A micro-machined gyro chip of gyroscope is normally packaged in specific vacuum level to get the specific quality factor(Q-factor). If the Q-factor is too high, frequency tuning and the approximate matching between driving and sensing comb structure become difficult, and if the Q-factor is too low, its sensitivity decreases. The optimum Q-factor of our gyro chip design is 4000 range. To get this range, we measured the drive mode Q-factor as vacuum level of our gyro chip and we found that the vacuum level of the desired Q-factor 4000 is in the range of 740 mTorr. Based on this data, we fabricate the wafer level package gyro chip of the desired Q-factor by controlled the basic pressure of package bonding chamber just prior to the bonding process. After wafer level package process, we measured Q-factor of whole samples. Among 804 samples, 502 packaged gyro chips are worked and the Q-factor of 67% samples is between 3500 and 4500 range.

Original languageEnglish
Pages (from-to)948-952
Number of pages5
JournalMicroelectronics Reliability
Volume48
Issue number6
DOIs
Publication statusPublished - 2008 Jun 1

Fingerprint

Gyroscopes
gyroscopes
Q factors
Vacuum
vacuum
chips
Tuning
wafers
chambers
tuning
sensitivity

ASJC Scopus subject areas

  • Control and Systems Engineering
  • Electrical and Electronic Engineering

Cite this

Quality factor measurement of micro gyroscope structure according to vacuum level and desired Q-factor range package method. / Kim, Jong Seok; Lee, Sang Woo; Jung, Kyu Dong; Kim, Woon Bae; Choa, Sung Hoon; Ju, Byeong Kwon.

In: Microelectronics Reliability, Vol. 48, No. 6, 01.06.2008, p. 948-952.

Research output: Contribution to journalArticle

Kim, Jong Seok ; Lee, Sang Woo ; Jung, Kyu Dong ; Kim, Woon Bae ; Choa, Sung Hoon ; Ju, Byeong Kwon. / Quality factor measurement of micro gyroscope structure according to vacuum level and desired Q-factor range package method. In: Microelectronics Reliability. 2008 ; Vol. 48, No. 6. pp. 948-952.
@article{d8b5855bbfa14412a3560db237c8362a,
title = "Quality factor measurement of micro gyroscope structure according to vacuum level and desired Q-factor range package method",
abstract = "A micro-machined gyro chip of gyroscope is normally packaged in specific vacuum level to get the specific quality factor(Q-factor). If the Q-factor is too high, frequency tuning and the approximate matching between driving and sensing comb structure become difficult, and if the Q-factor is too low, its sensitivity decreases. The optimum Q-factor of our gyro chip design is 4000 range. To get this range, we measured the drive mode Q-factor as vacuum level of our gyro chip and we found that the vacuum level of the desired Q-factor 4000 is in the range of 740 mTorr. Based on this data, we fabricate the wafer level package gyro chip of the desired Q-factor by controlled the basic pressure of package bonding chamber just prior to the bonding process. After wafer level package process, we measured Q-factor of whole samples. Among 804 samples, 502 packaged gyro chips are worked and the Q-factor of 67{\%} samples is between 3500 and 4500 range.",
author = "Kim, {Jong Seok} and Lee, {Sang Woo} and Jung, {Kyu Dong} and Kim, {Woon Bae} and Choa, {Sung Hoon} and Ju, {Byeong Kwon}",
year = "2008",
month = "6",
day = "1",
doi = "10.1016/j.microrel.2008.03.001",
language = "English",
volume = "48",
pages = "948--952",
journal = "Microelectronics and Reliability",
issn = "0026-2714",
publisher = "Elsevier Limited",
number = "6",

}

TY - JOUR

T1 - Quality factor measurement of micro gyroscope structure according to vacuum level and desired Q-factor range package method

AU - Kim, Jong Seok

AU - Lee, Sang Woo

AU - Jung, Kyu Dong

AU - Kim, Woon Bae

AU - Choa, Sung Hoon

AU - Ju, Byeong Kwon

PY - 2008/6/1

Y1 - 2008/6/1

N2 - A micro-machined gyro chip of gyroscope is normally packaged in specific vacuum level to get the specific quality factor(Q-factor). If the Q-factor is too high, frequency tuning and the approximate matching between driving and sensing comb structure become difficult, and if the Q-factor is too low, its sensitivity decreases. The optimum Q-factor of our gyro chip design is 4000 range. To get this range, we measured the drive mode Q-factor as vacuum level of our gyro chip and we found that the vacuum level of the desired Q-factor 4000 is in the range of 740 mTorr. Based on this data, we fabricate the wafer level package gyro chip of the desired Q-factor by controlled the basic pressure of package bonding chamber just prior to the bonding process. After wafer level package process, we measured Q-factor of whole samples. Among 804 samples, 502 packaged gyro chips are worked and the Q-factor of 67% samples is between 3500 and 4500 range.

AB - A micro-machined gyro chip of gyroscope is normally packaged in specific vacuum level to get the specific quality factor(Q-factor). If the Q-factor is too high, frequency tuning and the approximate matching between driving and sensing comb structure become difficult, and if the Q-factor is too low, its sensitivity decreases. The optimum Q-factor of our gyro chip design is 4000 range. To get this range, we measured the drive mode Q-factor as vacuum level of our gyro chip and we found that the vacuum level of the desired Q-factor 4000 is in the range of 740 mTorr. Based on this data, we fabricate the wafer level package gyro chip of the desired Q-factor by controlled the basic pressure of package bonding chamber just prior to the bonding process. After wafer level package process, we measured Q-factor of whole samples. Among 804 samples, 502 packaged gyro chips are worked and the Q-factor of 67% samples is between 3500 and 4500 range.

UR - http://www.scopus.com/inward/record.url?scp=45849146963&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=45849146963&partnerID=8YFLogxK

U2 - 10.1016/j.microrel.2008.03.001

DO - 10.1016/j.microrel.2008.03.001

M3 - Article

AN - SCOPUS:45849146963

VL - 48

SP - 948

EP - 952

JO - Microelectronics and Reliability

JF - Microelectronics and Reliability

SN - 0026-2714

IS - 6

ER -