We developed needle-based navigation system for sacral nerve stimulation. Inserting stimulation electrode into the foramen of the sacrum by trocar needle is a very challenging surgical technique. Skin-to-target path and real-time instrument guidance were provided by the designed software interface based on the pre-operative 3D model from 1.25 mm-sliced CT data. Using an electromagnetic navigation system, instrumented 18g needles were inserted into the target position in a dummy. The registration error between the CT coordinate and the electromagnetic tracking coordinate was 0.87 mm in the dummy. Seven nonexperts operated for 10 attempts on each subject, and conventional operation method was also tested by the same non-experts for comparing the accuracy assessment. The mean distance between the needle tip position and the center of the target in a virtual environment was 2.9±1.3 mm (n=70) in the navigation system, and was 8.7±4.1 mm (n=70) in the conventional operation method. The developed navigation system allows the instrument insertion into the target position precisely.

Original languageEnglish
Pages (from-to)271-274
Number of pages4
JournalIFMBE Proceedings
Volume37
DOIs
Publication statusPublished - 2011 Nov 9

Fingerprint

Navigation systems
Needles
Virtual reality
Skin
Electrodes

Keywords

  • electromagnetic tracking
  • navigation
  • needle insertion
  • sacral nerve stimulation

ASJC Scopus subject areas

  • Biomedical Engineering
  • Bioengineering

Cite this

Needle-based intervention for sacral nerve stimulation using electromagnetic tracking and virtual images. / Na, Youngjin; Kim, Yeongjin; Seo, Jong Mo; Jang, Hoon Ah; Park, Jae Young; Lee, Jeong Gu; Kim, Jung.

In: IFMBE Proceedings, Vol. 37, 09.11.2011, p. 271-274.

Research output: Contribution to journalArticle

Na, Youngjin ; Kim, Yeongjin ; Seo, Jong Mo ; Jang, Hoon Ah ; Park, Jae Young ; Lee, Jeong Gu ; Kim, Jung. / Needle-based intervention for sacral nerve stimulation using electromagnetic tracking and virtual images. In: IFMBE Proceedings. 2011 ; Vol. 37. pp. 271-274.
@article{0016d561f62a4b87ba855e5454063423,
title = "Needle-based intervention for sacral nerve stimulation using electromagnetic tracking and virtual images",
abstract = "We developed needle-based navigation system for sacral nerve stimulation. Inserting stimulation electrode into the foramen of the sacrum by trocar needle is a very challenging surgical technique. Skin-to-target path and real-time instrument guidance were provided by the designed software interface based on the pre-operative 3D model from 1.25 mm-sliced CT data. Using an electromagnetic navigation system, instrumented 18g needles were inserted into the target position in a dummy. The registration error between the CT coordinate and the electromagnetic tracking coordinate was 0.87 mm in the dummy. Seven nonexperts operated for 10 attempts on each subject, and conventional operation method was also tested by the same non-experts for comparing the accuracy assessment. The mean distance between the needle tip position and the center of the target in a virtual environment was 2.9±1.3 mm (n=70) in the navigation system, and was 8.7±4.1 mm (n=70) in the conventional operation method. The developed navigation system allows the instrument insertion into the target position precisely.",
keywords = "electromagnetic tracking, navigation, needle insertion, sacral nerve stimulation",
author = "Youngjin Na and Yeongjin Kim and Seo, {Jong Mo} and Jang, {Hoon Ah} and Park, {Jae Young} and Lee, {Jeong Gu} and Jung Kim",
year = "2011",
month = "11",
day = "9",
doi = "10.1007/978-3-642-23508-5_71",
language = "English",
volume = "37",
pages = "271--274",
journal = "IFMBE Proceedings",
issn = "1680-0737",
publisher = "Springer Verlag",

}

TY - JOUR

T1 - Needle-based intervention for sacral nerve stimulation using electromagnetic tracking and virtual images

AU - Na, Youngjin

AU - Kim, Yeongjin

AU - Seo, Jong Mo

AU - Jang, Hoon Ah

AU - Park, Jae Young

AU - Lee, Jeong Gu

AU - Kim, Jung

PY - 2011/11/9

Y1 - 2011/11/9

N2 - We developed needle-based navigation system for sacral nerve stimulation. Inserting stimulation electrode into the foramen of the sacrum by trocar needle is a very challenging surgical technique. Skin-to-target path and real-time instrument guidance were provided by the designed software interface based on the pre-operative 3D model from 1.25 mm-sliced CT data. Using an electromagnetic navigation system, instrumented 18g needles were inserted into the target position in a dummy. The registration error between the CT coordinate and the electromagnetic tracking coordinate was 0.87 mm in the dummy. Seven nonexperts operated for 10 attempts on each subject, and conventional operation method was also tested by the same non-experts for comparing the accuracy assessment. The mean distance between the needle tip position and the center of the target in a virtual environment was 2.9±1.3 mm (n=70) in the navigation system, and was 8.7±4.1 mm (n=70) in the conventional operation method. The developed navigation system allows the instrument insertion into the target position precisely.

AB - We developed needle-based navigation system for sacral nerve stimulation. Inserting stimulation electrode into the foramen of the sacrum by trocar needle is a very challenging surgical technique. Skin-to-target path and real-time instrument guidance were provided by the designed software interface based on the pre-operative 3D model from 1.25 mm-sliced CT data. Using an electromagnetic navigation system, instrumented 18g needles were inserted into the target position in a dummy. The registration error between the CT coordinate and the electromagnetic tracking coordinate was 0.87 mm in the dummy. Seven nonexperts operated for 10 attempts on each subject, and conventional operation method was also tested by the same non-experts for comparing the accuracy assessment. The mean distance between the needle tip position and the center of the target in a virtual environment was 2.9±1.3 mm (n=70) in the navigation system, and was 8.7±4.1 mm (n=70) in the conventional operation method. The developed navigation system allows the instrument insertion into the target position precisely.

KW - electromagnetic tracking

KW - navigation

KW - needle insertion

KW - sacral nerve stimulation

UR - http://www.scopus.com/inward/record.url?scp=80455127368&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80455127368&partnerID=8YFLogxK

U2 - 10.1007/978-3-642-23508-5_71

DO - 10.1007/978-3-642-23508-5_71

M3 - Article

VL - 37

SP - 271

EP - 274

JO - IFMBE Proceedings

JF - IFMBE Proceedings

SN - 1680-0737

ER -