Abstract

Measurement of red blood cell (RBC) deformability by ektacytometry yields a set of elongation indexes (EI) measured at various shear stresses (SS) presented as SS-EI curves, or tabulated data. These are useful for detailed analysis, but may not be appropriate when a simple comparison of a global parameter between groups is required. Based on the characteristic shape of SS-EI curves, two approaches have been proposed to calculate the maximal RBC elongation index (EImax) and the shear stress required for one-half of this maximal deformation (SS1/2): (i) linear Lineweaver-Burke (LB) model; (ii) Streekstra-Bronkhorst (SB) model. Both approaches have specific assumptions and thus may be subject to the measurement conditions. Using RBC treated with various concentrations of glutaraldehyde (GA) and data obtained by ektacytometry, the two approaches have been compared for nine different ranges of SS between 0.675 Pa. Our results indicate that: (i) the sensitivity of both models can be affected by the SS range and limits employed; (ii) over the entire range of SS-data, a non-linear curve fitting approach to the LB model gave more consistent results than a linear approach; (iii) the LB method is better for detecting SS1/2 differences between RBC treated with 0.0010.005% glutaraldehyde (GA) and for a 40% mixture of rigid cells but is equally sensitive to SB for 10% rigid cells; and (iv) the LB and SB methods for EI max are equivalent for 0.001% and 0.003% GA and 40% rigid, with the SB better for 0.005% GA and the LB better for 10% rigid.

Original languageEnglish
Pages (from-to)777-788
Number of pages12
JournalScandinavian Journal of Clinical and Laboratory Investigation
Volume69
Issue number7
DOIs
Publication statusPublished - 2009 Dec 1

Fingerprint

Glutaral
Parameterization
Shear stress
Elongation
Blood
Erythrocytes
Cells
Curve fitting
Formability

Keywords

  • Ektacytometry
  • Erythrocyte deformability
  • Glutaraldehyde
  • Hemorheology
  • Lineweaver-Burke

ASJC Scopus subject areas

  • Clinical Biochemistry

Cite this

Parameterization of red blood cell elongation index - Shear stress curves obtained by ektacytometry. / Baskurt, Oguz K.; Hardeman, Max R.; Uyuklu, Mehmet; Ulker, Pinar; Cengiz, Melike; Nemeth, Norbert; Shin, Sehyun; Alexy, Tamas; Meiselman, Herbert J.

In: Scandinavian Journal of Clinical and Laboratory Investigation, Vol. 69, No. 7, 01.12.2009, p. 777-788.

Research output: Contribution to journalArticle

Baskurt, Oguz K. ; Hardeman, Max R. ; Uyuklu, Mehmet ; Ulker, Pinar ; Cengiz, Melike ; Nemeth, Norbert ; Shin, Sehyun ; Alexy, Tamas ; Meiselman, Herbert J. / Parameterization of red blood cell elongation index - Shear stress curves obtained by ektacytometry. In: Scandinavian Journal of Clinical and Laboratory Investigation. 2009 ; Vol. 69, No. 7. pp. 777-788.
@article{bb728b80d15d47f2b849e66dd05d0612,
title = "Parameterization of red blood cell elongation index - Shear stress curves obtained by ektacytometry",
abstract = "Measurement of red blood cell (RBC) deformability by ektacytometry yields a set of elongation indexes (EI) measured at various shear stresses (SS) presented as SS-EI curves, or tabulated data. These are useful for detailed analysis, but may not be appropriate when a simple comparison of a global parameter between groups is required. Based on the characteristic shape of SS-EI curves, two approaches have been proposed to calculate the maximal RBC elongation index (EImax) and the shear stress required for one-half of this maximal deformation (SS1/2): (i) linear Lineweaver-Burke (LB) model; (ii) Streekstra-Bronkhorst (SB) model. Both approaches have specific assumptions and thus may be subject to the measurement conditions. Using RBC treated with various concentrations of glutaraldehyde (GA) and data obtained by ektacytometry, the two approaches have been compared for nine different ranges of SS between 0.675 Pa. Our results indicate that: (i) the sensitivity of both models can be affected by the SS range and limits employed; (ii) over the entire range of SS-data, a non-linear curve fitting approach to the LB model gave more consistent results than a linear approach; (iii) the LB method is better for detecting SS1/2 differences between RBC treated with 0.0010.005{\%} glutaraldehyde (GA) and for a 40{\%} mixture of rigid cells but is equally sensitive to SB for 10{\%} rigid cells; and (iv) the LB and SB methods for EI max are equivalent for 0.001{\%} and 0.003{\%} GA and 40{\%} rigid, with the SB better for 0.005{\%} GA and the LB better for 10{\%} rigid.",
keywords = "Ektacytometry, Erythrocyte deformability, Glutaraldehyde, Hemorheology, Lineweaver-Burke",
author = "Baskurt, {Oguz K.} and Hardeman, {Max R.} and Mehmet Uyuklu and Pinar Ulker and Melike Cengiz and Norbert Nemeth and Sehyun Shin and Tamas Alexy and Meiselman, {Herbert J.}",
year = "2009",
month = "12",
day = "1",
doi = "10.3109/00365510903266069",
language = "English",
volume = "69",
pages = "777--788",
journal = "Scandinavian Journal of Clinical and Laboratory Investigation",
issn = "0036-5513",
publisher = "Informa Healthcare",
number = "7",

