Performance Criterion of Phasor Measurement Units for Distribution System State Estimation

Jonghoek Kim, Hyun Tae Kim, Sungyun Choi

Research output: Contribution to journalArticle

Abstract

A phasor measurement unit (PMU) is a device that can directly measure the phase angles of voltages and currents, with high accuracy, using accurate time signals. Hence, PMUs have originally been used to improve the accuracy of transmission system state estimation. The merit of PMUs, further, extends the scope of its application to distribution system state estimation (DSSE), which has recently been studied because of the growing needs for distribution system management due to high levels of distributed energy resources. More importantly, the scarcity of measuring sensors in distribution systems highlights the role of PMUs for the DSSE. However, the full deployment of PMUs in distribution systems is practically impossible because of the high installation costs and geographically large size of these systems. Therefore, this paper investigates the adequate and economic performance of PMUs to meet the DSSE requirement with respect to the estimation accuracy. The accuracy of different PMU performance classes and the accuracy of various measurement types are first defined. Different sets of measurements are then assigned to different meter locations in a testbed that is a three-phase unbalanced, asymmetric system. Various performance metrics for each case study are computed and compared from the numerical simulation results.

Original languageEnglish
Article number8786098
Pages (from-to)106372-106384
Number of pages13
JournalIEEE Access
Volume7
DOIs
Publication statusPublished - 2019 Jan 1

Fingerprint

Phasor measurement units
State estimation
Energy resources
Testbeds
Economics
Sensors
Computer simulation
Electric potential
Costs

Keywords

  • Distribution system state estimation
  • phasor measurement unit
  • power system state estimation

ASJC Scopus subject areas

  • Computer Science(all)
  • Materials Science(all)
  • Engineering(all)

Cite this

Performance Criterion of Phasor Measurement Units for Distribution System State Estimation. / Kim, Jonghoek; Kim, Hyun Tae; Choi, Sungyun.

In: IEEE Access, Vol. 7, 8786098, 01.01.2019, p. 106372-106384.

Research output: Contribution to journalArticle

@article{667e8fb918bd4028ae3de28b176009a6,
title = "Performance Criterion of Phasor Measurement Units for Distribution System State Estimation",
abstract = "A phasor measurement unit (PMU) is a device that can directly measure the phase angles of voltages and currents, with high accuracy, using accurate time signals. Hence, PMUs have originally been used to improve the accuracy of transmission system state estimation. The merit of PMUs, further, extends the scope of its application to distribution system state estimation (DSSE), which has recently been studied because of the growing needs for distribution system management due to high levels of distributed energy resources. More importantly, the scarcity of measuring sensors in distribution systems highlights the role of PMUs for the DSSE. However, the full deployment of PMUs in distribution systems is practically impossible because of the high installation costs and geographically large size of these systems. Therefore, this paper investigates the adequate and economic performance of PMUs to meet the DSSE requirement with respect to the estimation accuracy. The accuracy of different PMU performance classes and the accuracy of various measurement types are first defined. Different sets of measurements are then assigned to different meter locations in a testbed that is a three-phase unbalanced, asymmetric system. Various performance metrics for each case study are computed and compared from the numerical simulation results.",
keywords = "Distribution system state estimation, phasor measurement unit, power system state estimation",
author = "Jonghoek Kim and Kim, {Hyun Tae} and Sungyun Choi",
year = "2019",
month = "1",
day = "1",
doi = "10.1109/ACCESS.2019.2932940",
language = "English",
volume = "7",
pages = "106372--106384",
journal = "IEEE Access",
issn = "2169-3536",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - JOUR

T1 - Performance Criterion of Phasor Measurement Units for Distribution System State Estimation

AU - Kim, Jonghoek

AU - Kim, Hyun Tae

AU - Choi, Sungyun

PY - 2019/1/1

Y1 - 2019/1/1

N2 - A phasor measurement unit (PMU) is a device that can directly measure the phase angles of voltages and currents, with high accuracy, using accurate time signals. Hence, PMUs have originally been used to improve the accuracy of transmission system state estimation. The merit of PMUs, further, extends the scope of its application to distribution system state estimation (DSSE), which has recently been studied because of the growing needs for distribution system management due to high levels of distributed energy resources. More importantly, the scarcity of measuring sensors in distribution systems highlights the role of PMUs for the DSSE. However, the full deployment of PMUs in distribution systems is practically impossible because of the high installation costs and geographically large size of these systems. Therefore, this paper investigates the adequate and economic performance of PMUs to meet the DSSE requirement with respect to the estimation accuracy. The accuracy of different PMU performance classes and the accuracy of various measurement types are first defined. Different sets of measurements are then assigned to different meter locations in a testbed that is a three-phase unbalanced, asymmetric system. Various performance metrics for each case study are computed and compared from the numerical simulation results.

AB - A phasor measurement unit (PMU) is a device that can directly measure the phase angles of voltages and currents, with high accuracy, using accurate time signals. Hence, PMUs have originally been used to improve the accuracy of transmission system state estimation. The merit of PMUs, further, extends the scope of its application to distribution system state estimation (DSSE), which has recently been studied because of the growing needs for distribution system management due to high levels of distributed energy resources. More importantly, the scarcity of measuring sensors in distribution systems highlights the role of PMUs for the DSSE. However, the full deployment of PMUs in distribution systems is practically impossible because of the high installation costs and geographically large size of these systems. Therefore, this paper investigates the adequate and economic performance of PMUs to meet the DSSE requirement with respect to the estimation accuracy. The accuracy of different PMU performance classes and the accuracy of various measurement types are first defined. Different sets of measurements are then assigned to different meter locations in a testbed that is a three-phase unbalanced, asymmetric system. Various performance metrics for each case study are computed and compared from the numerical simulation results.

KW - Distribution system state estimation

KW - phasor measurement unit

KW - power system state estimation

UR - http://www.scopus.com/inward/record.url?scp=85071123500&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85071123500&partnerID=8YFLogxK

U2 - 10.1109/ACCESS.2019.2932940

DO - 10.1109/ACCESS.2019.2932940

M3 - Article

VL - 7

SP - 106372

EP - 106384

JO - IEEE Access

JF - IEEE Access

SN - 2169-3536

M1 - 8786098

ER -