Abstract

Using electromagnetic levitation in combination with the oscillating drop technique, the surface tension of liquid Fe-20 wt.% Cu alloy above and below the liquidus temperature was measured. The containerless state during levitation produces substantial undercooling up to 156 K. In the experimentally covered temperature range, the surface tension of Fe-20 wt.% Cu alloy was determined as 1.658-2.234 × 10-4 (T-1736) N/m. According to Butler's equation and STCBE software, the surface tension of Fe-20 wt.% Cu alloy was also calculated. A good agreement was found between the calculated and experimentally measured values within the error limits. The different sign of the temperature dependences of the calculated and measured surface tensions is preliminarily discussed.

Original languageEnglish
Pages (from-to)1001-1004
Number of pages4
JournalZeitschrift fuer Metallkunde/Materials Research and Advanced Techniques
Volume95
Issue number11
Publication statusPublished - 2004 Nov 1
Externally publishedYes

Fingerprint

Surface tension
interfacial tension
Liquids
liquids
magnetic suspension
Undercooling
levitation
liquidus
supercooling
Temperature
computer programs
temperature dependence
temperature

Keywords

  • Fe-Cu alloy
  • Surface tension
  • Undercooled liquid

ASJC Scopus subject areas

  • Metals and Alloys

Cite this

Measurement and calculation of surface tension of undercooled liquid Fe-20 wt.% Cu alloy. / Xu, Jun; Qiao, Zhiyu; Han, Xiujun; Wei, Bingbo; Lee, Joonho; Tanaka, Toshihiro.

In: Zeitschrift fuer Metallkunde/Materials Research and Advanced Techniques, Vol. 95, No. 11, 01.11.2004, p. 1001-1004.

Research output: Contribution to journalArticle

Xu, Jun ; Qiao, Zhiyu ; Han, Xiujun ; Wei, Bingbo ; Lee, Joonho ; Tanaka, Toshihiro. / Measurement and calculation of surface tension of undercooled liquid Fe-20 wt.% Cu alloy. In: Zeitschrift fuer Metallkunde/Materials Research and Advanced Techniques. 2004 ; Vol. 95, No. 11. pp. 1001-1004.
@article{0c4f360d138c4aec9c26d7ba6ff33e5f,
title = "Measurement and calculation of surface tension of undercooled liquid Fe-20 wt.{\%} Cu alloy",
abstract = "Using electromagnetic levitation in combination with the oscillating drop technique, the surface tension of liquid Fe-20 wt.{\%} Cu alloy above and below the liquidus temperature was measured. The containerless state during levitation produces substantial undercooling up to 156 K. In the experimentally covered temperature range, the surface tension of Fe-20 wt.{\%} Cu alloy was determined as 1.658-2.234 × 10-4 (T-1736) N/m. According to Butler's equation and STCBE software, the surface tension of Fe-20 wt.{\%} Cu alloy was also calculated. A good agreement was found between the calculated and experimentally measured values within the error limits. The different sign of the temperature dependences of the calculated and measured surface tensions is preliminarily discussed.",
keywords = "Fe-Cu alloy, Surface tension, Undercooled liquid",
author = "Jun Xu and Zhiyu Qiao and Xiujun Han and Bingbo Wei and Joonho Lee and Toshihiro Tanaka",
year = "2004",
month = "11",
day = "1",
language = "English",
volume = "95",
pages = "1001--1004",
journal = "International Journal of Materials Research",
issn = "1862-5282",
publisher = "Carl Hanser Verlag GmbH & Co. KG",
number = "11",

}

TY - JOUR

T1 - Measurement and calculation of surface tension of undercooled liquid Fe-20 wt.% Cu alloy

AU - Xu, Jun

AU - Qiao, Zhiyu

AU - Han, Xiujun

AU - Wei, Bingbo

AU - Lee, Joonho

AU - Tanaka, Toshihiro

PY - 2004/11/1

Y1 - 2004/11/1

N2 - Using electromagnetic levitation in combination with the oscillating drop technique, the surface tension of liquid Fe-20 wt.% Cu alloy above and below the liquidus temperature was measured. The containerless state during levitation produces substantial undercooling up to 156 K. In the experimentally covered temperature range, the surface tension of Fe-20 wt.% Cu alloy was determined as 1.658-2.234 × 10-4 (T-1736) N/m. According to Butler's equation and STCBE software, the surface tension of Fe-20 wt.% Cu alloy was also calculated. A good agreement was found between the calculated and experimentally measured values within the error limits. The different sign of the temperature dependences of the calculated and measured surface tensions is preliminarily discussed.

AB - Using electromagnetic levitation in combination with the oscillating drop technique, the surface tension of liquid Fe-20 wt.% Cu alloy above and below the liquidus temperature was measured. The containerless state during levitation produces substantial undercooling up to 156 K. In the experimentally covered temperature range, the surface tension of Fe-20 wt.% Cu alloy was determined as 1.658-2.234 × 10-4 (T-1736) N/m. According to Butler's equation and STCBE software, the surface tension of Fe-20 wt.% Cu alloy was also calculated. A good agreement was found between the calculated and experimentally measured values within the error limits. The different sign of the temperature dependences of the calculated and measured surface tensions is preliminarily discussed.

KW - Fe-Cu alloy

KW - Surface tension

KW - Undercooled liquid

UR - http://www.scopus.com/inward/record.url?scp=9144220222&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=9144220222&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:9144220222

VL - 95

SP - 1001

EP - 1004

JO - International Journal of Materials Research

JF - International Journal of Materials Research

SN - 1862-5282

IS - 11

ER -