Pre-concentration without changes in ph in an open reservoir utilizing ion concentration polarization

Youngkyu Cho, David Wonbin Lim, Junghyo Yoon, Jaeho Kim, Jeong Hoon Lee, Seok Chung

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Pre-concentration of liquid sample without pH change is essential for diagnosis in patient samples with low concentration virus or biological molecules. Target molecule's isoelectric point (PI) value and optimal pH should be stable in antibody-antigen reaction [1], to facilitate robust and accurate detection. Previously, pre-concentration using a buffer drain technique is developed for concentrating protein. Previous technique has a problem of changing pH of sample when utilizing electric field in the sample reservoir [2]. Here, we developed a simple micro-fluidic device, which can concentrate particle without changes in pH, based PDMS utilizing ion concentration polarization (ICP) by ion selective layer made of Nafion [3].

Original languageEnglish
Title of host publicationMicroTAS 2015 - 19th International Conference on Miniaturized Systems for Chemistry and Life Sciences
PublisherChemical and Biological Microsystems Society
Pages1205-1207
Number of pages3
ISBN (Electronic)9780979806483
Publication statusPublished - 2015
Event19th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2015 - Gyeongju, Korea, Republic of
Duration: 2015 Oct 252015 Oct 29

Other

Other19th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2015
CountryKorea, Republic of
CityGyeongju
Period15/10/2515/10/29

Fingerprint

Antigen-antibody reactions
Fluidic devices
Polarization
Molecules
Ions
Viruses
Electric fields
Proteins
Liquids

Keywords

  • Ion concentration polarization
  • Microfluidic
  • Pre-concentration

ASJC Scopus subject areas

  • Control and Systems Engineering

Cite this

Cho, Y., Lim, D. W., Yoon, J., Kim, J., Lee, J. H., & Chung, S. (2015). Pre-concentration without changes in ph in an open reservoir utilizing ion concentration polarization. In MicroTAS 2015 - 19th International Conference on Miniaturized Systems for Chemistry and Life Sciences (pp. 1205-1207). Chemical and Biological Microsystems Society.

Pre-concentration without changes in ph in an open reservoir utilizing ion concentration polarization. / Cho, Youngkyu; Lim, David Wonbin; Yoon, Junghyo; Kim, Jaeho; Lee, Jeong Hoon; Chung, Seok.

MicroTAS 2015 - 19th International Conference on Miniaturized Systems for Chemistry and Life Sciences. Chemical and Biological Microsystems Society, 2015. p. 1205-1207.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Cho, Y, Lim, DW, Yoon, J, Kim, J, Lee, JH & Chung, S 2015, Pre-concentration without changes in ph in an open reservoir utilizing ion concentration polarization. in MicroTAS 2015 - 19th International Conference on Miniaturized Systems for Chemistry and Life Sciences. Chemical and Biological Microsystems Society, pp. 1205-1207, 19th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2015, Gyeongju, Korea, Republic of, 15/10/25.
Cho Y, Lim DW, Yoon J, Kim J, Lee JH, Chung S. Pre-concentration without changes in ph in an open reservoir utilizing ion concentration polarization. In MicroTAS 2015 - 19th International Conference on Miniaturized Systems for Chemistry and Life Sciences. Chemical and Biological Microsystems Society. 2015. p. 1205-1207
Cho, Youngkyu ; Lim, David Wonbin ; Yoon, Junghyo ; Kim, Jaeho ; Lee, Jeong Hoon ; Chung, Seok. / Pre-concentration without changes in ph in an open reservoir utilizing ion concentration polarization. MicroTAS 2015 - 19th International Conference on Miniaturized Systems for Chemistry and Life Sciences. Chemical and Biological Microsystems Society, 2015. pp. 1205-1207
@inproceedings{60eb241c42034e5f98d5ac40f5209efb,
title = "Pre-concentration without changes in ph in an open reservoir utilizing ion concentration polarization",
abstract = "Pre-concentration of liquid sample without pH change is essential for diagnosis in patient samples with low concentration virus or biological molecules. Target molecule's isoelectric point (PI) value and optimal pH should be stable in antibody-antigen reaction [1], to facilitate robust and accurate detection. Previously, pre-concentration using a buffer drain technique is developed for concentrating protein. Previous technique has a problem of changing pH of sample when utilizing electric field in the sample reservoir [2]. Here, we developed a simple micro-fluidic device, which can concentrate particle without changes in pH, based PDMS utilizing ion concentration polarization (ICP) by ion selective layer made of Nafion [3].",
keywords = "Ion concentration polarization, Microfluidic, Pre-concentration",
author = "Youngkyu Cho and Lim, {David Wonbin} and Junghyo Yoon and Jaeho Kim and Lee, {Jeong Hoon} and Seok Chung",
year = "2015",
language = "English",
pages = "1205--1207",
booktitle = "MicroTAS 2015 - 19th International Conference on Miniaturized Systems for Chemistry and Life Sciences",
publisher = "Chemical and Biological Microsystems Society",

}

TY - GEN

T1 - Pre-concentration without changes in ph in an open reservoir utilizing ion concentration polarization

AU - Cho, Youngkyu

AU - Lim, David Wonbin

AU - Yoon, Junghyo

AU - Kim, Jaeho

AU - Lee, Jeong Hoon

AU - Chung, Seok

PY - 2015

Y1 - 2015

N2 - Pre-concentration of liquid sample without pH change is essential for diagnosis in patient samples with low concentration virus or biological molecules. Target molecule's isoelectric point (PI) value and optimal pH should be stable in antibody-antigen reaction [1], to facilitate robust and accurate detection. Previously, pre-concentration using a buffer drain technique is developed for concentrating protein. Previous technique has a problem of changing pH of sample when utilizing electric field in the sample reservoir [2]. Here, we developed a simple micro-fluidic device, which can concentrate particle without changes in pH, based PDMS utilizing ion concentration polarization (ICP) by ion selective layer made of Nafion [3].

AB - Pre-concentration of liquid sample without pH change is essential for diagnosis in patient samples with low concentration virus or biological molecules. Target molecule's isoelectric point (PI) value and optimal pH should be stable in antibody-antigen reaction [1], to facilitate robust and accurate detection. Previously, pre-concentration using a buffer drain technique is developed for concentrating protein. Previous technique has a problem of changing pH of sample when utilizing electric field in the sample reservoir [2]. Here, we developed a simple micro-fluidic device, which can concentrate particle without changes in pH, based PDMS utilizing ion concentration polarization (ICP) by ion selective layer made of Nafion [3].

KW - Ion concentration polarization

KW - Microfluidic

KW - Pre-concentration

UR - http://www.scopus.com/inward/record.url?scp=84983243410&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84983243410&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84983243410

SP - 1205

EP - 1207

BT - MicroTAS 2015 - 19th International Conference on Miniaturized Systems for Chemistry and Life Sciences

PB - Chemical and Biological Microsystems Society

ER -