Optimized T1-weighted contrast for single-slab 3D turbo spin-echo imaging with long echo trains

Application to whole-brain imaging

Jaeseok Park, John P. Mugler, Wilhelm Horger, Berthold Kiefer

Research output: Contribution to journalArticle

48 Citations (Scopus)

Abstract

T1-weighted contrast is conventionally obtained using multislice two-dimensional (2D) spin-echo (SE) imaging. Achieving isotropic, high spatial resolution is problematic with conventional methods due to a long acquisition time, imperfect slice profiles, or high-energy deposition. Single-slab 3D SE imaging was recently developed employing long echo trains with variable low flip angles to address these problems. However, long echo trains may yield suboptimal T1-weighted contrast, since T2 weighting of the signals tends to develop along the echo train. Image blurring may also occur if high spatial frequency signals are acquired with low signal intensity. The purpose of this work was to develop an optimized T1-weighted version of single-slab 3D SE imaging with long echo trains. Refocusing flip angles were calculated based on a tissue-specific prescribed signal evolution. Spatially nonselective excitation was used, followed by half-Fourier acquisition in the in-plane phase encoding (PE) direction. Restore radio frequency (RF) pulses were applied at the end of the echo train to optimize T1-weighted contrast. Imaging parameters were optimized by using Bloch equation simulation, and imaging studies of healthy subjects were performed to investigate the feasibility of whole-brain imaging with isotropic, high spatial resolution. The proposed technique permitted highly-efficient T1-weighted 3D SE imaging of the brain.

Original languageEnglish
Pages (from-to)982-992
Number of pages11
JournalMagnetic Resonance in Medicine
Volume58
Issue number5
DOIs
Publication statusPublished - 2007 Nov 1
Externally publishedYes

Fingerprint

Neuroimaging
Magnetic Resonance Imaging
Radio
Healthy Volunteers
Brain

Keywords

  • Magnetic resonance imaging (MRI)
  • Rapid imaging
  • Spin echo
  • T1 contrast
  • Three-dimensional
  • Variable flip angle

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Optimized T1-weighted contrast for single-slab 3D turbo spin-echo imaging with long echo trains : Application to whole-brain imaging. / Park, Jaeseok; Mugler, John P.; Horger, Wilhelm; Kiefer, Berthold.

In: Magnetic Resonance in Medicine, Vol. 58, No. 5, 01.11.2007, p. 982-992.

Research output: Contribution to journalArticle

@article{ab8ae7bb11a4425abd86fdc49f520b85,
title = "Optimized T1-weighted contrast for single-slab 3D turbo spin-echo imaging with long echo trains: Application to whole-brain imaging",
abstract = "T1-weighted contrast is conventionally obtained using multislice two-dimensional (2D) spin-echo (SE) imaging. Achieving isotropic, high spatial resolution is problematic with conventional methods due to a long acquisition time, imperfect slice profiles, or high-energy deposition. Single-slab 3D SE imaging was recently developed employing long echo trains with variable low flip angles to address these problems. However, long echo trains may yield suboptimal T1-weighted contrast, since T2 weighting of the signals tends to develop along the echo train. Image blurring may also occur if high spatial frequency signals are acquired with low signal intensity. The purpose of this work was to develop an optimized T1-weighted version of single-slab 3D SE imaging with long echo trains. Refocusing flip angles were calculated based on a tissue-specific prescribed signal evolution. Spatially nonselective excitation was used, followed by half-Fourier acquisition in the in-plane phase encoding (PE) direction. Restore radio frequency (RF) pulses were applied at the end of the echo train to optimize T1-weighted contrast. Imaging parameters were optimized by using Bloch equation simulation, and imaging studies of healthy subjects were performed to investigate the feasibility of whole-brain imaging with isotropic, high spatial resolution. The proposed technique permitted highly-efficient T1-weighted 3D SE imaging of the brain.",
keywords = "Magnetic resonance imaging (MRI), Rapid imaging, Spin echo, T1 contrast, Three-dimensional, Variable flip angle",
author = "Jaeseok Park and Mugler, {John P.} and Wilhelm Horger and Berthold Kiefer",
year = "2007",
month = "11",
day = "1",
doi = "10.1002/mrm.21386",
language = "English",
volume = "58",
pages = "982--992",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "5",

}

TY - JOUR

T1 - Optimized T1-weighted contrast for single-slab 3D turbo spin-echo imaging with long echo trains

T2 - Application to whole-brain imaging

AU - Park, Jaeseok

AU - Mugler, John P.

AU - Horger, Wilhelm

AU - Kiefer, Berthold

PY - 2007/11/1

Y1 - 2007/11/1

N2 - T1-weighted contrast is conventionally obtained using multislice two-dimensional (2D) spin-echo (SE) imaging. Achieving isotropic, high spatial resolution is problematic with conventional methods due to a long acquisition time, imperfect slice profiles, or high-energy deposition. Single-slab 3D SE imaging was recently developed employing long echo trains with variable low flip angles to address these problems. However, long echo trains may yield suboptimal T1-weighted contrast, since T2 weighting of the signals tends to develop along the echo train. Image blurring may also occur if high spatial frequency signals are acquired with low signal intensity. The purpose of this work was to develop an optimized T1-weighted version of single-slab 3D SE imaging with long echo trains. Refocusing flip angles were calculated based on a tissue-specific prescribed signal evolution. Spatially nonselective excitation was used, followed by half-Fourier acquisition in the in-plane phase encoding (PE) direction. Restore radio frequency (RF) pulses were applied at the end of the echo train to optimize T1-weighted contrast. Imaging parameters were optimized by using Bloch equation simulation, and imaging studies of healthy subjects were performed to investigate the feasibility of whole-brain imaging with isotropic, high spatial resolution. The proposed technique permitted highly-efficient T1-weighted 3D SE imaging of the brain.

AB - T1-weighted contrast is conventionally obtained using multislice two-dimensional (2D) spin-echo (SE) imaging. Achieving isotropic, high spatial resolution is problematic with conventional methods due to a long acquisition time, imperfect slice profiles, or high-energy deposition. Single-slab 3D SE imaging was recently developed employing long echo trains with variable low flip angles to address these problems. However, long echo trains may yield suboptimal T1-weighted contrast, since T2 weighting of the signals tends to develop along the echo train. Image blurring may also occur if high spatial frequency signals are acquired with low signal intensity. The purpose of this work was to develop an optimized T1-weighted version of single-slab 3D SE imaging with long echo trains. Refocusing flip angles were calculated based on a tissue-specific prescribed signal evolution. Spatially nonselective excitation was used, followed by half-Fourier acquisition in the in-plane phase encoding (PE) direction. Restore radio frequency (RF) pulses were applied at the end of the echo train to optimize T1-weighted contrast. Imaging parameters were optimized by using Bloch equation simulation, and imaging studies of healthy subjects were performed to investigate the feasibility of whole-brain imaging with isotropic, high spatial resolution. The proposed technique permitted highly-efficient T1-weighted 3D SE imaging of the brain.

KW - Magnetic resonance imaging (MRI)

KW - Rapid imaging

KW - Spin echo

KW - T1 contrast

KW - Three-dimensional

KW - Variable flip angle

UR - http://www.scopus.com/inward/record.url?scp=35948964075&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=35948964075&partnerID=8YFLogxK

U2 - 10.1002/mrm.21386

DO - 10.1002/mrm.21386

M3 - Article

VL - 58

SP - 982

EP - 992

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 5

ER -