Microfluidic chip-based electrochemical immunoassay for hippuric acid

Sung Ju Yoo, Young Bong Choi, Jong Il Ju, Gun Sik Tae, Hyug Han Kim, Sang Hoon Lee

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

Urinary hippuric acid (HA), of molecular weight 180 Da, is one of the major metabolites in toluene-exposed humans and is a major biological indicator. Simple and ubiquitous monitoring of exposure to toluene is very important in occupational health care, and a microfluidic chip-based electrochemical immunoassay for rapid and quantitative detection of HA in human urine is proposed in this paper. The system employs a conjugate of ferrocene (Fc) and hippuric acid (HA). The competition between hippuric acid (HA) and the ferrocene-hippuric acid complex (Fc-Lys-HA) to bind with a HA antibody coated onto polybeads generated electrical signals proportional to the HA concentration in the range of 0-40 mg mL-1. All the complicated HA detection processes were integrated on the single microfluidic platform. The quantitative advantages of our HA detection chip are as follows: (1) the total chip size was reduced to 3.0 × 2.0 × 0.5 cm and is small enough to be portable, (2) the assay time took 1 min, and is shorter than that of conventional electrochemical HA immunoassay systems (about 20 min) and (3) 40 μL of the sample solution was enough to detect HA in the range of 0-40 mg mL-1, which is enough range to be used for the point-of-care system. In addition, we suggest the improved chip-based HA assay method by the combination of electrochemical and enzymatic amplification processes for the detection of greater electrical signals. The sensitivity of the combined method was increased about three times compared to that of the non-enzymatic process.

Original languageEnglish
Pages (from-to)2462-2467
Number of pages6
JournalAnalyst
Volume134
Issue number12
DOIs
Publication statusPublished - 2009 Dec 28

Fingerprint

Microfluidics
immunoassay
Immunoassay
Acids
acid
Toluene
hippuric acid
toluene
Assays
Point-of-Care Systems
assay
Occupational Health
Metabolites
bioindicator
Health care
Antibodies
urine
antibody
Amplification
amplification

ASJC Scopus subject areas

  • Analytical Chemistry
  • Spectroscopy
  • Electrochemistry
  • Biochemistry
  • Environmental Chemistry

Cite this

Yoo, S. J., Choi, Y. B., Ju, J. I., Tae, G. S., Kim, H. H., & Lee, S. H. (2009). Microfluidic chip-based electrochemical immunoassay for hippuric acid. Analyst, 134(12), 2462-2467. https://doi.org/10.1039/b915356j

Microfluidic chip-based electrochemical immunoassay for hippuric acid. / Yoo, Sung Ju; Choi, Young Bong; Ju, Jong Il; Tae, Gun Sik; Kim, Hyug Han; Lee, Sang Hoon.

In: Analyst, Vol. 134, No. 12, 28.12.2009, p. 2462-2467.

Research output: Contribution to journalArticle

Yoo, SJ, Choi, YB, Ju, JI, Tae, GS, Kim, HH & Lee, SH 2009, 'Microfluidic chip-based electrochemical immunoassay for hippuric acid', Analyst, vol. 134, no. 12, pp. 2462-2467. https://doi.org/10.1039/b915356j
Yoo, Sung Ju ; Choi, Young Bong ; Ju, Jong Il ; Tae, Gun Sik ; Kim, Hyug Han ; Lee, Sang Hoon. / Microfluidic chip-based electrochemical immunoassay for hippuric acid. In: Analyst. 2009 ; Vol. 134, No. 12. pp. 2462-2467.
@article{891137b4fd5241089d11949df8135677,
title = "Microfluidic chip-based electrochemical immunoassay for hippuric acid",
abstract = "Urinary hippuric acid (HA), of molecular weight 180 Da, is one of the major metabolites in toluene-exposed humans and is a major biological indicator. Simple and ubiquitous monitoring of exposure to toluene is very important in occupational health care, and a microfluidic chip-based electrochemical immunoassay for rapid and quantitative detection of HA in human urine is proposed in this paper. The system employs a conjugate of ferrocene (Fc) and hippuric acid (HA). The competition between hippuric acid (HA) and the ferrocene-hippuric acid complex (Fc-Lys-HA) to bind with a HA antibody coated onto polybeads generated electrical signals proportional to the HA concentration in the range of 0-40 mg mL-1. All the complicated HA detection processes were integrated on the single microfluidic platform. The quantitative advantages of our HA detection chip are as follows: (1) the total chip size was reduced to 3.0 × 2.0 × 0.5 cm and is small enough to be portable, (2) the assay time took 1 min, and is shorter than that of conventional electrochemical HA immunoassay systems (about 20 min) and (3) 40 μL of the sample solution was enough to detect HA in the range of 0-40 mg mL-1, which is enough range to be used for the point-of-care system. In addition, we suggest the improved chip-based HA assay method by the combination of electrochemical and enzymatic amplification processes for the detection of greater electrical signals. The sensitivity of the combined method was increased about three times compared to that of the non-enzymatic process.",
author = "Yoo, {Sung Ju} and Choi, {Young Bong} and Ju, {Jong Il} and Tae, {Gun Sik} and Kim, {Hyug Han} and Lee, {Sang Hoon}",
year = "2009",
month = "12",
day = "28",
doi = "10.1039/b915356j",
language = "English",
volume = "134",
pages = "2462--2467",
journal = "The Analyst",
issn = "0003-2654",
publisher = "Royal Society of Chemistry",
number = "12",

