Multiplexed detection of pathogens using magnetic microparticles encoded by magnetic axes

Ji Hyun Kim, Young Ki Hahn, Honggu Chun

Research output: Contribution to journalArticle

Abstract

Pathogenic diseases caused by bacteria, viruses and fungi have become an important global public health concern. Rapid, simple, and accurate detection methods are urgently needed for in-field screening of such pathogens. We developed a sensing method based on microparticles encoded by axes of aligned superparamagnetic nanoparticles (SMNPs) to concurrently detect various pathogens. The encoded microparticles, which were fabricated using photocurable polymer and SMNPs, were arranged according to the respective direction of the external magnetic field. By measuring their respective tilted angles, the microparticles can be decoded and used for multiplexed assays. To verify this multiplexing capability, we simultaneously assayed four types of pathogens: Bacillus subtillis, Salmonella typhimurium, Staphylococcus aureus and Escherichia coli O157:H7. The microparticles, conjugated with corresponding capture antibodies, were used, and the concentrations of target pathogens were analyzed with a single-color fluorescent label. The total assay time was as short as 35 min with 200 μl of sample volume and the achieved limit-of-detections (measured signal-to-noise ratio > 3) were as low as 10 CFU ml−1 for Bacillus subtillis, Salmonella typhimurium, Staphylococcus aureus and 100 CFU ml−1 for Escherichia coli O157:H7, respectively. This sensing method represents a promising tool for preventing various diseases by rapid detection of multiple pathogens.

Original languageEnglish
Pages (from-to)11-16
Number of pages6
JournalSensors and Actuators, B: Chemical
Volume285
DOIs
Publication statusPublished - 2019 Apr 15

Fingerprint

pathogens
microparticles
Pathogens
salmonella
Salmonella
staphylococcus
Bacillus
Bacilli
Escherichia
Escherichia coli
Assays
Nanoparticles
public health
nanoparticles
fungi
viruses
Public health
Fungi
antibodies
Viruses

Keywords

  • Early diagnosis
  • Encoded particle
  • Multiplexed assays
  • Pathogen detection
  • Superparamagnetic nanoparticle

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Instrumentation
  • Condensed Matter Physics
  • Surfaces, Coatings and Films
  • Metals and Alloys
  • Electrical and Electronic Engineering
  • Materials Chemistry

Cite this

Multiplexed detection of pathogens using magnetic microparticles encoded by magnetic axes. / Kim, Ji Hyun; Hahn, Young Ki; Chun, Honggu.

In: Sensors and Actuators, B: Chemical, Vol. 285, 15.04.2019, p. 11-16.

Research output: Contribution to journalArticle

@article{22ea23efd0134c38948d3209c6c3eca3,
title = "Multiplexed detection of pathogens using magnetic microparticles encoded by magnetic axes",
abstract = "Pathogenic diseases caused by bacteria, viruses and fungi have become an important global public health concern. Rapid, simple, and accurate detection methods are urgently needed for in-field screening of such pathogens. We developed a sensing method based on microparticles encoded by axes of aligned superparamagnetic nanoparticles (SMNPs) to concurrently detect various pathogens. The encoded microparticles, which were fabricated using photocurable polymer and SMNPs, were arranged according to the respective direction of the external magnetic field. By measuring their respective tilted angles, the microparticles can be decoded and used for multiplexed assays. To verify this multiplexing capability, we simultaneously assayed four types of pathogens: Bacillus subtillis, Salmonella typhimurium, Staphylococcus aureus and Escherichia coli O157:H7. The microparticles, conjugated with corresponding capture antibodies, were used, and the concentrations of target pathogens were analyzed with a single-color fluorescent label. The total assay time was as short as 35 min with 200 μl of sample volume and the achieved limit-of-detections (measured signal-to-noise ratio > 3) were as low as 10 CFU ml−1 for Bacillus subtillis, Salmonella typhimurium, Staphylococcus aureus and 100 CFU ml−1 for Escherichia coli O157:H7, respectively. This sensing method represents a promising tool for preventing various diseases by rapid detection of multiple pathogens.",
keywords = "Early diagnosis, Encoded particle, Multiplexed assays, Pathogen detection, Superparamagnetic nanoparticle",
author = "Kim, {Ji Hyun} and Hahn, {Young Ki} and Honggu Chun",
year = "2019",
month = "4",
day = "15",
doi = "10.1016/j.snb.2019.01.030",
language = "English",
volume = "285",
pages = "11--16",
journal = "Sensors and Actuators, B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",

