Full range, dual depth optical coherence tomography for ophthalmology

Beop-Min Kim, Hyun Woo Jeong, Jeehyun Kim, Sang Won Lee, Wonzoo Chung

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

We present spectral-domain optical coherence tomography (SD-OCT) using a single spectrometer with dual illumination and interlaced detection at 830 nm, which can provide anterior segment and retinal tomograms simultaneously. For the full-range imaging, which is needed especially for the anterior segment imaging, we employed vestigial sideband (VSB) filter for the effective mirror artifact removal during the off-pivot, full-range approach in SD-OCT.

Original languageEnglish
Title of host publicationPacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest
DOIs
Publication statusPublished - 2013 Oct 18
Event10th Conference on Lasers and Electro-Optics Pacific Rim, CLEO-PR 2013 - Kyoto, Japan
Duration: 2013 Jun 302013 Jul 4

Other

Other10th Conference on Lasers and Electro-Optics Pacific Rim, CLEO-PR 2013
CountryJapan
CityKyoto
Period13/6/3013/7/4

Fingerprint

Ophthalmology
ophthalmology
Optical tomography
optical thickness
tomography
pivots
Imaging techniques
sidebands
artifacts
Spectrometers
Mirrors
Lighting
illumination
spectrometers
mirrors
filters

ASJC Scopus subject areas

  • Condensed Matter Physics
  • Atomic and Molecular Physics, and Optics
  • Electronic, Optical and Magnetic Materials
  • Electrical and Electronic Engineering

Cite this

Kim, B-M., Jeong, H. W., Kim, J., Lee, S. W., & Chung, W. (2013). Full range, dual depth optical coherence tomography for ophthalmology. In Pacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest [6600271] https://doi.org/10.1109/CLEOPR.2013.6600271

Full range, dual depth optical coherence tomography for ophthalmology. / Kim, Beop-Min; Jeong, Hyun Woo; Kim, Jeehyun; Lee, Sang Won; Chung, Wonzoo.

Pacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest. 2013. 6600271.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Kim, B-M, Jeong, HW, Kim, J, Lee, SW & Chung, W 2013, Full range, dual depth optical coherence tomography for ophthalmology. in Pacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest., 6600271, 10th Conference on Lasers and Electro-Optics Pacific Rim, CLEO-PR 2013, Kyoto, Japan, 13/6/30. https://doi.org/10.1109/CLEOPR.2013.6600271
Kim B-M, Jeong HW, Kim J, Lee SW, Chung W. Full range, dual depth optical coherence tomography for ophthalmology. In Pacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest. 2013. 6600271 https://doi.org/10.1109/CLEOPR.2013.6600271
Kim, Beop-Min ; Jeong, Hyun Woo ; Kim, Jeehyun ; Lee, Sang Won ; Chung, Wonzoo. / Full range, dual depth optical coherence tomography for ophthalmology. Pacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest. 2013.
@inproceedings{cad7784944b14860adeed1e92fb472f3,
title = "Full range, dual depth optical coherence tomography for ophthalmology",
abstract = "We present spectral-domain optical coherence tomography (SD-OCT) using a single spectrometer with dual illumination and interlaced detection at 830 nm, which can provide anterior segment and retinal tomograms simultaneously. For the full-range imaging, which is needed especially for the anterior segment imaging, we employed vestigial sideband (VSB) filter for the effective mirror artifact removal during the off-pivot, full-range approach in SD-OCT.",
author = "Beop-Min Kim and Jeong, {Hyun Woo} and Jeehyun Kim and Lee, {Sang Won} and Wonzoo Chung",
year = "2013",
month = "10",
day = "18",
doi = "10.1109/CLEOPR.2013.6600271",
language = "English",
isbn = "9781467364751",
booktitle = "Pacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest",

}

TY - GEN

T1 - Full range, dual depth optical coherence tomography for ophthalmology

AU - Kim, Beop-Min

AU - Jeong, Hyun Woo

AU - Kim, Jeehyun

AU - Lee, Sang Won

AU - Chung, Wonzoo

PY - 2013/10/18

Y1 - 2013/10/18

N2 - We present spectral-domain optical coherence tomography (SD-OCT) using a single spectrometer with dual illumination and interlaced detection at 830 nm, which can provide anterior segment and retinal tomograms simultaneously. For the full-range imaging, which is needed especially for the anterior segment imaging, we employed vestigial sideband (VSB) filter for the effective mirror artifact removal during the off-pivot, full-range approach in SD-OCT.

AB - We present spectral-domain optical coherence tomography (SD-OCT) using a single spectrometer with dual illumination and interlaced detection at 830 nm, which can provide anterior segment and retinal tomograms simultaneously. For the full-range imaging, which is needed especially for the anterior segment imaging, we employed vestigial sideband (VSB) filter for the effective mirror artifact removal during the off-pivot, full-range approach in SD-OCT.

UR - http://www.scopus.com/inward/record.url?scp=84885467095&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84885467095&partnerID=8YFLogxK

U2 - 10.1109/CLEOPR.2013.6600271

DO - 10.1109/CLEOPR.2013.6600271

M3 - Conference contribution

AN - SCOPUS:84885467095

SN - 9781467364751

BT - Pacific Rim Conference on Lasers and Electro-Optics, CLEO - Technical Digest

ER -