Numerical simulation for thermal response test performance in closed-loop vertical ground heat exchanger

Jong Min Choi, Chulho Lee, Moonseo Park, Shin Hyung Kang, Hangseok Choi

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

In this study, a series of numerical analyses was performed in order to evaluate the performance of full-scale closed-loop vertical ground heat exchangers constructed in Wonju, South Korea. The circulating HDPE pipe, borehole and surrounding ground formation were modeled using FLUENT, a finite-volume method (FVM) program, for analyzing the heat transfer process of the ground heat exchanger system. Two user-defined functions (UDFs) accounting for the difference in the temperature of the circulating inflow and outflow fluid and the variation of ground temperature with depth were adopted in the FLUENT modeling. The thermal conductivities of grouts (cement vs. bentonite) measured in laboratory were used as input values in the numerical analyses to compare the thermal efficiency of the cement and bentonite grouts used for installing the closed-loop vertical ground heat exchanger. A series of numerical analyses was carried out to simulate in-situ thermal response tests performed in the construction site. From the comparison between the in-situ thermal response test results and numerical simulations, the average thermal conductivity of the ground formation in the construction site is back-calculated as approximately 4 W/mK. This value can be used in evaluating the long-term performance of the closed-loop vertical ground heat exchanger.

Original languageEnglish
Pages (from-to)1668-1673
Number of pages6
JournalScience China Technological Sciences
Volume54
Issue number7
DOIs
Publication statusPublished - 2011 Jul 1

Fingerprint

Heat exchangers
Bentonite
Computer simulation
Thermal conductivity
Cements
Finite volume method
Polyethylene
High density polyethylenes
Boreholes
Pipe
Heat transfer
Temperature
Fluids
Hot Temperature

Keywords

  • bentonite grout
  • cement grout
  • closed-loop vertical ground heat exchanger
  • finite-volume method
  • in-situ thermal response test
  • thermal conductivity

ASJC Scopus subject areas

  • Engineering(all)
  • Materials Science(all)

Cite this

Numerical simulation for thermal response test performance in closed-loop vertical ground heat exchanger. / Choi, Jong Min; Lee, Chulho; Park, Moonseo; Kang, Shin Hyung; Choi, Hangseok.

In: Science China Technological Sciences, Vol. 54, No. 7, 01.07.2011, p. 1668-1673.

Research output: Contribution to journalArticle

Choi, Jong Min ; Lee, Chulho ; Park, Moonseo ; Kang, Shin Hyung ; Choi, Hangseok. / Numerical simulation for thermal response test performance in closed-loop vertical ground heat exchanger. In: Science China Technological Sciences. 2011 ; Vol. 54, No. 7. pp. 1668-1673.
@article{70d368d9bd0d498084f134011589900f,
title = "Numerical simulation for thermal response test performance in closed-loop vertical ground heat exchanger",
abstract = "In this study, a series of numerical analyses was performed in order to evaluate the performance of full-scale closed-loop vertical ground heat exchangers constructed in Wonju, South Korea. The circulating HDPE pipe, borehole and surrounding ground formation were modeled using FLUENT, a finite-volume method (FVM) program, for analyzing the heat transfer process of the ground heat exchanger system. Two user-defined functions (UDFs) accounting for the difference in the temperature of the circulating inflow and outflow fluid and the variation of ground temperature with depth were adopted in the FLUENT modeling. The thermal conductivities of grouts (cement vs. bentonite) measured in laboratory were used as input values in the numerical analyses to compare the thermal efficiency of the cement and bentonite grouts used for installing the closed-loop vertical ground heat exchanger. A series of numerical analyses was carried out to simulate in-situ thermal response tests performed in the construction site. From the comparison between the in-situ thermal response test results and numerical simulations, the average thermal conductivity of the ground formation in the construction site is back-calculated as approximately 4 W/mK. This value can be used in evaluating the long-term performance of the closed-loop vertical ground heat exchanger.",
keywords = "bentonite grout, cement grout, closed-loop vertical ground heat exchanger, finite-volume method, in-situ thermal response test, thermal conductivity",
author = "Choi, {Jong Min} and Chulho Lee and Moonseo Park and Kang, {Shin Hyung} and Hangseok Choi",
year = "2011",
month = "7",
day = "1",
doi = "10.1007/s11431-011-4389-x",
language = "English",
volume = "54",
pages = "1668--1673",
journal = "Science in China, Series E: Technological Sciences",
issn = "1006-9321",
publisher = "Science in China Press",
number = "7",

}

TY - JOUR

T1 - Numerical simulation for thermal response test performance in closed-loop vertical ground heat exchanger

AU - Choi, Jong Min

AU - Lee, Chulho

AU - Park, Moonseo

AU - Kang, Shin Hyung

AU - Choi, Hangseok

PY - 2011/7/1

Y1 - 2011/7/1

N2 - In this study, a series of numerical analyses was performed in order to evaluate the performance of full-scale closed-loop vertical ground heat exchangers constructed in Wonju, South Korea. The circulating HDPE pipe, borehole and surrounding ground formation were modeled using FLUENT, a finite-volume method (FVM) program, for analyzing the heat transfer process of the ground heat exchanger system. Two user-defined functions (UDFs) accounting for the difference in the temperature of the circulating inflow and outflow fluid and the variation of ground temperature with depth were adopted in the FLUENT modeling. The thermal conductivities of grouts (cement vs. bentonite) measured in laboratory were used as input values in the numerical analyses to compare the thermal efficiency of the cement and bentonite grouts used for installing the closed-loop vertical ground heat exchanger. A series of numerical analyses was carried out to simulate in-situ thermal response tests performed in the construction site. From the comparison between the in-situ thermal response test results and numerical simulations, the average thermal conductivity of the ground formation in the construction site is back-calculated as approximately 4 W/mK. This value can be used in evaluating the long-term performance of the closed-loop vertical ground heat exchanger.

AB - In this study, a series of numerical analyses was performed in order to evaluate the performance of full-scale closed-loop vertical ground heat exchangers constructed in Wonju, South Korea. The circulating HDPE pipe, borehole and surrounding ground formation were modeled using FLUENT, a finite-volume method (FVM) program, for analyzing the heat transfer process of the ground heat exchanger system. Two user-defined functions (UDFs) accounting for the difference in the temperature of the circulating inflow and outflow fluid and the variation of ground temperature with depth were adopted in the FLUENT modeling. The thermal conductivities of grouts (cement vs. bentonite) measured in laboratory were used as input values in the numerical analyses to compare the thermal efficiency of the cement and bentonite grouts used for installing the closed-loop vertical ground heat exchanger. A series of numerical analyses was carried out to simulate in-situ thermal response tests performed in the construction site. From the comparison between the in-situ thermal response test results and numerical simulations, the average thermal conductivity of the ground formation in the construction site is back-calculated as approximately 4 W/mK. This value can be used in evaluating the long-term performance of the closed-loop vertical ground heat exchanger.

KW - bentonite grout

KW - cement grout

KW - closed-loop vertical ground heat exchanger

KW - finite-volume method

KW - in-situ thermal response test

KW - thermal conductivity

UR - http://www.scopus.com/inward/record.url?scp=80051579082&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80051579082&partnerID=8YFLogxK

U2 - 10.1007/s11431-011-4389-x

DO - 10.1007/s11431-011-4389-x

M3 - Article

VL - 54

SP - 1668

EP - 1673

JO - Science in China, Series E: Technological Sciences

JF - Science in China, Series E: Technological Sciences

SN - 1006-9321

IS - 7

ER -