Non-electrical powered continuous cell concentration for enumeration of residual white blood cells in WBC-depleted blood using a viscoelastic fluid

Jeonghun Nam, Woong Sik Jang, Chae Seung Lim

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

White blood cells (WBCs) are one of the critical components whose number has to be reduced before blood transfusion, failing which adverse transfusion effects may occur in patients. However, due to the extremely low concentration of residual WBCs (r-WBCs) in WBC-depleted blood, it is difficult to quantify r-WBCs accurately without using expensive and voluminous instruments. Therefore, the development of a continuous cell concentration technique is required to produce a countable number of cells from rare cells, which cannot normally be detected. In this paper, we present a viscoelastic microfluidic device for sheathless, continuous concentration of WBCs. The device performance was evaluated using polystyrene particles with different sizes at various flow rate conditions in a non-Newtonian fluid compared to a Newtonian fluid. Large particles with a blockage ratio higher than 0.1 were tightly focused at the center and collected at the center outlet with a 98% collection ratio. Meanwhile, the viscosity effect of lysed blood samples with various hematocrits was considered. Finally, diluted WBCs with various dilution ratios were concentrated by ~18-fold and continuous concentration of WBCs in lysed blood samples was performed using a non-electrical powered hand pump sprayer. Without using an external power source, center-focused WBCs were collected at the center outlet at approximately 150 μl/min and the final number of WBCs was increased to 1.8 × 104 cells/ml from undetectable levels.

Original languageEnglish
Pages (from-to)12-19
Number of pages8
JournalTalanta
Volume197
DOIs
Publication statusPublished - 2019 May 15

Fingerprint

Leukocytes
Blood
Cells
Fluids
Lab-On-A-Chip Devices
Electric Power Supplies
Polystyrenes
Hematocrit
Viscosity
Blood Transfusion
Hand
Cell Count
Microfluidics
Equipment and Supplies
Dilution
Flow rate
Pumps

Keywords

  • Blood transfusion
  • Continuous concentration
  • Leuko-depletion
  • Non-electrical powered
  • Residual white blood cells
  • Viscoelastic non-Newtonian fluid

ASJC Scopus subject areas

  • Analytical Chemistry
  • Chemistry(all)
  • Biochemistry
  • Spectroscopy

Cite this

Non-electrical powered continuous cell concentration for enumeration of residual white blood cells in WBC-depleted blood using a viscoelastic fluid. / Nam, Jeonghun; Jang, Woong Sik; Lim, Chae Seung.

In: Talanta, Vol. 197, 15.05.2019, p. 12-19.

Research output: Contribution to journalArticle

@article{edd1f4aa80c14b6691edb0e755ce7291,
title = "Non-electrical powered continuous cell concentration for enumeration of residual white blood cells in WBC-depleted blood using a viscoelastic fluid",
abstract = "White blood cells (WBCs) are one of the critical components whose number has to be reduced before blood transfusion, failing which adverse transfusion effects may occur in patients. However, due to the extremely low concentration of residual WBCs (r-WBCs) in WBC-depleted blood, it is difficult to quantify r-WBCs accurately without using expensive and voluminous instruments. Therefore, the development of a continuous cell concentration technique is required to produce a countable number of cells from rare cells, which cannot normally be detected. In this paper, we present a viscoelastic microfluidic device for sheathless, continuous concentration of WBCs. The device performance was evaluated using polystyrene particles with different sizes at various flow rate conditions in a non-Newtonian fluid compared to a Newtonian fluid. Large particles with a blockage ratio higher than 0.1 were tightly focused at the center and collected at the center outlet with a 98{\%} collection ratio. Meanwhile, the viscosity effect of lysed blood samples with various hematocrits was considered. Finally, diluted WBCs with various dilution ratios were concentrated by ~18-fold and continuous concentration of WBCs in lysed blood samples was performed using a non-electrical powered hand pump sprayer. Without using an external power source, center-focused WBCs were collected at the center outlet at approximately 150 μl/min and the final number of WBCs was increased to 1.8 × 104 cells/ml from undetectable levels.",
keywords = "Blood transfusion, Continuous concentration, Leuko-depletion, Non-electrical powered, Residual white blood cells, Viscoelastic non-Newtonian fluid",
author = "Jeonghun Nam and Jang, {Woong Sik} and Lim, {Chae Seung}",
year = "2019",
month = "5",
day = "15",
doi = "10.1016/j.talanta.2018.12.102",
language = "English",
volume = "197",
pages = "12--19",
journal = "Talanta",
issn = "0039-9140",
publisher = "Elsevier",

