We have measured the gas bremsstrahlung photon energy from the 2.5-GeV electron storage ring at the Pohang Light Source (PLS). Gas bremsstrahlung was generated in the straight section of the beam-diagnosis beamline 1C1 with an effective length of 5.3 m. We present the measurement results for the bremsstrahlung photon energy spectrum and the photon flux, which were obtained by using a CeF 3 calorimeter, The calorimeter consisted of nine CeF 3 blocks, each being 3.3 × 3.3 × 33 cm 3, stacked into a 3 × 3 array. The bremsstrahlung photon flux above 40 MeV was measured to be 218 s -1 at an electron beam current of 180 mA.

Original languageEnglish
Pages (from-to)788-792
Number of pages5
JournalJournal of the Korean Physical Society
Volume47
Issue number5
Publication statusPublished - 2005 Nov 1
Externally publishedYes

Fingerprint

bremsstrahlung
scintillation counters
light sources
photons
gases
calorimeters
beam currents
energy spectra
electron beams
electrons
energy

Keywords

  • CeF
  • Electron storage ring
  • Gas bremsstrahlung
  • PLS

ASJC Scopus subject areas

  • Physics and Astronomy(all)

Cite this

Measurement of gas bremsstrahlung at the pohang light source by using a CeF 3 scintillator. / Park, J. Y.; Hwang, S. H.; Ahn, Jung Keun; Kim, E. S.; Han, Y. J.

In: Journal of the Korean Physical Society, Vol. 47, No. 5, 01.11.2005, p. 788-792.

Research output: Contribution to journalArticle

Park, J. Y. ; Hwang, S. H. ; Ahn, Jung Keun ; Kim, E. S. ; Han, Y. J. / Measurement of gas bremsstrahlung at the pohang light source by using a CeF 3 scintillator. In: Journal of the Korean Physical Society. 2005 ; Vol. 47, No. 5. pp. 788-792.
@article{e9829d4a3f5d44be88f8f0c6a33321db,
title = "Measurement of gas bremsstrahlung at the pohang light source by using a CeF 3 scintillator",
abstract = "We have measured the gas bremsstrahlung photon energy from the 2.5-GeV electron storage ring at the Pohang Light Source (PLS). Gas bremsstrahlung was generated in the straight section of the beam-diagnosis beamline 1C1 with an effective length of 5.3 m. We present the measurement results for the bremsstrahlung photon energy spectrum and the photon flux, which were obtained by using a CeF 3 calorimeter, The calorimeter consisted of nine CeF 3 blocks, each being 3.3 × 3.3 × 33 cm 3, stacked into a 3 × 3 array. The bremsstrahlung photon flux above 40 MeV was measured to be 218 s -1 at an electron beam current of 180 mA.",
keywords = "CeF, Electron storage ring, Gas bremsstrahlung, PLS",
author = "Park, {J. Y.} and Hwang, {S. H.} and Ahn, {Jung Keun} and Kim, {E. S.} and Han, {Y. J.}",
year = "2005",
month = "11",
day = "1",
language = "English",
volume = "47",
pages = "788--792",
journal = "Journal of the Korean Physical Society",
issn = "0374-4884",
publisher = "Korean Physical Society",
number = "5",

}

TY - JOUR

T1 - Measurement of gas bremsstrahlung at the pohang light source by using a CeF 3 scintillator

AU - Park, J. Y.

AU - Hwang, S. H.

AU - Ahn, Jung Keun

AU - Kim, E. S.

AU - Han, Y. J.

PY - 2005/11/1

Y1 - 2005/11/1

N2 - We have measured the gas bremsstrahlung photon energy from the 2.5-GeV electron storage ring at the Pohang Light Source (PLS). Gas bremsstrahlung was generated in the straight section of the beam-diagnosis beamline 1C1 with an effective length of 5.3 m. We present the measurement results for the bremsstrahlung photon energy spectrum and the photon flux, which were obtained by using a CeF 3 calorimeter, The calorimeter consisted of nine CeF 3 blocks, each being 3.3 × 3.3 × 33 cm 3, stacked into a 3 × 3 array. The bremsstrahlung photon flux above 40 MeV was measured to be 218 s -1 at an electron beam current of 180 mA.

AB - We have measured the gas bremsstrahlung photon energy from the 2.5-GeV electron storage ring at the Pohang Light Source (PLS). Gas bremsstrahlung was generated in the straight section of the beam-diagnosis beamline 1C1 with an effective length of 5.3 m. We present the measurement results for the bremsstrahlung photon energy spectrum and the photon flux, which were obtained by using a CeF 3 calorimeter, The calorimeter consisted of nine CeF 3 blocks, each being 3.3 × 3.3 × 33 cm 3, stacked into a 3 × 3 array. The bremsstrahlung photon flux above 40 MeV was measured to be 218 s -1 at an electron beam current of 180 mA.

KW - CeF

KW - Electron storage ring

KW - Gas bremsstrahlung

KW - PLS

UR - http://www.scopus.com/inward/record.url?scp=28744444470&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=28744444470&partnerID=8YFLogxK

M3 - Article

VL - 47

SP - 788

EP - 792

JO - Journal of the Korean Physical Society

JF - Journal of the Korean Physical Society

SN - 0374-4884

IS - 5

ER -