}

TY - JOUR

T1 - Microfluidic chip-based electrochemical immunoassay for hippuric acid

AU - Yoo, Sung Ju

AU - Choi, Young Bong

AU - Ju, Jong Il

AU - Tae, Gun Sik

AU - Kim, Hyug Han

AU - Lee, Sang Hoon

PY - 2009/12/28

Y1 - 2009/12/28

N2 - Urinary hippuric acid (HA), of molecular weight 180 Da, is one of the major metabolites in toluene-exposed humans and is a major biological indicator. Simple and ubiquitous monitoring of exposure to toluene is very important in occupational health care, and a microfluidic chip-based electrochemical immunoassay for rapid and quantitative detection of HA in human urine is proposed in this paper. The system employs a conjugate of ferrocene (Fc) and hippuric acid (HA). The competition between hippuric acid (HA) and the ferrocene-hippuric acid complex (Fc-Lys-HA) to bind with a HA antibody coated onto polybeads generated electrical signals proportional to the HA concentration in the range of 0-40 mg mL-1. All the complicated HA detection processes were integrated on the single microfluidic platform. The quantitative advantages of our HA detection chip are as follows: (1) the total chip size was reduced to 3.0 × 2.0 × 0.5 cm and is small enough to be portable, (2) the assay time took 1 min, and is shorter than that of conventional electrochemical HA immunoassay systems (about 20 min) and (3) 40 μL of the sample solution was enough to detect HA in the range of 0-40 mg mL-1, which is enough range to be used for the point-of-care system. In addition, we suggest the improved chip-based HA assay method by the combination of electrochemical and enzymatic amplification processes for the detection of greater electrical signals. The sensitivity of the combined method was increased about three times compared to that of the non-enzymatic process.

AB - Urinary hippuric acid (HA), of molecular weight 180 Da, is one of the major metabolites in toluene-exposed humans and is a major biological indicator. Simple and ubiquitous monitoring of exposure to toluene is very important in occupational health care, and a microfluidic chip-based electrochemical immunoassay for rapid and quantitative detection of HA in human urine is proposed in this paper. The system employs a conjugate of ferrocene (Fc) and hippuric acid (HA). The competition between hippuric acid (HA) and the ferrocene-hippuric acid complex (Fc-Lys-HA) to bind with a HA antibody coated onto polybeads generated electrical signals proportional to the HA concentration in the range of 0-40 mg mL-1. All the complicated HA detection processes were integrated on the single microfluidic platform. The quantitative advantages of our HA detection chip are as follows: (1) the total chip size was reduced to 3.0 × 2.0 × 0.5 cm and is small enough to be portable, (2) the assay time took 1 min, and is shorter than that of conventional electrochemical HA immunoassay systems (about 20 min) and (3) 40 μL of the sample solution was enough to detect HA in the range of 0-40 mg mL-1, which is enough range to be used for the point-of-care system. In addition, we suggest the improved chip-based HA assay method by the combination of electrochemical and enzymatic amplification processes for the detection of greater electrical signals. The sensitivity of the combined method was increased about three times compared to that of the non-enzymatic process.

UR - http://www.scopus.com/inward/record.url?scp=72449157117&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=72449157117&partnerID=8YFLogxK

U2 - 10.1039/b915356j

DO - 10.1039/b915356j

M3 - Article

C2 - 19918618

AN - SCOPUS:72449157117

VL - 134

SP - 2462

EP - 2467

JO - The Analyst

JF - The Analyst

SN - 0003-2654

IS - 12

ER -