Performance prediction of centrifugal compressor for drop-in testing using low global warming potential alternative refrigerants and performance test codes

Joo Hoon Park, Youhwan Shin, Jin Taek Chung

Research output: Contribution to journalArticle

Abstract

As environmental regulations to stall global warming are strengthened around the world, studies using newly developed low global warming potential (GWP) alternative refrigerants are increasing. In this study, substitute refrigerants, R-1234ze (E) and R-1233zd (E), were used in the centrifugal compressor of an R-134a 2-stage centrifugal chiller with a fixed rotational speed. Performance predictions and thermodynamic analyses of the centrifugal compressor for drop-in testing were performed. A performance prediction method based on the existing ASME PTC-10 performance test code was proposed. The proposed method yielded the expected operating area and operating point of the centrifugal compressor with alternative refrigerants. The thermodynamic performance of the first and second stages of the centrifugal compressor was calculated as the polytropic state. To verify the suitability of the proposed method, the drop-in test results of the two alternative refrigerants were compared. The predicted operating range based on the permissible deviation of ASME PTC-10 confirmed that the temperature difference was very small at the same efficiency. Because the drop-in test of R-1234ze (E) was performed within the expected operating range, the centrifugal compressor using R-1234ze (E) is considered well predicted. However, the predictions of the operating point and operating range of R-1233zd (E) were lower than those of the drop-in test. The proposed performance prediction method will assist in understanding thermodynamic performance at the expected operating point and operating area of a centrifugal compressor using alternative gases based on limited design and structure information.

Original languageEnglish
Article number20493
JournalEnergies
Volume10
Issue number12
DOIs
Publication statusPublished - 2017 Dec 1

Fingerprint

Centrifugal compressors
Global warming
Refrigerants
Testing
Thermodynamics
Environmental regulations
Gases

Keywords

  • Centrifugal compressor
  • Drop-in test
  • Low-GWP alternative refrigerant
  • Operating point
  • Operating range
  • Performance test code
  • R-1233zd (E)
  • R-1234ze (E)

ASJC Scopus subject areas

  • Computer Science(all)
  • Renewable Energy, Sustainability and the Environment
  • Energy Engineering and Power Technology
  • Energy (miscellaneous)

Cite this

Performance prediction of centrifugal compressor for drop-in testing using low global warming potential alternative refrigerants and performance test codes. / Park, Joo Hoon; Shin, Youhwan; Chung, Jin Taek.

In: Energies, Vol. 10, No. 12, 20493, 01.12.2017.

Research output: Contribution to journalArticle

@article{a4a124ff982841ba9039dda2e8bef937,
title = "Performance prediction of centrifugal compressor for drop-in testing using low global warming potential alternative refrigerants and performance test codes",
abstract = "As environmental regulations to stall global warming are strengthened around the world, studies using newly developed low global warming potential (GWP) alternative refrigerants are increasing. In this study, substitute refrigerants, R-1234ze (E) and R-1233zd (E), were used in the centrifugal compressor of an R-134a 2-stage centrifugal chiller with a fixed rotational speed. Performance predictions and thermodynamic analyses of the centrifugal compressor for drop-in testing were performed. A performance prediction method based on the existing ASME PTC-10 performance test code was proposed. The proposed method yielded the expected operating area and operating point of the centrifugal compressor with alternative refrigerants. The thermodynamic performance of the first and second stages of the centrifugal compressor was calculated as the polytropic state. To verify the suitability of the proposed method, the drop-in test results of the two alternative refrigerants were compared. The predicted operating range based on the permissible deviation of ASME PTC-10 confirmed that the temperature difference was very small at the same efficiency. Because the drop-in test of R-1234ze (E) was performed within the expected operating range, the centrifugal compressor using R-1234ze (E) is considered well predicted. However, the predictions of the operating point and operating range of R-1233zd (E) were lower than those of the drop-in test. The proposed performance prediction method will assist in understanding thermodynamic performance at the expected operating point and operating area of a centrifugal compressor using alternative gases based on limited design and structure information.",
keywords = "Centrifugal compressor, Drop-in test, Low-GWP alternative refrigerant, Operating point, Operating range, Performance test code, R-1233zd (E), R-1234ze (E)",
author = "Park, {Joo Hoon} and Youhwan Shin and Chung, {Jin Taek}",
year = "2017",
month = "12",
day = "1",
doi = "10.3390/en10122043",
language = "English",
volume = "10",
journal = "Energies",
issn = "1996-1073",
publisher = "Multidisciplinary Digital Publishing Institute (MDPI)",
number = "12",