}

TY - JOUR

T1 - Parameterization of red blood cell elongation index - Shear stress curves obtained by ektacytometry

AU - Baskurt, Oguz K.

AU - Hardeman, Max R.

AU - Uyuklu, Mehmet

AU - Ulker, Pinar

AU - Cengiz, Melike

AU - Nemeth, Norbert

AU - Shin, Sehyun

AU - Alexy, Tamas

AU - Meiselman, Herbert J.

PY - 2009/12/1

Y1 - 2009/12/1

N2 - Measurement of red blood cell (RBC) deformability by ektacytometry yields a set of elongation indexes (EI) measured at various shear stresses (SS) presented as SS-EI curves, or tabulated data. These are useful for detailed analysis, but may not be appropriate when a simple comparison of a global parameter between groups is required. Based on the characteristic shape of SS-EI curves, two approaches have been proposed to calculate the maximal RBC elongation index (EImax) and the shear stress required for one-half of this maximal deformation (SS1/2): (i) linear Lineweaver-Burke (LB) model; (ii) Streekstra-Bronkhorst (SB) model. Both approaches have specific assumptions and thus may be subject to the measurement conditions. Using RBC treated with various concentrations of glutaraldehyde (GA) and data obtained by ektacytometry, the two approaches have been compared for nine different ranges of SS between 0.675 Pa. Our results indicate that: (i) the sensitivity of both models can be affected by the SS range and limits employed; (ii) over the entire range of SS-data, a non-linear curve fitting approach to the LB model gave more consistent results than a linear approach; (iii) the LB method is better for detecting SS1/2 differences between RBC treated with 0.0010.005% glutaraldehyde (GA) and for a 40% mixture of rigid cells but is equally sensitive to SB for 10% rigid cells; and (iv) the LB and SB methods for EI max are equivalent for 0.001% and 0.003% GA and 40% rigid, with the SB better for 0.005% GA and the LB better for 10% rigid.

AB - Measurement of red blood cell (RBC) deformability by ektacytometry yields a set of elongation indexes (EI) measured at various shear stresses (SS) presented as SS-EI curves, or tabulated data. These are useful for detailed analysis, but may not be appropriate when a simple comparison of a global parameter between groups is required. Based on the characteristic shape of SS-EI curves, two approaches have been proposed to calculate the maximal RBC elongation index (EImax) and the shear stress required for one-half of this maximal deformation (SS1/2): (i) linear Lineweaver-Burke (LB) model; (ii) Streekstra-Bronkhorst (SB) model. Both approaches have specific assumptions and thus may be subject to the measurement conditions. Using RBC treated with various concentrations of glutaraldehyde (GA) and data obtained by ektacytometry, the two approaches have been compared for nine different ranges of SS between 0.675 Pa. Our results indicate that: (i) the sensitivity of both models can be affected by the SS range and limits employed; (ii) over the entire range of SS-data, a non-linear curve fitting approach to the LB model gave more consistent results than a linear approach; (iii) the LB method is better for detecting SS1/2 differences between RBC treated with 0.0010.005% glutaraldehyde (GA) and for a 40% mixture of rigid cells but is equally sensitive to SB for 10% rigid cells; and (iv) the LB and SB methods for EI max are equivalent for 0.001% and 0.003% GA and 40% rigid, with the SB better for 0.005% GA and the LB better for 10% rigid.

KW - Ektacytometry

KW - Erythrocyte deformability

KW - Glutaraldehyde

KW - Hemorheology

KW - Lineweaver-Burke

UR - http://www.scopus.com/inward/record.url?scp=74549224444&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=74549224444&partnerID=8YFLogxK

U2 - 10.3109/00365510903266069

DO - 10.3109/00365510903266069

M3 - Article

C2 - 19929721

AN - SCOPUS:74549224444

VL - 69

SP - 777

EP - 788

JO - Scandinavian Journal of Clinical and Laboratory Investigation

JF - Scandinavian Journal of Clinical and Laboratory Investigation

SN - 0036-5513

IS - 7

ER -