}

TY - JOUR

T1 - Multiplexed detection of pathogens using magnetic microparticles encoded by magnetic axes

AU - Kim, Ji Hyun

AU - Hahn, Young Ki

AU - Chun, Honggu

PY - 2019/4/15

Y1 - 2019/4/15

N2 - Pathogenic diseases caused by bacteria, viruses and fungi have become an important global public health concern. Rapid, simple, and accurate detection methods are urgently needed for in-field screening of such pathogens. We developed a sensing method based on microparticles encoded by axes of aligned superparamagnetic nanoparticles (SMNPs) to concurrently detect various pathogens. The encoded microparticles, which were fabricated using photocurable polymer and SMNPs, were arranged according to the respective direction of the external magnetic field. By measuring their respective tilted angles, the microparticles can be decoded and used for multiplexed assays. To verify this multiplexing capability, we simultaneously assayed four types of pathogens: Bacillus subtillis, Salmonella typhimurium, Staphylococcus aureus and Escherichia coli O157:H7. The microparticles, conjugated with corresponding capture antibodies, were used, and the concentrations of target pathogens were analyzed with a single-color fluorescent label. The total assay time was as short as 35 min with 200 μl of sample volume and the achieved limit-of-detections (measured signal-to-noise ratio > 3) were as low as 10 CFU ml−1 for Bacillus subtillis, Salmonella typhimurium, Staphylococcus aureus and 100 CFU ml−1 for Escherichia coli O157:H7, respectively. This sensing method represents a promising tool for preventing various diseases by rapid detection of multiple pathogens.

AB - Pathogenic diseases caused by bacteria, viruses and fungi have become an important global public health concern. Rapid, simple, and accurate detection methods are urgently needed for in-field screening of such pathogens. We developed a sensing method based on microparticles encoded by axes of aligned superparamagnetic nanoparticles (SMNPs) to concurrently detect various pathogens. The encoded microparticles, which were fabricated using photocurable polymer and SMNPs, were arranged according to the respective direction of the external magnetic field. By measuring their respective tilted angles, the microparticles can be decoded and used for multiplexed assays. To verify this multiplexing capability, we simultaneously assayed four types of pathogens: Bacillus subtillis, Salmonella typhimurium, Staphylococcus aureus and Escherichia coli O157:H7. The microparticles, conjugated with corresponding capture antibodies, were used, and the concentrations of target pathogens were analyzed with a single-color fluorescent label. The total assay time was as short as 35 min with 200 μl of sample volume and the achieved limit-of-detections (measured signal-to-noise ratio > 3) were as low as 10 CFU ml−1 for Bacillus subtillis, Salmonella typhimurium, Staphylococcus aureus and 100 CFU ml−1 for Escherichia coli O157:H7, respectively. This sensing method represents a promising tool for preventing various diseases by rapid detection of multiple pathogens.

KW - Early diagnosis

KW - Encoded particle

KW - Multiplexed assays

KW - Pathogen detection

KW - Superparamagnetic nanoparticle

UR - http://www.scopus.com/inward/record.url?scp=85059822020&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85059822020&partnerID=8YFLogxK

U2 - 10.1016/j.snb.2019.01.030

DO - 10.1016/j.snb.2019.01.030

M3 - Article

VL - 285

SP - 11

EP - 16

JO - Sensors and Actuators, B: Chemical

JF - Sensors and Actuators, B: Chemical

SN - 0925-4005

ER -