Performances of a protector against scattered radiation during intraoperative use of a C-arm fluoroscope

Ki Hyuk Sung, Young Jun Jung, Soon Sun Kwon, Gye Wang Lee, Chin Youb Chung, Kyoung Min Lee, Hyemi Cha, Moon Seok Park, Kisung Lee

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

The scattered radiation protector for mobile x-ray systems, Creative Valuable Protector-2, has been recently developed. However, there have been no studies investigating the effects of this device. We aim to investigate the effects of the scattered radiation protector on the equivalent doses from scattered radiation delivered to radiosensitive organs while simulating spine surgery using a C-arm fluoroscope. Chest and rando phantoms were used to simulate a patient and a surgeon in this study. The equivalent dose from scattered radiation to radiosensitive organs was measured in four different situations according to the use of the scattered radiation protector and the C-arm configuration. To compare the quality of the images with and without the scattered radiation protector, an acryl step phantom with five steps was used, and the contrast resolution of each step was calculated. The equivalent dose from the scattered radiation to the surgeon's eye, thyroid, and gonad decreased significantly by using the scattered radiation protector for both the Posteroanterior (PA) (p < 0.001) and Anteroposterior (AP) (p < 0.001) C-arm configurations. The installation of the scattered radiation protector also reduced the direct radiation dose to the chest phantom. A scattered map showed that scattered radiation doses decreased by approximately 50% for the PA configuration and 75% for the AP configuration by using the scattered radiation protector. Before and after installation of the scattered radiation protector, the contrast resolution of each adjacent step area was 0.025-0.404 and 0.216-0.421. The scattered radiation protector was effective in reducing not only the equivalent dose from scattered radiation to the surgeon's radiosensitive organs, but also the direct radiation dose to the patient. This was all achieved without decreasing the quality of the C-arm fluoroscopic images.

Original languageEnglish
Pages (from-to)629-640
Number of pages12
JournalJournal of Radiological Protection
Volume36
Issue number3
DOIs
Publication statusPublished - 2016 Sep 1

Fingerprint

Arm
Radiation
radiation
Thorax
Radiation Effects
Gonads
Thyroid Gland
Spine
X-Rays
equivalent dose
Equipment and Supplies

ASJC Scopus subject areas

  • Waste Management and Disposal
  • Public Health, Environmental and Occupational Health

Cite this

Performances of a protector against scattered radiation during intraoperative use of a C-arm fluoroscope. / Sung, Ki Hyuk; Jung, Young Jun; Kwon, Soon Sun; Lee, Gye Wang; Youb Chung, Chin; Lee, Kyoung Min; Cha, Hyemi; Park, Moon Seok; Lee, Kisung.

In: Journal of Radiological Protection, Vol. 36, No. 3, 01.09.2016, p. 629-640.

Research output: Contribution to journalArticle

Sung, Ki Hyuk ; Jung, Young Jun ; Kwon, Soon Sun ; Lee, Gye Wang ; Youb Chung, Chin ; Lee, Kyoung Min ; Cha, Hyemi ; Park, Moon Seok ; Lee, Kisung. / Performances of a protector against scattered radiation during intraoperative use of a C-arm fluoroscope. In: Journal of Radiological Protection. 2016 ; Vol. 36, No. 3. pp. 629-640.
@article{1629466098ba4b21a4751d52f2ecdb41,
title = "Performances of a protector against scattered radiation during intraoperative use of a C-arm fluoroscope",
abstract = "The scattered radiation protector for mobile x-ray systems, Creative Valuable Protector-2, has been recently developed. However, there have been no studies investigating the effects of this device. We aim to investigate the effects of the scattered radiation protector on the equivalent doses from scattered radiation delivered to radiosensitive organs while simulating spine surgery using a C-arm fluoroscope. Chest and rando phantoms were used to simulate a patient and a surgeon in this study. The equivalent dose from scattered radiation to radiosensitive organs was measured in four different situations according to the use of the scattered radiation protector and the C-arm configuration. To compare the quality of the images with and without the scattered radiation protector, an acryl step phantom with five steps was used, and the contrast resolution of each step was calculated. The equivalent dose from the scattered radiation to the surgeon's eye, thyroid, and gonad decreased significantly by using the scattered radiation protector for both the Posteroanterior (PA) (p < 0.001) and Anteroposterior (AP) (p < 0.001) C-arm configurations. The installation of the scattered radiation protector also reduced the direct radiation dose to the chest phantom. A scattered map showed that scattered radiation doses decreased by approximately 50{\%} for the PA configuration and 75{\%} for the AP configuration by using the scattered radiation protector. Before and after installation of the scattered radiation protector, the contrast resolution of each adjacent step area was 0.025-0.404 and 0.216-0.421. The scattered radiation protector was effective in reducing not only the equivalent dose from scattered radiation to the surgeon's radiosensitive organs, but also the direct radiation dose to the patient. This was all achieved without decreasing the quality of the C-arm fluoroscopic images.",
author = "Sung, {Ki Hyuk} and Jung, {Young Jun} and Kwon, {Soon Sun} and Lee, {Gye Wang} and {Youb Chung}, Chin and Lee, {Kyoung Min} and Hyemi Cha and Park, {Moon Seok} and Kisung Lee",
year = "2016",
month = "9",
day = "1",
doi = "10.1088/0952-4746/36/3/629",
language = "English",
volume = "36",
pages = "629--640",
journal = "Journal of Radiological Protection",
issn = "0952-4746",
publisher = "IOP Publishing Ltd.",
number = "3",

