Investigation of detector light response modeling for a thick continuous slab detector

R. S. Miyaoka, Kisung Lee

Research output: Chapter in Book/Report/Conference proceedingConference contribution

5 Citations (Scopus)

Abstract

We investigate a method to improve the position decoding for thick crystal versions (i.e., >8 mm) of our continuous miniature crystal element (cMiCE) PET detector by more accurately modeling the detector's light response function (LRF). The LRF for continuous detectors varies with the depth of interaction (DOI) of the detected photon. This variation of the LRF can result in a positioning error for two-dimensional positioning algorithms. The effect is greatest for photons interacting directly over a PMT channel or near the edge of the crystal. We explore a method to improve positioning performance by deriving two look up tables (LUTs), from the collected data, corresponding to the front and back regions of the crystal. The DETECT2000 simulation package was used to investigate the light response characteristics for a 48.8 mm by 48.8 mm by 10 (8) nun slab of LSO coupled to a 64 channel, flat panel PMT. Using DETECT2000 the light collected for each PMT channel versus interaction location in three dimensions is known. The data are then combined to produce the two dimensional light collection histograms that one would experimentally measure. Light collection histograms that have markedly non-Gaussian distributions (e.g., bimodal or have a high-end tail) are characterized as a combination of two Gaussian functions, where each Gaussian function corresponds to a DOI region of the crystal The results indicate modest gains in positioning accuracy are achieved near the central region of the crystal. However, significant improvements in spatial resolution and positioning bias are achieved for the corner section of the detector.

Original languageEnglish
Title of host publicationIEEE Nuclear Science Symposium Conference Record
EditorsJ.A. Seibert
Pages2479-2482
Number of pages4
Volume4
Publication statusPublished - 2004
Externally publishedYes
Event2004 Nuclear Science Symposium, Medical Imaging Conference, Symposium on Nuclear Power Systems and the 14th International Workshop on Room Temperature Semiconductor X- and Gamma- Ray Detectors - Rome, Italy
Duration: 2004 Oct 162004 Oct 22

Other

Other2004 Nuclear Science Symposium, Medical Imaging Conference, Symposium on Nuclear Power Systems and the 14th International Workshop on Room Temperature Semiconductor X- and Gamma- Ray Detectors
CountryItaly
CityRome
Period04/10/1604/10/22

    Fingerprint

ASJC Scopus subject areas

  • Computer Vision and Pattern Recognition
  • Industrial and Manufacturing Engineering

Cite this

Miyaoka, R. S., & Lee, K. (2004). Investigation of detector light response modeling for a thick continuous slab detector. In J. A. Seibert (Ed.), IEEE Nuclear Science Symposium Conference Record (Vol. 4, pp. 2479-2482)