Solid-state devices to detect photons are under active research and development because they, unlike photomultiplier tubes (PMT), can be used under high-magnetic-field and radio-frequency environments, such as in magnetic resonance imaging (MRI) scanners. In addition, some of the solid-state devices have a higher particle detection efficiency and only a slightly less gain than PMTs, currently the first choice to detect photons in positron emission tomography (PET) scanners. We have tested solid-state photomultipliers (SSPM) among several different solid-state devices in the market. This paper describes the test methods and the characteristics of SSPMs with an emphasis on use in PET scanners. We obtained a 25 % energy resolution and a 4.5-ns time resolution with 22Na and lutetium yttrium oxyorthosilicate (LYSO), both full-width at half maximum (FWHM). The number of fired mini-cells and the amplification factor were, respectively, estimated to be 154 ± 37 for 22Na and (3.8 ± 0.9) × 105. Even though SSPM-LYSO couplings resulted in worse performances than PMT-LYSO couplings, the solid-state devices have good potential for use in the PET scanners, especially in combined PET/MRI scanners because the new solid-state devices appear to have better characteristics, such as a higher quantum efficiency and a larger number of mini-cells, than the tested SSPMs.

Original languageEnglish
Pages (from-to)1332-1339
Number of pages8
JournalJournal of the Korean Physical Society
Volume50
Issue number5
Publication statusPublished - 2007 May 1

Fingerprint

solid state devices
scanners
positrons
tomography
solid state
photomultiplier tubes
magnetic resonance
lutetium
photons
research and development
cells
yttrium
quantum efficiency
radio frequencies
magnetic fields

Keywords

  • Energy resolution
  • LYSO
  • MRI
  • PET
  • Solid-state photomultiplier
  • Time resolution

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

Lee, J. S., Ito, M., Sim, K. S., Hong, B., Lee, K. S., Muhammad, J., ... Hong, S. J. (2007). Investigation of solid-state photomultipliers for positron emission tomography scanners. Journal of the Korean Physical Society, 50(5), 1332-1339.

Investigation of solid-state photomultipliers for positron emission tomography scanners. / Lee, Jae Sung; Ito, Mikiko; Sim, Kwang Souk; Hong, Byungsik; Lee, Kyung Sei; Muhammad, Jamil; Rhee, June Tak; Lee, Geon Song; Park, Kwang Suk; Song, In Chan; Hong, Seong Jong.

In: Journal of the Korean Physical Society, Vol. 50, No. 5, 01.05.2007, p. 1332-1339.

Research output: Contribution to journalArticle

Lee, JS, Ito, M, Sim, KS, Hong, B, Lee, KS, Muhammad, J, Rhee, JT, Lee, GS, Park, KS, Song, IC & Hong, SJ 2007, 'Investigation of solid-state photomultipliers for positron emission tomography scanners', Journal of the Korean Physical Society, vol. 50, no. 5, pp. 1332-1339.
Lee, Jae Sung ; Ito, Mikiko ; Sim, Kwang Souk ; Hong, Byungsik ; Lee, Kyung Sei ; Muhammad, Jamil ; Rhee, June Tak ; Lee, Geon Song ; Park, Kwang Suk ; Song, In Chan ; Hong, Seong Jong. / Investigation of solid-state photomultipliers for positron emission tomography scanners. In: Journal of the Korean Physical Society. 2007 ; Vol. 50, No. 5. pp. 1332-1339.
@article{f241e92648c0468a9040e6e8a14cd576,
title = "Investigation of solid-state photomultipliers for positron emission tomography scanners",
abstract = "Solid-state devices to detect photons are under active research and development because they, unlike photomultiplier tubes (PMT), can be used under high-magnetic-field and radio-frequency environments, such as in magnetic resonance imaging (MRI) scanners. In addition, some of the solid-state devices have a higher particle detection efficiency and only a slightly less gain than PMTs, currently the first choice to detect photons in positron emission tomography (PET) scanners. We have tested solid-state photomultipliers (SSPM) among several different solid-state devices in the market. This paper describes the test methods and the characteristics of SSPMs with an emphasis on use in PET scanners. We obtained a 25 {\%} energy resolution and a 4.5-ns time resolution with 22Na and lutetium yttrium oxyorthosilicate (LYSO), both full-width at half maximum (FWHM). The number of fired mini-cells and the amplification factor were, respectively, estimated to be 154 ± 37 for 22Na and (3.8 ± 0.9) × 105. Even though SSPM-LYSO couplings resulted in worse performances than PMT-LYSO couplings, the solid-state devices have good potential for use in the PET scanners, especially in combined PET/MRI scanners because the new solid-state devices appear to have better characteristics, such as a higher quantum efficiency and a larger number of mini-cells, than the tested SSPMs.",
keywords = "Energy resolution, LYSO, MRI, PET, Solid-state photomultiplier, Time resolution",
author = "Lee, {Jae Sung} and Mikiko Ito and Sim, {Kwang Souk} and Byungsik Hong and Lee, {Kyung Sei} and Jamil Muhammad and Rhee, {June Tak} and Lee, {Geon Song} and Park, {Kwang Suk} and Song, {In Chan} and Hong, {Seong Jong}",
year = "2007",
month = "5",
day = "1",
language = "English",
volume = "50",
pages = "1332--1339",
journal = "Journal of the Korean Physical Society",
issn = "0374-4884",
publisher = "Korean Physical Society",
number = "5",

