Immediate loading on mandibular edentulous patient with SFI Bar® overdenture

Ha Young Kim, Ryan Jin Young Kim, Sarah Qadeer, Chang Mo Jeong, Sang-Wan Shin, Jung Bo Huh

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Despite the greater retention and low maintenance of bar attachment system, the longer clinical time and increased number of visits were the assignments to overcome in bar attachment system. This case report describes SFI-Bar® (Cendres et Métaux, Biel/Bienne, Switzerland) to be solve those problems. A 65-year-old female, who had severely absorbed mandible, hoped to wear a stable mandibular denture without pain. As soon as two implants were placed on mandible, a tube bar was connected to two adaptors connected to each implant. The length of the tube bar was adjusted considering inter implant distance, and reconnected to the adaptors. Finally a female part was seated beneath the denture. This case report showed that a satisfactory clinical result was achieved by delivering bar overdenture immediately after implant placement without laboratory procedure.

Original languageEnglish
Pages (from-to)47-50
Number of pages4
JournalJournal of Advanced Prosthodontics
Volume3
Issue number1
DOIs
Publication statusPublished - 2011 Dec 1

Fingerprint

Overlay Denture
Dentures
Mandible
Switzerland
Maintenance
Pain

Keywords

  • Dental implant
  • Immediate loading
  • Overdenture
  • SFI-bar

ASJC Scopus subject areas

  • Dentistry (miscellaneous)
  • Oral Surgery

Cite this

Immediate loading on mandibular edentulous patient with SFI Bar® overdenture. / Kim, Ha Young; Kim, Ryan Jin Young; Qadeer, Sarah; Jeong, Chang Mo; Shin, Sang-Wan; Huh, Jung Bo.

In: Journal of Advanced Prosthodontics, Vol. 3, No. 1, 01.12.2011, p. 47-50.

Research output: Contribution to journalArticle

Kim, Ha Young ; Kim, Ryan Jin Young ; Qadeer, Sarah ; Jeong, Chang Mo ; Shin, Sang-Wan ; Huh, Jung Bo. / Immediate loading on mandibular edentulous patient with SFI Bar® overdenture. In: Journal of Advanced Prosthodontics. 2011 ; Vol. 3, No. 1. pp. 47-50.
@article{565e8965d8e34ccd844568ff15da551d,
title = "Immediate loading on mandibular edentulous patient with SFI Bar{\circledR} overdenture",
abstract = "Despite the greater retention and low maintenance of bar attachment system, the longer clinical time and increased number of visits were the assignments to overcome in bar attachment system. This case report describes SFI-Bar{\circledR} (Cendres et M{\'e}taux, Biel/Bienne, Switzerland) to be solve those problems. A 65-year-old female, who had severely absorbed mandible, hoped to wear a stable mandibular denture without pain. As soon as two implants were placed on mandible, a tube bar was connected to two adaptors connected to each implant. The length of the tube bar was adjusted considering inter implant distance, and reconnected to the adaptors. Finally a female part was seated beneath the denture. This case report showed that a satisfactory clinical result was achieved by delivering bar overdenture immediately after implant placement without laboratory procedure.",
keywords = "Dental implant, Immediate loading, Overdenture, SFI-bar",
author = "Kim, {Ha Young} and Kim, {Ryan Jin Young} and Sarah Qadeer and Jeong, {Chang Mo} and Sang-Wan Shin and Huh, {Jung Bo}",
year = "2011",
month = "12",
day = "1",
doi = "10.4047/jap.2011.3.1.47",
language = "English",
volume = "3",
pages = "47--50",
journal = "Journal of Advanced Prosthodontics",
issn = "2005-7806",
publisher = "The Korean Academy of prosthodontics",
number = "1",

}

TY - JOUR

T1 - Immediate loading on mandibular edentulous patient with SFI Bar® overdenture

AU - Kim, Ha Young

AU - Kim, Ryan Jin Young

AU - Qadeer, Sarah

AU - Jeong, Chang Mo

AU - Shin, Sang-Wan

AU - Huh, Jung Bo

PY - 2011/12/1

Y1 - 2011/12/1

N2 - Despite the greater retention and low maintenance of bar attachment system, the longer clinical time and increased number of visits were the assignments to overcome in bar attachment system. This case report describes SFI-Bar® (Cendres et Métaux, Biel/Bienne, Switzerland) to be solve those problems. A 65-year-old female, who had severely absorbed mandible, hoped to wear a stable mandibular denture without pain. As soon as two implants were placed on mandible, a tube bar was connected to two adaptors connected to each implant. The length of the tube bar was adjusted considering inter implant distance, and reconnected to the adaptors. Finally a female part was seated beneath the denture. This case report showed that a satisfactory clinical result was achieved by delivering bar overdenture immediately after implant placement without laboratory procedure.

AB - Despite the greater retention and low maintenance of bar attachment system, the longer clinical time and increased number of visits were the assignments to overcome in bar attachment system. This case report describes SFI-Bar® (Cendres et Métaux, Biel/Bienne, Switzerland) to be solve those problems. A 65-year-old female, who had severely absorbed mandible, hoped to wear a stable mandibular denture without pain. As soon as two implants were placed on mandible, a tube bar was connected to two adaptors connected to each implant. The length of the tube bar was adjusted considering inter implant distance, and reconnected to the adaptors. Finally a female part was seated beneath the denture. This case report showed that a satisfactory clinical result was achieved by delivering bar overdenture immediately after implant placement without laboratory procedure.

KW - Dental implant

KW - Immediate loading

KW - Overdenture

KW - SFI-bar

UR - http://www.scopus.com/inward/record.url?scp=84883138859&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84883138859&partnerID=8YFLogxK

U2 - 10.4047/jap.2011.3.1.47

DO - 10.4047/jap.2011.3.1.47

M3 - Article

VL - 3

SP - 47

EP - 50

JO - Journal of Advanced Prosthodontics

JF - Journal of Advanced Prosthodontics

SN - 2005-7806

IS - 1

ER -