Phase-sensitive, dual-acquisition, single-slab, 3D, turbo-spin-echo pulse sequence for simultaneous T 2-weighted and fluid-attenuated whole-brain imaging

Jaeseok Park, Suhyung Park, Eung Yeop Kim, Jin Suck Suh

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Conventional T 2-weighted turbo/fast spin echo imaging is clinically accepted as the most sensitive method to detect brain lesions but generates a high signal intensity of cerebrospinal fluid (CSF), yielding diagnostic ambiguity for lesions close to CSF. Fluid-attenuated inversion recovery can be an alternative, selectively eliminating CSF signals. However, a long time of inversion, which is required for CSF suppression, increases imaging time substantially and thereby limits spatial resolution. The purpose of this work is to develop a phase-sensitive, dual-acquisition, single-slab, three-dimensional, turbo/fast spin echo imaging, simultaneously achieving both conventional T 2-weighted and fluid-attenuated inversion recovery-like high-resolution whole-brain images in a single pulse sequence, without an apparent increase of imaging time. Dual acquisition in each time of repetition is performed, wherein an in phase between CSF and brain tissues is achieved in the first acquisition, while an opposed phase, which is established by a sequence of a long refocusing pulse train with variable flip angles, a composite flip-down restore pulse train, and a short time of delay, is attained in the second acquisition. A CSF-suppressed image is then reconstructed by weighted averaging the in- and opposed-phase images. Numerical simulations and in vivo experiments are performed, demonstrating that this single pulse sequence may replace both conventional T 2-weighted imaging and fluid-attenuated inversion recovery.

Original languageEnglish
Pages (from-to)1422-1430
Number of pages9
JournalMagnetic Resonance in Medicine
Volume63
Issue number5
DOIs
Publication statusPublished - 2010 May
Externally publishedYes

Fingerprint

Neuroimaging
Cerebrospinal Fluid
Brain
Magnetic Resonance Imaging

Keywords

  • Fluid-attenuated
  • Magnetic resonance imaging
  • MRI
  • Phase-sensitive
  • Spin echo
  • Three-dimensional
  • Variable flip angle

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Medicine(all)

Cite this

Phase-sensitive, dual-acquisition, single-slab, 3D, turbo-spin-echo pulse sequence for simultaneous T 2-weighted and fluid-attenuated whole-brain imaging. / Park, Jaeseok; Park, Suhyung; Kim, Eung Yeop; Suh, Jin Suck.

In: Magnetic Resonance in Medicine, Vol. 63, No. 5, 05.2010, p. 1422-1430.

Research output: Contribution to journalArticle

@article{4022a58d682c47a5b6dd14adf05326ee,
title = "Phase-sensitive, dual-acquisition, single-slab, 3D, turbo-spin-echo pulse sequence for simultaneous T 2-weighted and fluid-attenuated whole-brain imaging",
abstract = "Conventional T 2-weighted turbo/fast spin echo imaging is clinically accepted as the most sensitive method to detect brain lesions but generates a high signal intensity of cerebrospinal fluid (CSF), yielding diagnostic ambiguity for lesions close to CSF. Fluid-attenuated inversion recovery can be an alternative, selectively eliminating CSF signals. However, a long time of inversion, which is required for CSF suppression, increases imaging time substantially and thereby limits spatial resolution. The purpose of this work is to develop a phase-sensitive, dual-acquisition, single-slab, three-dimensional, turbo/fast spin echo imaging, simultaneously achieving both conventional T 2-weighted and fluid-attenuated inversion recovery-like high-resolution whole-brain images in a single pulse sequence, without an apparent increase of imaging time. Dual acquisition in each time of repetition is performed, wherein an in phase between CSF and brain tissues is achieved in the first acquisition, while an opposed phase, which is established by a sequence of a long refocusing pulse train with variable flip angles, a composite flip-down restore pulse train, and a short time of delay, is attained in the second acquisition. A CSF-suppressed image is then reconstructed by weighted averaging the in- and opposed-phase images. Numerical simulations and in vivo experiments are performed, demonstrating that this single pulse sequence may replace both conventional T 2-weighted imaging and fluid-attenuated inversion recovery.",
keywords = "Fluid-attenuated, Magnetic resonance imaging, MRI, Phase-sensitive, Spin echo, Three-dimensional, Variable flip angle",
author = "Jaeseok Park and Suhyung Park and Kim, {Eung Yeop} and Suh, {Jin Suck}",
year = "2010",
month = "5",
doi = "10.1002/mrm.22317",
language = "English",
volume = "63",
pages = "1422--1430",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "5",

