Monitoring the dose distribution of therapeutic photons on Korean Typical Man-2 phantom (KTMAN-2) by using multiple-scattering Compton camera

Taewoong Lee, Won Ho Lee

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

This study estimated the performance of a multiple-scattering Compton camera (MSCC) in monitoring the dose distribution of therapeutic photons on a Korean Typical Man-2 (KTMAN-2) phantom. The MSCC was constructed with two CZT semiconductor detectors as scatter detectors and a CWO scintillator detector as an absorber detector. The two planar semiconductor arrays consisted of 40 × 40 pixels, each with a size of 1 × 1 × 10 mm3, and the other CWO array consisted of 40 × 40 pixels, each with a size of 1 × 1 × 10 mm3. The optimized designed parameters such as an inter-detector distance of 3 cm, and a detector thickness of 1cm, were used in this system. The distance between the phantom and first scattering detector was wet to 17 cm to maximize the detection efficiency for scattered photons. When 6-MV photons interacted with voxel in the KTMAN phantom, some photons deposited part of their energy on the voxels and scattered out of the KTMAN phantom. The 3D distribution of therapeutic photons detected by MSCC was simulated by using a Monte Carlo simulation. The reconstructed Compton images were combined with the cross-sectional images of the phantom, and all combined images were well-matched with the predetermined conditions of the simulation. Our simulation showed the feasibility of using the Compton imaging to monitor the 3D interaction position in 3D radiation therapy.

Original languageEnglish
Title of host publication2014 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014
PublisherInstitute of Electrical and Electronics Engineers Inc.
ISBN (Print)9781479960972
DOIs
Publication statusPublished - 2016 Mar 10
EventIEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014 - Seattle, United States
Duration: 2014 Nov 82014 Nov 15

Other

OtherIEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014
CountryUnited States
CitySeattle
Period14/11/814/11/15

Fingerprint

Photons
cameras
dosage
detectors
photons
scattering
Semiconductors
Therapeutics
pixels
simulation
Radiotherapy
scintillation counters
radiation therapy
absorbers
interactions

ASJC Scopus subject areas

  • Nuclear and High Energy Physics
  • Radiology Nuclear Medicine and imaging

Cite this

Lee, T., & Lee, W. H. (2016). Monitoring the dose distribution of therapeutic photons on Korean Typical Man-2 phantom (KTMAN-2) by using multiple-scattering Compton camera. In 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014 [7431277] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/NSSMIC.2014.7431277

Monitoring the dose distribution of therapeutic photons on Korean Typical Man-2 phantom (KTMAN-2) by using multiple-scattering Compton camera. / Lee, Taewoong; Lee, Won Ho.

2014 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014. Institute of Electrical and Electronics Engineers Inc., 2016. 7431277.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Lee, T & Lee, WH 2016, Monitoring the dose distribution of therapeutic photons on Korean Typical Man-2 phantom (KTMAN-2) by using multiple-scattering Compton camera. in 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014., 7431277, Institute of Electrical and Electronics Engineers Inc., IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014, Seattle, United States, 14/11/8. https://doi.org/10.1109/NSSMIC.2014.7431277
Lee T, Lee WH. Monitoring the dose distribution of therapeutic photons on Korean Typical Man-2 phantom (KTMAN-2) by using multiple-scattering Compton camera. In 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014. Institute of Electrical and Electronics Engineers Inc. 2016. 7431277 https://doi.org/10.1109/NSSMIC.2014.7431277
Lee, Taewoong ; Lee, Won Ho. / Monitoring the dose distribution of therapeutic photons on Korean Typical Man-2 phantom (KTMAN-2) by using multiple-scattering Compton camera. 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014. Institute of Electrical and Electronics Engineers Inc., 2016.
@inproceedings{6f59d6d73c7a4735870bbfe9f043a161,
title = "Monitoring the dose distribution of therapeutic photons on Korean Typical Man-2 phantom (KTMAN-2) by using multiple-scattering Compton camera",
abstract = "This study estimated the performance of a multiple-scattering Compton camera (MSCC) in monitoring the dose distribution of therapeutic photons on a Korean Typical Man-2 (KTMAN-2) phantom. The MSCC was constructed with two CZT semiconductor detectors as scatter detectors and a CWO scintillator detector as an absorber detector. The two planar semiconductor arrays consisted of 40 × 40 pixels, each with a size of 1 × 1 × 10 mm3, and the other CWO array consisted of 40 × 40 pixels, each with a size of 1 × 1 × 10 mm3. The optimized designed parameters such as an inter-detector distance of 3 cm, and a detector thickness of 1cm, were used in this system. The distance between the phantom and first scattering detector was wet to 17 cm to maximize the detection efficiency for scattered photons. When 6-MV photons interacted with voxel in the KTMAN phantom, some photons deposited part of their energy on the voxels and scattered out of the KTMAN phantom. The 3D distribution of therapeutic photons detected by MSCC was simulated by using a Monte Carlo simulation. The reconstructed Compton images were combined with the cross-sectional images of the phantom, and all combined images were well-matched with the predetermined conditions of the simulation. Our simulation showed the feasibility of using the Compton imaging to monitor the 3D interaction position in 3D radiation therapy.",
author = "Taewoong Lee and Lee, {Won Ho}",
year = "2016",
month = "3",
day = "10",
doi = "10.1109/NSSMIC.2014.7431277",
language = "English",
isbn = "9781479960972",
booktitle = "2014 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - Monitoring the dose distribution of therapeutic photons on Korean Typical Man-2 phantom (KTMAN-2) by using multiple-scattering Compton camera

