Performance degradation and recovery effect of direct formic acid fuel cells using a palladium anode catalyst

Seungmin Baek, Yongchai Kwon, Jonghee Han, Jinsoo Kim

Research output: Contribution to journalConference article

Abstract

Direct formic acid fuel cells (DFAFCs) using palladium (Pd) as an anode catalyst exhibit high performance. However, with use of the Pd, the performance of DFAFC is rapidly reduced while operation. To evaluate correlation between the undesirable effects of Pd such as deactivation and agglomerization and DFAFC performance, and to find out the best recovery condition of cell performance, 4-step electrochemical tests are consecutively implemented under the fixed cell voltages ranged from 0.2 V to 0.8 V; initial polarization, intentional degradation (current vs. time curve with fixed cell voltage), cyclic voltage scan-based reactivation, and polarization. According to these test results, performance degradation of DFAFC was almost similar after the intentional degradation test. However, after the reactivation test, performance of DFAFC degraded at 0.4 V was well-recovered, while those degraded at higher than 0.6 V were not sufficiently recovered. To characterize the effect of Pd on DFAFC performance, characterizations such as zeta potential, TEM, electrochemical impedance spectroscopy (EIS) and cyclic voltammogram (CV) were carried out. Based on the results, it was found that under 0.4 V, Pd particles were well distributed and its charge transfer resistance (Rct) was low, while Pd particles were agglomerated and Rct increased at higher than 0.6 V. Eventually, it is concluded that disparities in Pd particle distribution and Pd poisoning affect performance degradation and recovery of DFAFC.

Original languageEnglish
JournalACS National Meeting Book of Abstracts
Publication statusPublished - 2010 Dec 1
Externally publishedYes
Event240th ACS National Meeting and Exposition - Boston, MA, United States
Duration: 2010 Aug 222010 Aug 26

Fingerprint

Formic acid fuel cells (FAFC)
Palladium
Anodes
Recovery
Degradation
Catalysts
Electric potential
Polarization
Zeta potential
Electrochemical impedance spectroscopy
Charge transfer
Transmission electron microscopy

ASJC Scopus subject areas

  • Chemistry(all)
  • Chemical Engineering(all)

Cite this

Performance degradation and recovery effect of direct formic acid fuel cells using a palladium anode catalyst. / Baek, Seungmin; Kwon, Yongchai; Han, Jonghee; Kim, Jinsoo.

In: ACS National Meeting Book of Abstracts, 01.12.2010.

Research output: Contribution to journalConference article

@article{1b437e88565a4c0ab0de34f14fe25adf,
title = "Performance degradation and recovery effect of direct formic acid fuel cells using a palladium anode catalyst",
abstract = "Direct formic acid fuel cells (DFAFCs) using palladium (Pd) as an anode catalyst exhibit high performance. However, with use of the Pd, the performance of DFAFC is rapidly reduced while operation. To evaluate correlation between the undesirable effects of Pd such as deactivation and agglomerization and DFAFC performance, and to find out the best recovery condition of cell performance, 4-step electrochemical tests are consecutively implemented under the fixed cell voltages ranged from 0.2 V to 0.8 V; initial polarization, intentional degradation (current vs. time curve with fixed cell voltage), cyclic voltage scan-based reactivation, and polarization. According to these test results, performance degradation of DFAFC was almost similar after the intentional degradation test. However, after the reactivation test, performance of DFAFC degraded at 0.4 V was well-recovered, while those degraded at higher than 0.6 V were not sufficiently recovered. To characterize the effect of Pd on DFAFC performance, characterizations such as zeta potential, TEM, electrochemical impedance spectroscopy (EIS) and cyclic voltammogram (CV) were carried out. Based on the results, it was found that under 0.4 V, Pd particles were well distributed and its charge transfer resistance (Rct) was low, while Pd particles were agglomerated and Rct increased at higher than 0.6 V. Eventually, it is concluded that disparities in Pd particle distribution and Pd poisoning affect performance degradation and recovery of DFAFC.",
author = "Seungmin Baek and Yongchai Kwon and Jonghee Han and Jinsoo Kim",
year = "2010",
month = "12",
day = "1",
language = "English",
journal = "ACS National Meeting Book of Abstracts",
issn = "0065-7727",
publisher = "American Chemical Society",

}

TY - JOUR

T1 - Performance degradation and recovery effect of direct formic acid fuel cells using a palladium anode catalyst

AU - Baek, Seungmin

AU - Kwon, Yongchai

AU - Han, Jonghee

AU - Kim, Jinsoo

PY - 2010/12/1

Y1 - 2010/12/1

N2 - Direct formic acid fuel cells (DFAFCs) using palladium (Pd) as an anode catalyst exhibit high performance. However, with use of the Pd, the performance of DFAFC is rapidly reduced while operation. To evaluate correlation between the undesirable effects of Pd such as deactivation and agglomerization and DFAFC performance, and to find out the best recovery condition of cell performance, 4-step electrochemical tests are consecutively implemented under the fixed cell voltages ranged from 0.2 V to 0.8 V; initial polarization, intentional degradation (current vs. time curve with fixed cell voltage), cyclic voltage scan-based reactivation, and polarization. According to these test results, performance degradation of DFAFC was almost similar after the intentional degradation test. However, after the reactivation test, performance of DFAFC degraded at 0.4 V was well-recovered, while those degraded at higher than 0.6 V were not sufficiently recovered. To characterize the effect of Pd on DFAFC performance, characterizations such as zeta potential, TEM, electrochemical impedance spectroscopy (EIS) and cyclic voltammogram (CV) were carried out. Based on the results, it was found that under 0.4 V, Pd particles were well distributed and its charge transfer resistance (Rct) was low, while Pd particles were agglomerated and Rct increased at higher than 0.6 V. Eventually, it is concluded that disparities in Pd particle distribution and Pd poisoning affect performance degradation and recovery of DFAFC.

AB - Direct formic acid fuel cells (DFAFCs) using palladium (Pd) as an anode catalyst exhibit high performance. However, with use of the Pd, the performance of DFAFC is rapidly reduced while operation. To evaluate correlation between the undesirable effects of Pd such as deactivation and agglomerization and DFAFC performance, and to find out the best recovery condition of cell performance, 4-step electrochemical tests are consecutively implemented under the fixed cell voltages ranged from 0.2 V to 0.8 V; initial polarization, intentional degradation (current vs. time curve with fixed cell voltage), cyclic voltage scan-based reactivation, and polarization. According to these test results, performance degradation of DFAFC was almost similar after the intentional degradation test. However, after the reactivation test, performance of DFAFC degraded at 0.4 V was well-recovered, while those degraded at higher than 0.6 V were not sufficiently recovered. To characterize the effect of Pd on DFAFC performance, characterizations such as zeta potential, TEM, electrochemical impedance spectroscopy (EIS) and cyclic voltammogram (CV) were carried out. Based on the results, it was found that under 0.4 V, Pd particles were well distributed and its charge transfer resistance (Rct) was low, while Pd particles were agglomerated and Rct increased at higher than 0.6 V. Eventually, it is concluded that disparities in Pd particle distribution and Pd poisoning affect performance degradation and recovery of DFAFC.

UR - http://www.scopus.com/inward/record.url?scp=79951495491&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79951495491&partnerID=8YFLogxK

M3 - Conference article

AN - SCOPUS:79951495491

JO - ACS National Meeting Book of Abstracts

JF - ACS National Meeting Book of Abstracts

SN - 0065-7727

ER -