}

TY - JOUR

T1 - Phase-sensitive, dual-acquisition, single-slab, 3D, turbo-spin-echo pulse sequence for simultaneous T 2-weighted and fluid-attenuated whole-brain imaging

AU - Park, Jaeseok

AU - Park, Suhyung

AU - Kim, Eung Yeop

AU - Suh, Jin Suck

PY - 2010/5

Y1 - 2010/5

N2 - Conventional T 2-weighted turbo/fast spin echo imaging is clinically accepted as the most sensitive method to detect brain lesions but generates a high signal intensity of cerebrospinal fluid (CSF), yielding diagnostic ambiguity for lesions close to CSF. Fluid-attenuated inversion recovery can be an alternative, selectively eliminating CSF signals. However, a long time of inversion, which is required for CSF suppression, increases imaging time substantially and thereby limits spatial resolution. The purpose of this work is to develop a phase-sensitive, dual-acquisition, single-slab, three-dimensional, turbo/fast spin echo imaging, simultaneously achieving both conventional T 2-weighted and fluid-attenuated inversion recovery-like high-resolution whole-brain images in a single pulse sequence, without an apparent increase of imaging time. Dual acquisition in each time of repetition is performed, wherein an in phase between CSF and brain tissues is achieved in the first acquisition, while an opposed phase, which is established by a sequence of a long refocusing pulse train with variable flip angles, a composite flip-down restore pulse train, and a short time of delay, is attained in the second acquisition. A CSF-suppressed image is then reconstructed by weighted averaging the in- and opposed-phase images. Numerical simulations and in vivo experiments are performed, demonstrating that this single pulse sequence may replace both conventional T 2-weighted imaging and fluid-attenuated inversion recovery.

AB - Conventional T 2-weighted turbo/fast spin echo imaging is clinically accepted as the most sensitive method to detect brain lesions but generates a high signal intensity of cerebrospinal fluid (CSF), yielding diagnostic ambiguity for lesions close to CSF. Fluid-attenuated inversion recovery can be an alternative, selectively eliminating CSF signals. However, a long time of inversion, which is required for CSF suppression, increases imaging time substantially and thereby limits spatial resolution. The purpose of this work is to develop a phase-sensitive, dual-acquisition, single-slab, three-dimensional, turbo/fast spin echo imaging, simultaneously achieving both conventional T 2-weighted and fluid-attenuated inversion recovery-like high-resolution whole-brain images in a single pulse sequence, without an apparent increase of imaging time. Dual acquisition in each time of repetition is performed, wherein an in phase between CSF and brain tissues is achieved in the first acquisition, while an opposed phase, which is established by a sequence of a long refocusing pulse train with variable flip angles, a composite flip-down restore pulse train, and a short time of delay, is attained in the second acquisition. A CSF-suppressed image is then reconstructed by weighted averaging the in- and opposed-phase images. Numerical simulations and in vivo experiments are performed, demonstrating that this single pulse sequence may replace both conventional T 2-weighted imaging and fluid-attenuated inversion recovery.

KW - Fluid-attenuated

KW - Magnetic resonance imaging

KW - MRI

KW - Phase-sensitive

KW - Spin echo

KW - Three-dimensional

KW - Variable flip angle

UR - http://www.scopus.com/inward/record.url?scp=77955302166&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77955302166&partnerID=8YFLogxK

U2 - 10.1002/mrm.22317

DO - 10.1002/mrm.22317

M3 - Article

C2 - 20432315

AN - SCOPUS:77955302166

VL - 63

SP - 1422

EP - 1430

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 5

ER -