}

TY - JOUR

T1 - Investigation of solid-state photomultipliers for positron emission tomography scanners

AU - Lee, Jae Sung

AU - Ito, Mikiko

AU - Sim, Kwang Souk

AU - Hong, Byungsik

AU - Lee, Kyung Sei

AU - Muhammad, Jamil

AU - Rhee, June Tak

AU - Lee, Geon Song

AU - Park, Kwang Suk

AU - Song, In Chan

AU - Hong, Seong Jong

PY - 2007/5/1

Y1 - 2007/5/1

N2 - Solid-state devices to detect photons are under active research and development because they, unlike photomultiplier tubes (PMT), can be used under high-magnetic-field and radio-frequency environments, such as in magnetic resonance imaging (MRI) scanners. In addition, some of the solid-state devices have a higher particle detection efficiency and only a slightly less gain than PMTs, currently the first choice to detect photons in positron emission tomography (PET) scanners. We have tested solid-state photomultipliers (SSPM) among several different solid-state devices in the market. This paper describes the test methods and the characteristics of SSPMs with an emphasis on use in PET scanners. We obtained a 25 % energy resolution and a 4.5-ns time resolution with 22Na and lutetium yttrium oxyorthosilicate (LYSO), both full-width at half maximum (FWHM). The number of fired mini-cells and the amplification factor were, respectively, estimated to be 154 ± 37 for 22Na and (3.8 ± 0.9) × 105. Even though SSPM-LYSO couplings resulted in worse performances than PMT-LYSO couplings, the solid-state devices have good potential for use in the PET scanners, especially in combined PET/MRI scanners because the new solid-state devices appear to have better characteristics, such as a higher quantum efficiency and a larger number of mini-cells, than the tested SSPMs.

AB - Solid-state devices to detect photons are under active research and development because they, unlike photomultiplier tubes (PMT), can be used under high-magnetic-field and radio-frequency environments, such as in magnetic resonance imaging (MRI) scanners. In addition, some of the solid-state devices have a higher particle detection efficiency and only a slightly less gain than PMTs, currently the first choice to detect photons in positron emission tomography (PET) scanners. We have tested solid-state photomultipliers (SSPM) among several different solid-state devices in the market. This paper describes the test methods and the characteristics of SSPMs with an emphasis on use in PET scanners. We obtained a 25 % energy resolution and a 4.5-ns time resolution with 22Na and lutetium yttrium oxyorthosilicate (LYSO), both full-width at half maximum (FWHM). The number of fired mini-cells and the amplification factor were, respectively, estimated to be 154 ± 37 for 22Na and (3.8 ± 0.9) × 105. Even though SSPM-LYSO couplings resulted in worse performances than PMT-LYSO couplings, the solid-state devices have good potential for use in the PET scanners, especially in combined PET/MRI scanners because the new solid-state devices appear to have better characteristics, such as a higher quantum efficiency and a larger number of mini-cells, than the tested SSPMs.

KW - Energy resolution

KW - LYSO

KW - MRI

KW - PET

KW - Solid-state photomultiplier

KW - Time resolution

UR - http://www.scopus.com/inward/record.url?scp=34250156727&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34250156727&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:34250156727

VL - 50

SP - 1332

EP - 1339

JO - Journal of the Korean Physical Society

JF - Journal of the Korean Physical Society

SN - 0374-4884

IS - 5

ER -