Performance improvement of self-humidifying PEM fuel cells using water injection at various start-up conditions

Dowon Cha, Wonseok Yang, Yong Chan Kim

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

A critical issue in self-humidifying proton electrolyte membrane (PEM) fuel cells is to achieve stable performance during start-up. In this study, the start-up characteristics of self-humidifying PEM fuel cells are investigated at various temperatures and voltages. Aquivion and Nafion are used as electrolytes for the performance comparison. Moreover, to overcome start-up failure, the direct water injection strategy is proposed and tested in the self-humidifying PEM fuel cell according to the injection side and amount of injected water. Generally, Aquivion membranes exhibit better start-up performance than Nafion membranes in the self-humidifying PEM fuel cell owing to its higher water absorption capability. The water injection into the anode side is more effective than that into the cathode side in achieving high stability and steady-state current density in the self-humidifying PEM fuel cells. With the water injection during start-up, the steady-state current density of the self-humidifying PEM fuel cell with Aquivion is 32% on average higher than that with Nafion. In addition, the optimal amount of water injection is dependent on the water absorption capability of the membrane at the start-up conditions.

Original languageEnglish
Pages (from-to)514-524
Number of pages11
JournalEnergy
Volume183
DOIs
Publication statusPublished - 2019 Sep 15

Fingerprint

Water injection
Fuel cells
Protons
Electrolytes
Membranes
Water absorption
Current density
Anodes
Cathodes
Electric potential

Keywords

  • Proton electrolyte membrane fuel cell
  • Self-humidification
  • Start-up
  • Water injection

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Building and Construction
  • Pollution
  • Mechanical Engineering
  • Industrial and Manufacturing Engineering
  • Electrical and Electronic Engineering

Cite this

Performance improvement of self-humidifying PEM fuel cells using water injection at various start-up conditions. / Cha, Dowon; Yang, Wonseok; Kim, Yong Chan.

In: Energy, Vol. 183, 15.09.2019, p. 514-524.

Research output: Contribution to journalArticle

@article{65059613766f4995a073851eb7f829b5,
title = "Performance improvement of self-humidifying PEM fuel cells using water injection at various start-up conditions",
abstract = "A critical issue in self-humidifying proton electrolyte membrane (PEM) fuel cells is to achieve stable performance during start-up. In this study, the start-up characteristics of self-humidifying PEM fuel cells are investigated at various temperatures and voltages. Aquivion and Nafion are used as electrolytes for the performance comparison. Moreover, to overcome start-up failure, the direct water injection strategy is proposed and tested in the self-humidifying PEM fuel cell according to the injection side and amount of injected water. Generally, Aquivion membranes exhibit better start-up performance than Nafion membranes in the self-humidifying PEM fuel cell owing to its higher water absorption capability. The water injection into the anode side is more effective than that into the cathode side in achieving high stability and steady-state current density in the self-humidifying PEM fuel cells. With the water injection during start-up, the steady-state current density of the self-humidifying PEM fuel cell with Aquivion is 32{\%} on average higher than that with Nafion. In addition, the optimal amount of water injection is dependent on the water absorption capability of the membrane at the start-up conditions.",
keywords = "Proton electrolyte membrane fuel cell, Self-humidification, Start-up, Water injection",
author = "Dowon Cha and Wonseok Yang and Kim, {Yong Chan}",
year = "2019",
month = "9",
day = "15",
doi = "10.1016/j.energy.2019.06.154",
language = "English",
volume = "183",
pages = "514--524",
journal = "Energy",
issn = "0360-5442",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - Performance improvement of self-humidifying PEM fuel cells using water injection at various start-up conditions

AU - Cha, Dowon

AU - Yang, Wonseok

AU - Kim, Yong Chan

PY - 2019/9/15

Y1 - 2019/9/15

N2 - A critical issue in self-humidifying proton electrolyte membrane (PEM) fuel cells is to achieve stable performance during start-up. In this study, the start-up characteristics of self-humidifying PEM fuel cells are investigated at various temperatures and voltages. Aquivion and Nafion are used as electrolytes for the performance comparison. Moreover, to overcome start-up failure, the direct water injection strategy is proposed and tested in the self-humidifying PEM fuel cell according to the injection side and amount of injected water. Generally, Aquivion membranes exhibit better start-up performance than Nafion membranes in the self-humidifying PEM fuel cell owing to its higher water absorption capability. The water injection into the anode side is more effective than that into the cathode side in achieving high stability and steady-state current density in the self-humidifying PEM fuel cells. With the water injection during start-up, the steady-state current density of the self-humidifying PEM fuel cell with Aquivion is 32% on average higher than that with Nafion. In addition, the optimal amount of water injection is dependent on the water absorption capability of the membrane at the start-up conditions.

AB - A critical issue in self-humidifying proton electrolyte membrane (PEM) fuel cells is to achieve stable performance during start-up. In this study, the start-up characteristics of self-humidifying PEM fuel cells are investigated at various temperatures and voltages. Aquivion and Nafion are used as electrolytes for the performance comparison. Moreover, to overcome start-up failure, the direct water injection strategy is proposed and tested in the self-humidifying PEM fuel cell according to the injection side and amount of injected water. Generally, Aquivion membranes exhibit better start-up performance than Nafion membranes in the self-humidifying PEM fuel cell owing to its higher water absorption capability. The water injection into the anode side is more effective than that into the cathode side in achieving high stability and steady-state current density in the self-humidifying PEM fuel cells. With the water injection during start-up, the steady-state current density of the self-humidifying PEM fuel cell with Aquivion is 32% on average higher than that with Nafion. In addition, the optimal amount of water injection is dependent on the water absorption capability of the membrane at the start-up conditions.

KW - Proton electrolyte membrane fuel cell

KW - Self-humidification

KW - Start-up

KW - Water injection

UR - http://www.scopus.com/inward/record.url?scp=85068108685&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85068108685&partnerID=8YFLogxK

U2 - 10.1016/j.energy.2019.06.154

DO - 10.1016/j.energy.2019.06.154

M3 - Article

AN - SCOPUS:85068108685

VL - 183

SP - 514

EP - 524

JO - Energy

JF - Energy

SN - 0360-5442

ER -