}

TY - JOUR

T1 - Non-electrical powered continuous cell concentration for enumeration of residual white blood cells in WBC-depleted blood using a viscoelastic fluid

AU - Nam, Jeonghun

AU - Jang, Woong Sik

AU - Lim, Chae Seung

PY - 2019/5/15

Y1 - 2019/5/15

N2 - White blood cells (WBCs) are one of the critical components whose number has to be reduced before blood transfusion, failing which adverse transfusion effects may occur in patients. However, due to the extremely low concentration of residual WBCs (r-WBCs) in WBC-depleted blood, it is difficult to quantify r-WBCs accurately without using expensive and voluminous instruments. Therefore, the development of a continuous cell concentration technique is required to produce a countable number of cells from rare cells, which cannot normally be detected. In this paper, we present a viscoelastic microfluidic device for sheathless, continuous concentration of WBCs. The device performance was evaluated using polystyrene particles with different sizes at various flow rate conditions in a non-Newtonian fluid compared to a Newtonian fluid. Large particles with a blockage ratio higher than 0.1 were tightly focused at the center and collected at the center outlet with a 98% collection ratio. Meanwhile, the viscosity effect of lysed blood samples with various hematocrits was considered. Finally, diluted WBCs with various dilution ratios were concentrated by ~18-fold and continuous concentration of WBCs in lysed blood samples was performed using a non-electrical powered hand pump sprayer. Without using an external power source, center-focused WBCs were collected at the center outlet at approximately 150 μl/min and the final number of WBCs was increased to 1.8 × 104 cells/ml from undetectable levels.

AB - White blood cells (WBCs) are one of the critical components whose number has to be reduced before blood transfusion, failing which adverse transfusion effects may occur in patients. However, due to the extremely low concentration of residual WBCs (r-WBCs) in WBC-depleted blood, it is difficult to quantify r-WBCs accurately without using expensive and voluminous instruments. Therefore, the development of a continuous cell concentration technique is required to produce a countable number of cells from rare cells, which cannot normally be detected. In this paper, we present a viscoelastic microfluidic device for sheathless, continuous concentration of WBCs. The device performance was evaluated using polystyrene particles with different sizes at various flow rate conditions in a non-Newtonian fluid compared to a Newtonian fluid. Large particles with a blockage ratio higher than 0.1 were tightly focused at the center and collected at the center outlet with a 98% collection ratio. Meanwhile, the viscosity effect of lysed blood samples with various hematocrits was considered. Finally, diluted WBCs with various dilution ratios were concentrated by ~18-fold and continuous concentration of WBCs in lysed blood samples was performed using a non-electrical powered hand pump sprayer. Without using an external power source, center-focused WBCs were collected at the center outlet at approximately 150 μl/min and the final number of WBCs was increased to 1.8 × 104 cells/ml from undetectable levels.

KW - Blood transfusion

KW - Continuous concentration

KW - Leuko-depletion

KW - Non-electrical powered

KW - Residual white blood cells

KW - Viscoelastic non-Newtonian fluid

UR - http://www.scopus.com/inward/record.url?scp=85059570816&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85059570816&partnerID=8YFLogxK

U2 - 10.1016/j.talanta.2018.12.102

DO - 10.1016/j.talanta.2018.12.102

M3 - Article

C2 - 30771912

AN - SCOPUS:85059570816

VL - 197

SP - 12

EP - 19

JO - Talanta

JF - Talanta

SN - 0039-9140

ER -