Improved imaging of the cervico-thoracic junction in computed tomography

Pyong Kon Cho, Young Hen Lee, You Hyun Kim, Jong Hak Choi, Dong Chul Shin, Tae Kyu Choi, Jang Seob Kim, Kihyun Kim, Sun Ung Kim

Research output: Contribution to journalArticle

Abstract

Purpose: To reduce beam hardening artifacts caused by the shoulder joint, we explored new and unique methods to improve the quality of images, such as varying the injection site and changing the position of patients (swimmers position). Materials and Methods: Fifth-four patients underwent neck CT examinations performed in routine and swimmers position and with a 64-slice MDCT scanner in spiral scanning. To examine the difference due to the injection sites of contrast material, subjects were divided into right- and left-side groups. For the evaluation of images, we carried out a subjective and objective assessment based on radiologists' ratings and noise measurement. Results: Images of the lower neck in the swimmers position exhibited less hardening and streak artifacts. The subjective and objective evaluations showed that the swimmers position received higher rating by radiologists and had lower noise level than that of routine position. The swimmers position was the most effective for the diagnosis of the cervico-thoracic junction area. As for the injection site, we obtained better images by an injection of contrast material in the right arm than in the left. Conclusion: CT examination of the lower neck in the swimmers position may improve the quality of image and the effectiveness of diagnosis. The injection of a contrast material to the right side rather than the left side reduced foreign body artifacts.

Original languageEnglish
Pages (from-to)84-89
Number of pages6
JournalYonsei Medical Journal
Volume49
Issue number1
DOIs
Publication statusPublished - 2008 Feb 1

Fingerprint

Thorax
Tomography
Injections
Artifacts
Contrast Media
Neck
Noise
Shoulder Joint
Foreign Bodies
Arm
Radiologists

Keywords

  • Artifacts
  • Cervico-thoracic junction
  • Computed tomography
  • Swimmers position

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Cho, P. K., Lee, Y. H., Kim, Y. H., Choi, J. H., Shin, D. C., Choi, T. K., ... Kim, S. U. (2008). Improved imaging of the cervico-thoracic junction in computed tomography. Yonsei Medical Journal, 49(1), 84-89. https://doi.org/10.3349/ymj.2008.49.1.84

Improved imaging of the cervico-thoracic junction in computed tomography. / Cho, Pyong Kon; Lee, Young Hen; Kim, You Hyun; Choi, Jong Hak; Shin, Dong Chul; Choi, Tae Kyu; Kim, Jang Seob; Kim, Kihyun; Kim, Sun Ung.

In: Yonsei Medical Journal, Vol. 49, No. 1, 01.02.2008, p. 84-89.

Research output: Contribution to journalArticle

Cho, PK, Lee, YH, Kim, YH, Choi, JH, Shin, DC, Choi, TK, Kim, JS, Kim, K & Kim, SU 2008, 'Improved imaging of the cervico-thoracic junction in computed tomography', Yonsei Medical Journal, vol. 49, no. 1, pp. 84-89. https://doi.org/10.3349/ymj.2008.49.1.84
Cho, Pyong Kon ; Lee, Young Hen ; Kim, You Hyun ; Choi, Jong Hak ; Shin, Dong Chul ; Choi, Tae Kyu ; Kim, Jang Seob ; Kim, Kihyun ; Kim, Sun Ung. / Improved imaging of the cervico-thoracic junction in computed tomography. In: Yonsei Medical Journal. 2008 ; Vol. 49, No. 1. pp. 84-89.
@article{ebe46cbd53064d238bf95b7d3027ec53,
title = "Improved imaging of the cervico-thoracic junction in computed tomography",
abstract = "Purpose: To reduce beam hardening artifacts caused by the shoulder joint, we explored new and unique methods to improve the quality of images, such as varying the injection site and changing the position of patients (swimmers position). Materials and Methods: Fifth-four patients underwent neck CT examinations performed in routine and swimmers position and with a 64-slice MDCT scanner in spiral scanning. To examine the difference due to the injection sites of contrast material, subjects were divided into right- and left-side groups. For the evaluation of images, we carried out a subjective and objective assessment based on radiologists' ratings and noise measurement. Results: Images of the lower neck in the swimmers position exhibited less hardening and streak artifacts. The subjective and objective evaluations showed that the swimmers position received higher rating by radiologists and had lower noise level than that of routine position. The swimmers position was the most effective for the diagnosis of the cervico-thoracic junction area. As for the injection site, we obtained better images by an injection of contrast material in the right arm than in the left. Conclusion: CT examination of the lower neck in the swimmers position may improve the quality of image and the effectiveness of diagnosis. The injection of a contrast material to the right side rather than the left side reduced foreign body artifacts.",
keywords = "Artifacts, Cervico-thoracic junction, Computed tomography, Swimmers position",
author = "Cho, {Pyong Kon} and Lee, {Young Hen} and Kim, {You Hyun} and Choi, {Jong Hak} and Shin, {Dong Chul} and Choi, {Tae Kyu} and Kim, {Jang Seob} and Kihyun Kim and Kim, {Sun Ung}",
year = "2008",
month = "2",
day = "1",
doi = "10.3349/ymj.2008.49.1.84",
language = "English",
volume = "49",
pages = "84--89",
journal = "Yonsei Medical Journal",
issn = "0513-5796",
publisher = "Yonsei University College of Medicine",
number = "1",