}

TY - JOUR

T1 - Performance prediction of centrifugal compressor for drop-in testing using low global warming potential alternative refrigerants and performance test codes

AU - Park, Joo Hoon

AU - Shin, Youhwan

AU - Chung, Jin Taek

PY - 2017/12/1

Y1 - 2017/12/1

N2 - As environmental regulations to stall global warming are strengthened around the world, studies using newly developed low global warming potential (GWP) alternative refrigerants are increasing. In this study, substitute refrigerants, R-1234ze (E) and R-1233zd (E), were used in the centrifugal compressor of an R-134a 2-stage centrifugal chiller with a fixed rotational speed. Performance predictions and thermodynamic analyses of the centrifugal compressor for drop-in testing were performed. A performance prediction method based on the existing ASME PTC-10 performance test code was proposed. The proposed method yielded the expected operating area and operating point of the centrifugal compressor with alternative refrigerants. The thermodynamic performance of the first and second stages of the centrifugal compressor was calculated as the polytropic state. To verify the suitability of the proposed method, the drop-in test results of the two alternative refrigerants were compared. The predicted operating range based on the permissible deviation of ASME PTC-10 confirmed that the temperature difference was very small at the same efficiency. Because the drop-in test of R-1234ze (E) was performed within the expected operating range, the centrifugal compressor using R-1234ze (E) is considered well predicted. However, the predictions of the operating point and operating range of R-1233zd (E) were lower than those of the drop-in test. The proposed performance prediction method will assist in understanding thermodynamic performance at the expected operating point and operating area of a centrifugal compressor using alternative gases based on limited design and structure information.

AB - As environmental regulations to stall global warming are strengthened around the world, studies using newly developed low global warming potential (GWP) alternative refrigerants are increasing. In this study, substitute refrigerants, R-1234ze (E) and R-1233zd (E), were used in the centrifugal compressor of an R-134a 2-stage centrifugal chiller with a fixed rotational speed. Performance predictions and thermodynamic analyses of the centrifugal compressor for drop-in testing were performed. A performance prediction method based on the existing ASME PTC-10 performance test code was proposed. The proposed method yielded the expected operating area and operating point of the centrifugal compressor with alternative refrigerants. The thermodynamic performance of the first and second stages of the centrifugal compressor was calculated as the polytropic state. To verify the suitability of the proposed method, the drop-in test results of the two alternative refrigerants were compared. The predicted operating range based on the permissible deviation of ASME PTC-10 confirmed that the temperature difference was very small at the same efficiency. Because the drop-in test of R-1234ze (E) was performed within the expected operating range, the centrifugal compressor using R-1234ze (E) is considered well predicted. However, the predictions of the operating point and operating range of R-1233zd (E) were lower than those of the drop-in test. The proposed performance prediction method will assist in understanding thermodynamic performance at the expected operating point and operating area of a centrifugal compressor using alternative gases based on limited design and structure information.

KW - Centrifugal compressor

KW - Drop-in test

KW - Low-GWP alternative refrigerant

KW - Operating point

KW - Operating range

KW - Performance test code

KW - R-1233zd (E)

KW - R-1234ze (E)

UR - http://www.scopus.com/inward/record.url?scp=85044395561&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85044395561&partnerID=8YFLogxK

U2 - 10.3390/en10122043

DO - 10.3390/en10122043

M3 - Article

AN - SCOPUS:85044395561

VL - 10

JO - Energies

JF - Energies

SN - 1996-1073

IS - 12

M1 - 20493

ER -