AU - Lee, Taewoong

AU - Lee, Won Ho

PY - 2016/3/10

Y1 - 2016/3/10

N2 - This study estimated the performance of a multiple-scattering Compton camera (MSCC) in monitoring the dose distribution of therapeutic photons on a Korean Typical Man-2 (KTMAN-2) phantom. The MSCC was constructed with two CZT semiconductor detectors as scatter detectors and a CWO scintillator detector as an absorber detector. The two planar semiconductor arrays consisted of 40 × 40 pixels, each with a size of 1 × 1 × 10 mm3, and the other CWO array consisted of 40 × 40 pixels, each with a size of 1 × 1 × 10 mm3. The optimized designed parameters such as an inter-detector distance of 3 cm, and a detector thickness of 1cm, were used in this system. The distance between the phantom and first scattering detector was wet to 17 cm to maximize the detection efficiency for scattered photons. When 6-MV photons interacted with voxel in the KTMAN phantom, some photons deposited part of their energy on the voxels and scattered out of the KTMAN phantom. The 3D distribution of therapeutic photons detected by MSCC was simulated by using a Monte Carlo simulation. The reconstructed Compton images were combined with the cross-sectional images of the phantom, and all combined images were well-matched with the predetermined conditions of the simulation. Our simulation showed the feasibility of using the Compton imaging to monitor the 3D interaction position in 3D radiation therapy.

AB - This study estimated the performance of a multiple-scattering Compton camera (MSCC) in monitoring the dose distribution of therapeutic photons on a Korean Typical Man-2 (KTMAN-2) phantom. The MSCC was constructed with two CZT semiconductor detectors as scatter detectors and a CWO scintillator detector as an absorber detector. The two planar semiconductor arrays consisted of 40 × 40 pixels, each with a size of 1 × 1 × 10 mm3, and the other CWO array consisted of 40 × 40 pixels, each with a size of 1 × 1 × 10 mm3. The optimized designed parameters such as an inter-detector distance of 3 cm, and a detector thickness of 1cm, were used in this system. The distance between the phantom and first scattering detector was wet to 17 cm to maximize the detection efficiency for scattered photons. When 6-MV photons interacted with voxel in the KTMAN phantom, some photons deposited part of their energy on the voxels and scattered out of the KTMAN phantom. The 3D distribution of therapeutic photons detected by MSCC was simulated by using a Monte Carlo simulation. The reconstructed Compton images were combined with the cross-sectional images of the phantom, and all combined images were well-matched with the predetermined conditions of the simulation. Our simulation showed the feasibility of using the Compton imaging to monitor the 3D interaction position in 3D radiation therapy.

UR - http://www.scopus.com/inward/record.url?scp=84965003005&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84965003005&partnerID=8YFLogxK

U2 - 10.1109/NSSMIC.2014.7431277

DO - 10.1109/NSSMIC.2014.7431277

M3 - Conference contribution

AN - SCOPUS:84965003005

SN - 9781479960972

BT - 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2014

PB - Institute of Electrical and Electronics Engineers Inc.

ER -