Numerical and experimental study of falling film in ammonia absorption refrigeration systems

Chan H. Lee, Yong Tae Kang, Hyun U. Kang, Sung Hyun Kim

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

A shell-and-tube absorber and an ammonia absorption refrigeration (AAR) system were constructed to study falling film absorption on a horizontal tube. An empirical and numerical combined method (ENCM) was devloped to estimate the actual falling film thickness using parametric analysis with a simplified mathematical falling film model and experimental results. Numerical and experimental studies showed that the simplified mathematical falling film model has an exact physical response about ammonia absorption process in the absorber. The temperature difference of solution decreases with the increasing inlet coolant temperature. The heat transfer performance of a real type shell-and-tube absorber with the AAR system is a more sensitive function of the coolant inlet temperature than the solution inlet temperature, The ENCM developed in the present study can be used to estimate the actual thickness of a falling film along a horizontal tube in the shell-and-tube absorber of the AAR system, which is very diflicult to measure experimentally. The ammonia absorption rate decreases with inlet temperature cf a weak ammonia solution and inlet coolant temperature.

Original languageEnglish
Pages (from-to)520-527
Number of pages8
JournalJournal of Chemical Engineering of Japan
Volume38
Issue number7
DOIs
Publication statusPublished - 2005 Nov 9

Fingerprint

Absorption refrigeration
Ammonia
Coolants
Temperature
Film thickness
Heat transfer

Keywords

  • AAR system
  • Absorber
  • Ammonia absorption
  • Heat and mass transfer
  • Shell-and-tube

ASJC Scopus subject areas

  • Chemical Engineering(all)

Cite this

Numerical and experimental study of falling film in ammonia absorption refrigeration systems. / Lee, Chan H.; Kang, Yong Tae; Kang, Hyun U.; Kim, Sung Hyun.

In: Journal of Chemical Engineering of Japan, Vol. 38, No. 7, 09.11.2005, p. 520-527.

Research output: Contribution to journalArticle

@article{cdefc4bb0b1541fea6e8681cd6fd4d23,
title = "Numerical and experimental study of falling film in ammonia absorption refrigeration systems",
abstract = "A shell-and-tube absorber and an ammonia absorption refrigeration (AAR) system were constructed to study falling film absorption on a horizontal tube. An empirical and numerical combined method (ENCM) was devloped to estimate the actual falling film thickness using parametric analysis with a simplified mathematical falling film model and experimental results. Numerical and experimental studies showed that the simplified mathematical falling film model has an exact physical response about ammonia absorption process in the absorber. The temperature difference of solution decreases with the increasing inlet coolant temperature. The heat transfer performance of a real type shell-and-tube absorber with the AAR system is a more sensitive function of the coolant inlet temperature than the solution inlet temperature, The ENCM developed in the present study can be used to estimate the actual thickness of a falling film along a horizontal tube in the shell-and-tube absorber of the AAR system, which is very diflicult to measure experimentally. The ammonia absorption rate decreases with inlet temperature cf a weak ammonia solution and inlet coolant temperature.",
keywords = "AAR system, Absorber, Ammonia absorption, Heat and mass transfer, Shell-and-tube",
author = "Lee, {Chan H.} and Kang, {Yong Tae} and Kang, {Hyun U.} and Kim, {Sung Hyun}",
year = "2005",
month = "11",
day = "9",
doi = "10.1252/jcej.38.520",
language = "English",
volume = "38",
pages = "520--527",
journal = "Journal of Chemical Engineering of Japan",
issn = "0021-9592",
publisher = "Society of Chemical Engineers, Japan",
number = "7",

}

TY - JOUR

T1 - Numerical and experimental study of falling film in ammonia absorption refrigeration systems

AU - Lee, Chan H.

AU - Kang, Yong Tae

AU - Kang, Hyun U.

AU - Kim, Sung Hyun

PY - 2005/11/9

Y1 - 2005/11/9

N2 - A shell-and-tube absorber and an ammonia absorption refrigeration (AAR) system were constructed to study falling film absorption on a horizontal tube. An empirical and numerical combined method (ENCM) was devloped to estimate the actual falling film thickness using parametric analysis with a simplified mathematical falling film model and experimental results. Numerical and experimental studies showed that the simplified mathematical falling film model has an exact physical response about ammonia absorption process in the absorber. The temperature difference of solution decreases with the increasing inlet coolant temperature. The heat transfer performance of a real type shell-and-tube absorber with the AAR system is a more sensitive function of the coolant inlet temperature than the solution inlet temperature, The ENCM developed in the present study can be used to estimate the actual thickness of a falling film along a horizontal tube in the shell-and-tube absorber of the AAR system, which is very diflicult to measure experimentally. The ammonia absorption rate decreases with inlet temperature cf a weak ammonia solution and inlet coolant temperature.

AB - A shell-and-tube absorber and an ammonia absorption refrigeration (AAR) system were constructed to study falling film absorption on a horizontal tube. An empirical and numerical combined method (ENCM) was devloped to estimate the actual falling film thickness using parametric analysis with a simplified mathematical falling film model and experimental results. Numerical and experimental studies showed that the simplified mathematical falling film model has an exact physical response about ammonia absorption process in the absorber. The temperature difference of solution decreases with the increasing inlet coolant temperature. The heat transfer performance of a real type shell-and-tube absorber with the AAR system is a more sensitive function of the coolant inlet temperature than the solution inlet temperature, The ENCM developed in the present study can be used to estimate the actual thickness of a falling film along a horizontal tube in the shell-and-tube absorber of the AAR system, which is very diflicult to measure experimentally. The ammonia absorption rate decreases with inlet temperature cf a weak ammonia solution and inlet coolant temperature.

KW - AAR system

KW - Absorber

KW - Ammonia absorption

KW - Heat and mass transfer

KW - Shell-and-tube

UR - http://www.scopus.com/inward/record.url?scp=27544438111&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=27544438111&partnerID=8YFLogxK

U2 - 10.1252/jcej.38.520

DO - 10.1252/jcej.38.520

M3 - Article

VL - 38

SP - 520

EP - 527

JO - Journal of Chemical Engineering of Japan

JF - Journal of Chemical Engineering of Japan

SN - 0021-9592