}

TY - JOUR

T1 - Performances of a protector against scattered radiation during intraoperative use of a C-arm fluoroscope

AU - Sung, Ki Hyuk

AU - Jung, Young Jun

AU - Kwon, Soon Sun

AU - Lee, Gye Wang

AU - Youb Chung, Chin

AU - Lee, Kyoung Min

AU - Cha, Hyemi

AU - Park, Moon Seok

AU - Lee, Kisung

PY - 2016/9/1

Y1 - 2016/9/1

N2 - The scattered radiation protector for mobile x-ray systems, Creative Valuable Protector-2, has been recently developed. However, there have been no studies investigating the effects of this device. We aim to investigate the effects of the scattered radiation protector on the equivalent doses from scattered radiation delivered to radiosensitive organs while simulating spine surgery using a C-arm fluoroscope. Chest and rando phantoms were used to simulate a patient and a surgeon in this study. The equivalent dose from scattered radiation to radiosensitive organs was measured in four different situations according to the use of the scattered radiation protector and the C-arm configuration. To compare the quality of the images with and without the scattered radiation protector, an acryl step phantom with five steps was used, and the contrast resolution of each step was calculated. The equivalent dose from the scattered radiation to the surgeon's eye, thyroid, and gonad decreased significantly by using the scattered radiation protector for both the Posteroanterior (PA) (p < 0.001) and Anteroposterior (AP) (p < 0.001) C-arm configurations. The installation of the scattered radiation protector also reduced the direct radiation dose to the chest phantom. A scattered map showed that scattered radiation doses decreased by approximately 50% for the PA configuration and 75% for the AP configuration by using the scattered radiation protector. Before and after installation of the scattered radiation protector, the contrast resolution of each adjacent step area was 0.025-0.404 and 0.216-0.421. The scattered radiation protector was effective in reducing not only the equivalent dose from scattered radiation to the surgeon's radiosensitive organs, but also the direct radiation dose to the patient. This was all achieved without decreasing the quality of the C-arm fluoroscopic images.

AB - The scattered radiation protector for mobile x-ray systems, Creative Valuable Protector-2, has been recently developed. However, there have been no studies investigating the effects of this device. We aim to investigate the effects of the scattered radiation protector on the equivalent doses from scattered radiation delivered to radiosensitive organs while simulating spine surgery using a C-arm fluoroscope. Chest and rando phantoms were used to simulate a patient and a surgeon in this study. The equivalent dose from scattered radiation to radiosensitive organs was measured in four different situations according to the use of the scattered radiation protector and the C-arm configuration. To compare the quality of the images with and without the scattered radiation protector, an acryl step phantom with five steps was used, and the contrast resolution of each step was calculated. The equivalent dose from the scattered radiation to the surgeon's eye, thyroid, and gonad decreased significantly by using the scattered radiation protector for both the Posteroanterior (PA) (p < 0.001) and Anteroposterior (AP) (p < 0.001) C-arm configurations. The installation of the scattered radiation protector also reduced the direct radiation dose to the chest phantom. A scattered map showed that scattered radiation doses decreased by approximately 50% for the PA configuration and 75% for the AP configuration by using the scattered radiation protector. Before and after installation of the scattered radiation protector, the contrast resolution of each adjacent step area was 0.025-0.404 and 0.216-0.421. The scattered radiation protector was effective in reducing not only the equivalent dose from scattered radiation to the surgeon's radiosensitive organs, but also the direct radiation dose to the patient. This was all achieved without decreasing the quality of the C-arm fluoroscopic images.

UR - http://www.scopus.com/inward/record.url?scp=84995944902&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84995944902&partnerID=8YFLogxK

U2 - 10.1088/0952-4746/36/3/629

DO - 10.1088/0952-4746/36/3/629

M3 - Article

VL - 36

SP - 629

EP - 640

JO - Journal of Radiological Protection

JF - Journal of Radiological Protection

SN - 0952-4746

IS - 3

ER -