Numerical study of the effects of injection-port design on the heating performance of an R134a heat pump with vapor injection used in electric vehicles

Jongho Jung, Yongseok Jeon, Hoseong Lee, Yong Chan Kim

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

Heat pumps, which enable the cooling and heating of vehicular cabins, consume a significant portion of the total energy consumption in electric vehicles (EVs). The efficiency of the heat pump is typically degraded owing to cold-weather conditions, so the refrigerant-injection technique has been proposed for improving the system performance and compressor reliability. In this study, a simulation model for an R134a heat pump with vapor injection is developed and validated by performing thermodynamic analyses with geometrical information. The effects of the injection-port design are investigated using the developed numerical model. Single-injection and dual-injection ports are considered to optimize the coefficient of performance (COP) and isentropic efficiency by controlling the injection mass flow rate. The optimal angles of the single- and dual-injection ports are determined to be 440° and 535°/355° (for pocket A/B), respectively, while the corresponding COPs are improved by 7.5% and 9.8%, respectively, compared to the non-injection heat pump at an outdoor temperature of −10 °C.

Original languageEnglish
Pages (from-to)800-811
Number of pages12
JournalApplied Thermal Engineering
Volume127
DOIs
Publication statusPublished - 2017 Dec 25

Fingerprint

Electric vehicles
Vapors
Pumps
Heating
Refrigerants
Compressors
Numerical models
Energy utilization
Flow rate
Thermodynamics
Cooling
Hot Temperature
Temperature

Keywords

  • Dual injection
  • Electric vehicle
  • Heat pump
  • Injection port
  • Vapor injection

ASJC Scopus subject areas

  • Energy Engineering and Power Technology
  • Industrial and Manufacturing Engineering

Cite this

Numerical study of the effects of injection-port design on the heating performance of an R134a heat pump with vapor injection used in electric vehicles. / Jung, Jongho; Jeon, Yongseok; Lee, Hoseong; Kim, Yong Chan.

In: Applied Thermal Engineering, Vol. 127, 25.12.2017, p. 800-811.

Research output: Contribution to journalArticle

@article{32165032dc604862b1832215fefc6fb4,
title = "Numerical study of the effects of injection-port design on the heating performance of an R134a heat pump with vapor injection used in electric vehicles",
abstract = "Heat pumps, which enable the cooling and heating of vehicular cabins, consume a significant portion of the total energy consumption in electric vehicles (EVs). The efficiency of the heat pump is typically degraded owing to cold-weather conditions, so the refrigerant-injection technique has been proposed for improving the system performance and compressor reliability. In this study, a simulation model for an R134a heat pump with vapor injection is developed and validated by performing thermodynamic analyses with geometrical information. The effects of the injection-port design are investigated using the developed numerical model. Single-injection and dual-injection ports are considered to optimize the coefficient of performance (COP) and isentropic efficiency by controlling the injection mass flow rate. The optimal angles of the single- and dual-injection ports are determined to be 440° and 535°/355° (for pocket A/B), respectively, while the corresponding COPs are improved by 7.5{\%} and 9.8{\%}, respectively, compared to the non-injection heat pump at an outdoor temperature of −10 °C.",
keywords = "Dual injection, Electric vehicle, Heat pump, Injection port, Vapor injection",
author = "Jongho Jung and Yongseok Jeon and Hoseong Lee and Kim, {Yong Chan}",
year = "2017",
month = "12",
day = "25",
doi = "10.1016/j.applthermaleng.2017.08.098",
language = "English",
volume = "127",
pages = "800--811",
journal = "Applied Thermal Engineering",
issn = "1359-4311",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - Numerical study of the effects of injection-port design on the heating performance of an R134a heat pump with vapor injection used in electric vehicles

AU - Jung, Jongho

AU - Jeon, Yongseok

AU - Lee, Hoseong

AU - Kim, Yong Chan

PY - 2017/12/25

Y1 - 2017/12/25

N2 - Heat pumps, which enable the cooling and heating of vehicular cabins, consume a significant portion of the total energy consumption in electric vehicles (EVs). The efficiency of the heat pump is typically degraded owing to cold-weather conditions, so the refrigerant-injection technique has been proposed for improving the system performance and compressor reliability. In this study, a simulation model for an R134a heat pump with vapor injection is developed and validated by performing thermodynamic analyses with geometrical information. The effects of the injection-port design are investigated using the developed numerical model. Single-injection and dual-injection ports are considered to optimize the coefficient of performance (COP) and isentropic efficiency by controlling the injection mass flow rate. The optimal angles of the single- and dual-injection ports are determined to be 440° and 535°/355° (for pocket A/B), respectively, while the corresponding COPs are improved by 7.5% and 9.8%, respectively, compared to the non-injection heat pump at an outdoor temperature of −10 °C.

AB - Heat pumps, which enable the cooling and heating of vehicular cabins, consume a significant portion of the total energy consumption in electric vehicles (EVs). The efficiency of the heat pump is typically degraded owing to cold-weather conditions, so the refrigerant-injection technique has been proposed for improving the system performance and compressor reliability. In this study, a simulation model for an R134a heat pump with vapor injection is developed and validated by performing thermodynamic analyses with geometrical information. The effects of the injection-port design are investigated using the developed numerical model. Single-injection and dual-injection ports are considered to optimize the coefficient of performance (COP) and isentropic efficiency by controlling the injection mass flow rate. The optimal angles of the single- and dual-injection ports are determined to be 440° and 535°/355° (for pocket A/B), respectively, while the corresponding COPs are improved by 7.5% and 9.8%, respectively, compared to the non-injection heat pump at an outdoor temperature of −10 °C.

KW - Dual injection

KW - Electric vehicle

KW - Heat pump

KW - Injection port

KW - Vapor injection

UR - http://www.scopus.com/inward/record.url?scp=85027842209&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85027842209&partnerID=8YFLogxK

U2 - 10.1016/j.applthermaleng.2017.08.098

DO - 10.1016/j.applthermaleng.2017.08.098

M3 - Article

AN - SCOPUS:85027842209

VL - 127

SP - 800

EP - 811

JO - Applied Thermal Engineering

JF - Applied Thermal Engineering

SN - 1359-4311

ER -