In spite of continuous increase of electric power demand and new generation plants, it is very difficult to install new transmission line. Therefore, it comes to be difficult to operate the power system stable, so it is required to find another way to get new transmission capacity. Because HVDC transmission system installation is the one of the best option for us, we have undertake the HVDC project in mainland. Buckdangjin-Goduck HVDC project(500kV, 3GW) is currently under construction and Eastern Power HVDC project(500kV, 8GW) is under the study for technical specification. Both of them have the Run-up SPS function for taking action of 765kV Transmission line fault. The Run-up SPS function increases the active power output of the HVDC rapidly when the transmission line between the power plant and network is tripped, thereby preventing the generator from overspeed and improving the power system stability. In this paper, we propose MEAC(Modified Equal Area Criteria) method based on traditional EAC method to quantitatively evaluate the effect of the HVDC run-up SPS function on the power system stability improvement.

Original languageEnglish
Pages (from-to)1454-1459
Number of pages6
JournalTransactions of the Korean Institute of Electrical Engineers
Volume66
Issue number10
DOIs
Publication statusPublished - 2017 Jan 1

Fingerprint

System stability
Electric lines
Power plants
Specifications

Keywords

  • HVDC
  • MEAC
  • Power system stability
  • Run-up
  • SPS

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

MEAC method for analysis of power system stability improving effect considering run-up SPS function of HVDC. / Lee, Jae Gul; Song, Ji Young; Jang, Gilsoo.

In: Transactions of the Korean Institute of Electrical Engineers, Vol. 66, No. 10, 01.01.2017, p. 1454-1459.

Research output: Contribution to journalArticle

@article{53451d11d54243ca9dd226122e701bda,
title = "MEAC method for analysis of power system stability improving effect considering run-up SPS function of HVDC",
abstract = "In spite of continuous increase of electric power demand and new generation plants, it is very difficult to install new transmission line. Therefore, it comes to be difficult to operate the power system stable, so it is required to find another way to get new transmission capacity. Because HVDC transmission system installation is the one of the best option for us, we have undertake the HVDC project in mainland. Buckdangjin-Goduck HVDC project(500kV, 3GW) is currently under construction and Eastern Power HVDC project(500kV, 8GW) is under the study for technical specification. Both of them have the Run-up SPS function for taking action of 765kV Transmission line fault. The Run-up SPS function increases the active power output of the HVDC rapidly when the transmission line between the power plant and network is tripped, thereby preventing the generator from overspeed and improving the power system stability. In this paper, we propose MEAC(Modified Equal Area Criteria) method based on traditional EAC method to quantitatively evaluate the effect of the HVDC run-up SPS function on the power system stability improvement.",
keywords = "HVDC, MEAC, Power system stability, Run-up, SPS",
author = "Lee, {Jae Gul} and Song, {Ji Young} and Gilsoo Jang",
year = "2017",
month = "1",
day = "1",
doi = "10.5370/KIEE.2017.66.10.1454",
language = "English",
volume = "66",
pages = "1454--1459",
journal = "Transactions of the Korean Institute of Electrical Engineers",
issn = "1975-8359",
publisher = "Korean Institute of Electrical Engineers",
number = "10",

}

TY - JOUR

T1 - MEAC method for analysis of power system stability improving effect considering run-up SPS function of HVDC

AU - Lee, Jae Gul

AU - Song, Ji Young

AU - Jang, Gilsoo

PY - 2017/1/1

Y1 - 2017/1/1

N2 - In spite of continuous increase of electric power demand and new generation plants, it is very difficult to install new transmission line. Therefore, it comes to be difficult to operate the power system stable, so it is required to find another way to get new transmission capacity. Because HVDC transmission system installation is the one of the best option for us, we have undertake the HVDC project in mainland. Buckdangjin-Goduck HVDC project(500kV, 3GW) is currently under construction and Eastern Power HVDC project(500kV, 8GW) is under the study for technical specification. Both of them have the Run-up SPS function for taking action of 765kV Transmission line fault. The Run-up SPS function increases the active power output of the HVDC rapidly when the transmission line between the power plant and network is tripped, thereby preventing the generator from overspeed and improving the power system stability. In this paper, we propose MEAC(Modified Equal Area Criteria) method based on traditional EAC method to quantitatively evaluate the effect of the HVDC run-up SPS function on the power system stability improvement.

AB - In spite of continuous increase of electric power demand and new generation plants, it is very difficult to install new transmission line. Therefore, it comes to be difficult to operate the power system stable, so it is required to find another way to get new transmission capacity. Because HVDC transmission system installation is the one of the best option for us, we have undertake the HVDC project in mainland. Buckdangjin-Goduck HVDC project(500kV, 3GW) is currently under construction and Eastern Power HVDC project(500kV, 8GW) is under the study for technical specification. Both of them have the Run-up SPS function for taking action of 765kV Transmission line fault. The Run-up SPS function increases the active power output of the HVDC rapidly when the transmission line between the power plant and network is tripped, thereby preventing the generator from overspeed and improving the power system stability. In this paper, we propose MEAC(Modified Equal Area Criteria) method based on traditional EAC method to quantitatively evaluate the effect of the HVDC run-up SPS function on the power system stability improvement.

KW - HVDC

KW - MEAC

KW - Power system stability

KW - Run-up

KW - SPS

UR - http://www.scopus.com/inward/record.url?scp=85040174387&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85040174387&partnerID=8YFLogxK

U2 - 10.5370/KIEE.2017.66.10.1454

DO - 10.5370/KIEE.2017.66.10.1454

M3 - Article

AN - SCOPUS:85040174387

VL - 66

SP - 1454

EP - 1459

JO - Transactions of the Korean Institute of Electrical Engineers

JF - Transactions of the Korean Institute of Electrical Engineers

SN - 1975-8359

IS - 10

ER -