}

TY - JOUR

T1 - Improved imaging of the cervico-thoracic junction in computed tomography

AU - Cho, Pyong Kon

AU - Lee, Young Hen

AU - Kim, You Hyun

AU - Choi, Jong Hak

AU - Shin, Dong Chul

AU - Choi, Tae Kyu

AU - Kim, Jang Seob

AU - Kim, Kihyun

AU - Kim, Sun Ung

PY - 2008/2/1

Y1 - 2008/2/1

N2 - Purpose: To reduce beam hardening artifacts caused by the shoulder joint, we explored new and unique methods to improve the quality of images, such as varying the injection site and changing the position of patients (swimmers position). Materials and Methods: Fifth-four patients underwent neck CT examinations performed in routine and swimmers position and with a 64-slice MDCT scanner in spiral scanning. To examine the difference due to the injection sites of contrast material, subjects were divided into right- and left-side groups. For the evaluation of images, we carried out a subjective and objective assessment based on radiologists' ratings and noise measurement. Results: Images of the lower neck in the swimmers position exhibited less hardening and streak artifacts. The subjective and objective evaluations showed that the swimmers position received higher rating by radiologists and had lower noise level than that of routine position. The swimmers position was the most effective for the diagnosis of the cervico-thoracic junction area. As for the injection site, we obtained better images by an injection of contrast material in the right arm than in the left. Conclusion: CT examination of the lower neck in the swimmers position may improve the quality of image and the effectiveness of diagnosis. The injection of a contrast material to the right side rather than the left side reduced foreign body artifacts.

AB - Purpose: To reduce beam hardening artifacts caused by the shoulder joint, we explored new and unique methods to improve the quality of images, such as varying the injection site and changing the position of patients (swimmers position). Materials and Methods: Fifth-four patients underwent neck CT examinations performed in routine and swimmers position and with a 64-slice MDCT scanner in spiral scanning. To examine the difference due to the injection sites of contrast material, subjects were divided into right- and left-side groups. For the evaluation of images, we carried out a subjective and objective assessment based on radiologists' ratings and noise measurement. Results: Images of the lower neck in the swimmers position exhibited less hardening and streak artifacts. The subjective and objective evaluations showed that the swimmers position received higher rating by radiologists and had lower noise level than that of routine position. The swimmers position was the most effective for the diagnosis of the cervico-thoracic junction area. As for the injection site, we obtained better images by an injection of contrast material in the right arm than in the left. Conclusion: CT examination of the lower neck in the swimmers position may improve the quality of image and the effectiveness of diagnosis. The injection of a contrast material to the right side rather than the left side reduced foreign body artifacts.

KW - Artifacts

KW - Cervico-thoracic junction

KW - Computed tomography

KW - Swimmers position

UR - http://www.scopus.com/inward/record.url?scp=41949083800&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=41949083800&partnerID=8YFLogxK

U2 - 10.3349/ymj.2008.49.1.84

DO - 10.3349/ymj.2008.49.1.84

M3 - Article

VL - 49

SP - 84

EP - 89

JO - Yonsei Medical Journal

JF - Yonsei Medical Journal

SN - 0513-5796

IS - 1

ER -