Inhalation risk assessment of naphthalene emitted from deodorant balls in public toilets

Yerin Jung, Pil Gon Kim, Jung-Hwan Kwon

Research output: Contribution to journalArticle

Abstract

The inhalation of naphthalene used as deodorant balls in public toilets could be an important cancer risk factor. The atmospheric concentration of naphthalene in public toilets (Cin) was estimated both by a polyurethane foam passive air sampler (PUF-PAS) deployed in nine public toilets in Seoul, Korea and by a steady-state indoor air quality model, including emission estimation using Monte-Carlo simulation. Based on the estimated Cin, cancer risk was also assessed for cleaning workers and the general population. The steady-state Cin estimated using the estimated emission rate, which assumed that air exchange was the only process by which naphthalene was removed, was much greater than the Cin value measured using PUF-PAS in nine public toilets, implying the importance of other removal processes, such as sorption to walls and the garments of visitors, as well as decreased emission rate owing to wetting of the naphthalene ball surface. The 95 percentile values of cancer risk for workers based on the estimation by PUF-PAS was 1.6×10–6, whereas those for the general public were lower than 1×10–6 . The results suggested that naphthalene deodorant balls in public toilets may be an important cancer risk factor especially for the cleaning workers.

Original languageEnglish
Article numbere2019005
JournalEnvironmental Health and Toxicology
Volume34
Issue number2
DOIs
Publication statusPublished - 2019 Jun 1

Fingerprint

Deodorants
Risk assessment
Inhalation
Air
Cleaning
Neoplasms
Indoor Air Pollution
Clothing
Korea
Air quality
Wetting
Sorption
naphthalene
Population
polyurethane foam

Keywords

  • Inhalation exposure
  • Monte-Carlo simulation
  • Naphthalene
  • Polyurethane foam
  • Public toilet
  • Risk assessment

ASJC Scopus subject areas

  • Public Health, Environmental and Occupational Health
  • Health, Toxicology and Mutagenesis
  • Toxicology

Cite this

Inhalation risk assessment of naphthalene emitted from deodorant balls in public toilets. / Jung, Yerin; Kim, Pil Gon; Kwon, Jung-Hwan.

In: Environmental Health and Toxicology, Vol. 34, No. 2, e2019005, 01.06.2019.

Research output: Contribution to journalArticle

@article{955fea58ca49479d8beb8c4180196152,
title = "Inhalation risk assessment of naphthalene emitted from deodorant balls in public toilets",
abstract = "The inhalation of naphthalene used as deodorant balls in public toilets could be an important cancer risk factor. The atmospheric concentration of naphthalene in public toilets (Cin) was estimated both by a polyurethane foam passive air sampler (PUF-PAS) deployed in nine public toilets in Seoul, Korea and by a steady-state indoor air quality model, including emission estimation using Monte-Carlo simulation. Based on the estimated Cin, cancer risk was also assessed for cleaning workers and the general population. The steady-state Cin estimated using the estimated emission rate, which assumed that air exchange was the only process by which naphthalene was removed, was much greater than the Cin value measured using PUF-PAS in nine public toilets, implying the importance of other removal processes, such as sorption to walls and the garments of visitors, as well as decreased emission rate owing to wetting of the naphthalene ball surface. The 95 percentile values of cancer risk for workers based on the estimation by PUF-PAS was 1.6×10–6, whereas those for the general public were lower than 1×10–6 . The results suggested that naphthalene deodorant balls in public toilets may be an important cancer risk factor especially for the cleaning workers.",
keywords = "Inhalation exposure, Monte-Carlo simulation, Naphthalene, Polyurethane foam, Public toilet, Risk assessment",
author = "Yerin Jung and Kim, {Pil Gon} and Jung-Hwan Kwon",
year = "2019",
month = "6",
day = "1",
doi = "10.5620/eht.e2019005",
language = "English",
volume = "34",
journal = "Environmental Health and Toxicology",
issn = "2233-6567",
publisher = "Korean Society of Environmental Health and Toxicology",
number = "2",

}

TY - JOUR

T1 - Inhalation risk assessment of naphthalene emitted from deodorant balls in public toilets

AU - Jung, Yerin

AU - Kim, Pil Gon

AU - Kwon, Jung-Hwan

PY - 2019/6/1

Y1 - 2019/6/1

N2 - The inhalation of naphthalene used as deodorant balls in public toilets could be an important cancer risk factor. The atmospheric concentration of naphthalene in public toilets (Cin) was estimated both by a polyurethane foam passive air sampler (PUF-PAS) deployed in nine public toilets in Seoul, Korea and by a steady-state indoor air quality model, including emission estimation using Monte-Carlo simulation. Based on the estimated Cin, cancer risk was also assessed for cleaning workers and the general population. The steady-state Cin estimated using the estimated emission rate, which assumed that air exchange was the only process by which naphthalene was removed, was much greater than the Cin value measured using PUF-PAS in nine public toilets, implying the importance of other removal processes, such as sorption to walls and the garments of visitors, as well as decreased emission rate owing to wetting of the naphthalene ball surface. The 95 percentile values of cancer risk for workers based on the estimation by PUF-PAS was 1.6×10–6, whereas those for the general public were lower than 1×10–6 . The results suggested that naphthalene deodorant balls in public toilets may be an important cancer risk factor especially for the cleaning workers.

AB - The inhalation of naphthalene used as deodorant balls in public toilets could be an important cancer risk factor. The atmospheric concentration of naphthalene in public toilets (Cin) was estimated both by a polyurethane foam passive air sampler (PUF-PAS) deployed in nine public toilets in Seoul, Korea and by a steady-state indoor air quality model, including emission estimation using Monte-Carlo simulation. Based on the estimated Cin, cancer risk was also assessed for cleaning workers and the general population. The steady-state Cin estimated using the estimated emission rate, which assumed that air exchange was the only process by which naphthalene was removed, was much greater than the Cin value measured using PUF-PAS in nine public toilets, implying the importance of other removal processes, such as sorption to walls and the garments of visitors, as well as decreased emission rate owing to wetting of the naphthalene ball surface. The 95 percentile values of cancer risk for workers based on the estimation by PUF-PAS was 1.6×10–6, whereas those for the general public were lower than 1×10–6 . The results suggested that naphthalene deodorant balls in public toilets may be an important cancer risk factor especially for the cleaning workers.

KW - Inhalation exposure

KW - Monte-Carlo simulation

KW - Naphthalene

KW - Polyurethane foam

KW - Public toilet

KW - Risk assessment

UR - http://www.scopus.com/inward/record.url?scp=85068519010&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85068519010&partnerID=8YFLogxK

U2 - 10.5620/eht.e2019005

DO - 10.5620/eht.e2019005

M3 - Article

AN - SCOPUS:85068519010

VL - 34

JO - Environmental Health and Toxicology

JF - Environmental Health and Toxicology

SN - 2233-6567

IS - 2

M1 - e2019005

ER -