5

N2 - Current fouling indices typically employed in RO practices, such as silt density index (SDI) and modified fouling index (MFI), have suffered greatly from their inability to predict actual fouling potential primarily due to the erroneous interpretation of fouling mechanisms. Our findings clearly demonstrated that the effect of pore blocking should be excluded during fouling index measurements to simulate real RO applications. Thus, new concept of cake fouling index (CFI) was developed in order to accurately evaluate true fouling cake layer resistance. Specifically, the CFI was determined through consecutive filtration tests by subtracting the flux decline of the secondary filtration from that of the first one to eliminate the effect of pore blocking. The results proved that CFI better predicts the degree of fouling rate in RO experiments than MFI. It was also revealed that it could be utilized as a useful tool for identifying and evaluating the fouling mechanisms. Through a comparison of MFI and CFI, it was shown that pore blocking was enhanced as much as cake formation when pH decreased, while divalent cations (Ca2+) increased only cake formation on the membrane surface. This newly developed index refining existing MFI method is expected to provide more precise information about RO membrane fouling, especially for the design of effective pretreatment processes.

AB - Current fouling indices typically employed in RO practices, such as silt density index (SDI) and modified fouling index (MFI), have suffered greatly from their inability to predict actual fouling potential primarily due to the erroneous interpretation of fouling mechanisms. Our findings clearly demonstrated that the effect of pore blocking should be excluded during fouling index measurements to simulate real RO applications. Thus, new concept of cake fouling index (CFI) was developed in order to accurately evaluate true fouling cake layer resistance. Specifically, the CFI was determined through consecutive filtration tests by subtracting the flux decline of the secondary filtration from that of the first one to eliminate the effect of pore blocking. The results proved that CFI better predicts the degree of fouling rate in RO experiments than MFI. It was also revealed that it could be utilized as a useful tool for identifying and evaluating the fouling mechanisms. Through a comparison of MFI and CFI, it was shown that pore blocking was enhanced as much as cake formation when pH decreased, while divalent cations (Ca2+) increased only cake formation on the membrane surface. This newly developed index refining existing MFI method is expected to provide more precise information about RO membrane fouling, especially for the design of effective pretreatment processes.

KW - Cake fouling index (CFI)

KW - Fouling mechanism

KW - Modified fouling index (MFI)

KW - RO membrane fouling

KW - Silt density index (SDI)

UR - http://www.scopus.com/inward/record.url?scp=84929302489&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84929302489&partnerID=8YFLogxK

U2 - 10.1016/j.memsci.2015.04.049

DO - 10.1016/j.memsci.2015.04.049

M3 - Article

AN - SCOPUS:84929302489

VL - 490

SP - 57

EP - 64

JO - Jornal of Membrane Science

JF - Jornal of Membrane Science

SN - 0376-7388

ER -