Microchip-based cell aggregometer using stirring-disaggregation mechanism

Sehyun Shin, Yijie Yang, Jang Soo Suh

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

A new microchip-based aggregometer that uses a stirring-aided disaggregation mechanism in a microchip was developed to measure red blood cell (RBC) aggregation in blood and RBC suspensions. Conventional methods of RBC disaggregation, such as the rotational Couette system, were replaced with a newly designed stirring-induced disaggregation mechanism. Using a stirrer in a microchip, the aggregated RBCs stored in a microchip can be easily disaggregated. With an abrupt halt of the stirring, the backscattered light intensity can be measured in a microchip with respect to time. The time recording of the backscattered light intensity (syllectogram) shows an exponential decreasing curve representing the RBC aggregation. By analyzing the syllectogram, aggregation indices such as AI and M were determined. The results showed excellent agreement with LORCA. The essential feature of this design is the incorporation of a disposable microchip and the stirring-induced disaggregation mechanism.

Original languageEnglish
Pages (from-to)109-115
Number of pages7
JournalKorea Australia Rheology Journal
Volume19
Issue number3
Publication statusPublished - 2007 Nov 1

Fingerprint

erythrocytes
stirring
Blood
cells
Agglomeration
luminous intensity
blood
recording
Suspensions
Cells
curves

Keywords

  • Aggregation
  • Aggregometer, stirring
  • Microchip
  • RBC

ASJC Scopus subject areas

  • Fluid Flow and Transfer Processes

Cite this

Microchip-based cell aggregometer using stirring-disaggregation mechanism. / Shin, Sehyun; Yang, Yijie; Suh, Jang Soo.

In: Korea Australia Rheology Journal, Vol. 19, No. 3, 01.11.2007, p. 109-115.

Research output: Contribution to journalArticle

@article{83b938728dd340a8a4f243d5d9220e30,
title = "Microchip-based cell aggregometer using stirring-disaggregation mechanism",
abstract = "A new microchip-based aggregometer that uses a stirring-aided disaggregation mechanism in a microchip was developed to measure red blood cell (RBC) aggregation in blood and RBC suspensions. Conventional methods of RBC disaggregation, such as the rotational Couette system, were replaced with a newly designed stirring-induced disaggregation mechanism. Using a stirrer in a microchip, the aggregated RBCs stored in a microchip can be easily disaggregated. With an abrupt halt of the stirring, the backscattered light intensity can be measured in a microchip with respect to time. The time recording of the backscattered light intensity (syllectogram) shows an exponential decreasing curve representing the RBC aggregation. By analyzing the syllectogram, aggregation indices such as AI and M were determined. The results showed excellent agreement with LORCA. The essential feature of this design is the incorporation of a disposable microchip and the stirring-induced disaggregation mechanism.",
keywords = "Aggregation, Aggregometer, stirring, Microchip, RBC",
author = "Sehyun Shin and Yijie Yang and Suh, {Jang Soo}",
year = "2007",
month = "11",
day = "1",
language = "English",
volume = "19",
pages = "109--115",
journal = "Korea Australia Rheology Journal",
issn = "1226-119X",
publisher = "The Korean Society of Rheology",
number = "3",

}

TY - JOUR

T1 - Microchip-based cell aggregometer using stirring-disaggregation mechanism

AU - Shin, Sehyun

AU - Yang, Yijie

AU - Suh, Jang Soo

PY - 2007/11/1

Y1 - 2007/11/1

N2 - A new microchip-based aggregometer that uses a stirring-aided disaggregation mechanism in a microchip was developed to measure red blood cell (RBC) aggregation in blood and RBC suspensions. Conventional methods of RBC disaggregation, such as the rotational Couette system, were replaced with a newly designed stirring-induced disaggregation mechanism. Using a stirrer in a microchip, the aggregated RBCs stored in a microchip can be easily disaggregated. With an abrupt halt of the stirring, the backscattered light intensity can be measured in a microchip with respect to time. The time recording of the backscattered light intensity (syllectogram) shows an exponential decreasing curve representing the RBC aggregation. By analyzing the syllectogram, aggregation indices such as AI and M were determined. The results showed excellent agreement with LORCA. The essential feature of this design is the incorporation of a disposable microchip and the stirring-induced disaggregation mechanism.

AB - A new microchip-based aggregometer that uses a stirring-aided disaggregation mechanism in a microchip was developed to measure red blood cell (RBC) aggregation in blood and RBC suspensions. Conventional methods of RBC disaggregation, such as the rotational Couette system, were replaced with a newly designed stirring-induced disaggregation mechanism. Using a stirrer in a microchip, the aggregated RBCs stored in a microchip can be easily disaggregated. With an abrupt halt of the stirring, the backscattered light intensity can be measured in a microchip with respect to time. The time recording of the backscattered light intensity (syllectogram) shows an exponential decreasing curve representing the RBC aggregation. By analyzing the syllectogram, aggregation indices such as AI and M were determined. The results showed excellent agreement with LORCA. The essential feature of this design is the incorporation of a disposable microchip and the stirring-induced disaggregation mechanism.

KW - Aggregation

KW - Aggregometer, stirring

KW - Microchip

KW - RBC

UR - http://www.scopus.com/inward/record.url?scp=43449115401&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=43449115401&partnerID=8YFLogxK

M3 - Article

VL - 19

SP - 109

EP - 115

JO - Korea Australia Rheology Journal

JF - Korea Australia Rheology Journal

SN - 1226-119X

IS - 3

ER -