Performance enhancement of real-time detection of protozoan parasite, Cryptosporidium oocyst by a modified surface plasmon resonance (SPR) biosensor

Chang Duk Kang, Sang Wook Lee, Tai Hyun Park, Sang Jun Sim

Research output: Contribution to journalArticle

31 Citations (Scopus)

Abstract

Surface plasmon resonance (SPR) biosensor based on mixed self-assembled monolayers (SAMs) was developed for real-time detection of Cryptosporidium oocyst. The flow type SPR biosensor consisting of subsequent binding of antibody and oocyst in flowing buffer system was able to detect Cryptosporidium parvum oocyst in real-time with a detection limit of 1 × 106 oocyst/ml. To enhance the sensitivity of real-time detection, the modified flow type SPR biosensor was developed, which consisted of the immunoreaction step between the biotin-antibody and oocysts followed by the binding step of antibody bound oocysts onto the sensor surface. Not only was the immunoreaction yield with batch immune reaction improved, but the accessibility of analytes to the sensor surface was also enhanced since the binding event for SPR signal generation was exchanged to biotin-streptavidin binding with high affinity. Consequently, the real-time detection limit of 1 × 102 oocyst/ml was obtained in the modified flow type biosensor.

Original languageEnglish
Pages (from-to)387-390
Number of pages4
JournalEnzyme and Microbial Technology
Volume39
Issue number3
DOIs
Publication statusPublished - 2006 Jul 3
Externally publishedYes

Fingerprint

Cryptosporidium
Oocysts
Surface Plasmon Resonance
Surface plasmon resonance
Biosensing Techniques
Biosensors
Parasites
Biotin
Antibodies
Antigen-antibody reactions
Streptavidin
Sensors
Self assembled monolayers
Limit of Detection
Buffers
Cryptosporidium parvum

Keywords

  • Biosensor
  • Cryptosporidium oocyst
  • Real-time detection
  • Surface plasmon resonance

ASJC Scopus subject areas

  • Biochemistry
  • Biotechnology
  • Applied Microbiology and Biotechnology

Cite this

Performance enhancement of real-time detection of protozoan parasite, Cryptosporidium oocyst by a modified surface plasmon resonance (SPR) biosensor. / Kang, Chang Duk; Lee, Sang Wook; Park, Tai Hyun; Sim, Sang Jun.

In: Enzyme and Microbial Technology, Vol. 39, No. 3, 03.07.2006, p. 387-390.

Research output: Contribution to journalArticle

@article{4edb1a593eaf4e1685a948813767f521,
title = "Performance enhancement of real-time detection of protozoan parasite, Cryptosporidium oocyst by a modified surface plasmon resonance (SPR) biosensor",
abstract = "Surface plasmon resonance (SPR) biosensor based on mixed self-assembled monolayers (SAMs) was developed for real-time detection of Cryptosporidium oocyst. The flow type SPR biosensor consisting of subsequent binding of antibody and oocyst in flowing buffer system was able to detect Cryptosporidium parvum oocyst in real-time with a detection limit of 1 × 106 oocyst/ml. To enhance the sensitivity of real-time detection, the modified flow type SPR biosensor was developed, which consisted of the immunoreaction step between the biotin-antibody and oocysts followed by the binding step of antibody bound oocysts onto the sensor surface. Not only was the immunoreaction yield with batch immune reaction improved, but the accessibility of analytes to the sensor surface was also enhanced since the binding event for SPR signal generation was exchanged to biotin-streptavidin binding with high affinity. Consequently, the real-time detection limit of 1 × 102 oocyst/ml was obtained in the modified flow type biosensor.",
keywords = "Biosensor, Cryptosporidium oocyst, Real-time detection, Surface plasmon resonance",
author = "Kang, {Chang Duk} and Lee, {Sang Wook} and Park, {Tai Hyun} and Sim, {Sang Jun}",
year = "2006",
month = "7",
day = "3",
doi = "10.1016/j.enzmictec.2005.11.039",
language = "English",
volume = "39",
pages = "387--390",
journal = "Enzyme and Microbial Technology",
issn = "0141-0229",
publisher = "Elsevier Inc.",
number = "3",

}

TY - JOUR

T1 - Performance enhancement of real-time detection of protozoan parasite, Cryptosporidium oocyst by a modified surface plasmon resonance (SPR) biosensor

AU - Kang, Chang Duk

AU - Lee, Sang Wook

AU - Park, Tai Hyun

AU - Sim, Sang Jun

PY - 2006/7/3

Y1 - 2006/7/3

N2 - Surface plasmon resonance (SPR) biosensor based on mixed self-assembled monolayers (SAMs) was developed for real-time detection of Cryptosporidium oocyst. The flow type SPR biosensor consisting of subsequent binding of antibody and oocyst in flowing buffer system was able to detect Cryptosporidium parvum oocyst in real-time with a detection limit of 1 × 106 oocyst/ml. To enhance the sensitivity of real-time detection, the modified flow type SPR biosensor was developed, which consisted of the immunoreaction step between the biotin-antibody and oocysts followed by the binding step of antibody bound oocysts onto the sensor surface. Not only was the immunoreaction yield with batch immune reaction improved, but the accessibility of analytes to the sensor surface was also enhanced since the binding event for SPR signal generation was exchanged to biotin-streptavidin binding with high affinity. Consequently, the real-time detection limit of 1 × 102 oocyst/ml was obtained in the modified flow type biosensor.

AB - Surface plasmon resonance (SPR) biosensor based on mixed self-assembled monolayers (SAMs) was developed for real-time detection of Cryptosporidium oocyst. The flow type SPR biosensor consisting of subsequent binding of antibody and oocyst in flowing buffer system was able to detect Cryptosporidium parvum oocyst in real-time with a detection limit of 1 × 106 oocyst/ml. To enhance the sensitivity of real-time detection, the modified flow type SPR biosensor was developed, which consisted of the immunoreaction step between the biotin-antibody and oocysts followed by the binding step of antibody bound oocysts onto the sensor surface. Not only was the immunoreaction yield with batch immune reaction improved, but the accessibility of analytes to the sensor surface was also enhanced since the binding event for SPR signal generation was exchanged to biotin-streptavidin binding with high affinity. Consequently, the real-time detection limit of 1 × 102 oocyst/ml was obtained in the modified flow type biosensor.

KW - Biosensor

KW - Cryptosporidium oocyst

KW - Real-time detection

KW - Surface plasmon resonance

UR - http://www.scopus.com/inward/record.url?scp=33646797064&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33646797064&partnerID=8YFLogxK

U2 - 10.1016/j.enzmictec.2005.11.039

DO - 10.1016/j.enzmictec.2005.11.039

M3 - Article

AN - SCOPUS:33646797064

VL - 39

SP - 387

EP - 390

JO - Enzyme and Microbial Technology

JF - Enzyme and Microbial Technology

SN - 0141-0229

IS - 3

ER -