Recent progress of non-invasive optical modality to brain computer interface: A review study

Jae Ho Han, Seungbae Ji, Chang Shi, Seung Beom Yu, Jaeyoung Shin

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

Brain activity is usually measured by non-invasive modalities. Inter alia, the electroencephalogram (EEG) is used most commonly. However, EEG is very sensitive to other biosignals, so other bio-signal detection modalities must be used as supplementary systems. Functional near-infrared spectroscopy (fNIRS) has good characteristics for use as such a supplementary modality, because brain activities can be measured by fNIRS through hemodynamic responses. Therefore, many scientists have adopted fNIRS for brain machine interface (BCI). Recently, fNIRS has become more compact and is robust to noise, so it could bring us to the development of an effective wearable BCI.

Original languageEnglish
Title of host publication3rd International Winter Conference on Brain-Computer Interface, BCI 2015
PublisherInstitute of Electrical and Electronics Engineers Inc.
ISBN (Print)9781479974948
DOIs
Publication statusPublished - 2015 Mar 30
Event2015 3rd International Winter Conference on Brain-Computer Interface, BCI 2015 - Gangwon-Do, Korea, Republic of
Duration: 2015 Jan 122015 Jan 14

Other

Other2015 3rd International Winter Conference on Brain-Computer Interface, BCI 2015
CountryKorea, Republic of
CityGangwon-Do
Period15/1/1215/1/14

Fingerprint

Brain-Computer Interfaces
Brain computer interface
Near infrared spectroscopy
Near-Infrared Spectroscopy
Brain
Electroencephalography
Signal detection
Hemodynamics
Noise

Keywords

  • biomedical optical imaging
  • brain-computer interface
  • optical signal detection
  • spectroscopy

ASJC Scopus subject areas

  • Human-Computer Interaction
  • Cognitive Neuroscience
  • Sensory Systems

Cite this

Han, J. H., Ji, S., Shi, C., Yu, S. B., & Shin, J. (2015). Recent progress of non-invasive optical modality to brain computer interface: A review study. In 3rd International Winter Conference on Brain-Computer Interface, BCI 2015 [7073037] Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/IWW-BCI.2015.7073037

Recent progress of non-invasive optical modality to brain computer interface : A review study. / Han, Jae Ho; Ji, Seungbae; Shi, Chang; Yu, Seung Beom; Shin, Jaeyoung.

3rd International Winter Conference on Brain-Computer Interface, BCI 2015. Institute of Electrical and Electronics Engineers Inc., 2015. 7073037.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Han, JH, Ji, S, Shi, C, Yu, SB & Shin, J 2015, Recent progress of non-invasive optical modality to brain computer interface: A review study. in 3rd International Winter Conference on Brain-Computer Interface, BCI 2015., 7073037, Institute of Electrical and Electronics Engineers Inc., 2015 3rd International Winter Conference on Brain-Computer Interface, BCI 2015, Gangwon-Do, Korea, Republic of, 15/1/12. https://doi.org/10.1109/IWW-BCI.2015.7073037
Han JH, Ji S, Shi C, Yu SB, Shin J. Recent progress of non-invasive optical modality to brain computer interface: A review study. In 3rd International Winter Conference on Brain-Computer Interface, BCI 2015. Institute of Electrical and Electronics Engineers Inc. 2015. 7073037 https://doi.org/10.1109/IWW-BCI.2015.7073037
Han, Jae Ho ; Ji, Seungbae ; Shi, Chang ; Yu, Seung Beom ; Shin, Jaeyoung. / Recent progress of non-invasive optical modality to brain computer interface : A review study. 3rd International Winter Conference on Brain-Computer Interface, BCI 2015. Institute of Electrical and Electronics Engineers Inc., 2015.
@inproceedings{8d6cb0b8d498437da105f010e087aa23,
title = "Recent progress of non-invasive optical modality to brain computer interface: A review study",
abstract = "Brain activity is usually measured by non-invasive modalities. Inter alia, the electroencephalogram (EEG) is used most commonly. However, EEG is very sensitive to other biosignals, so other bio-signal detection modalities must be used as supplementary systems. Functional near-infrared spectroscopy (fNIRS) has good characteristics for use as such a supplementary modality, because brain activities can be measured by fNIRS through hemodynamic responses. Therefore, many scientists have adopted fNIRS for brain machine interface (BCI). Recently, fNIRS has become more compact and is robust to noise, so it could bring us to the development of an effective wearable BCI.",
keywords = "biomedical optical imaging, brain-computer interface, optical signal detection, spectroscopy",
author = "Han, {Jae Ho} and Seungbae Ji and Chang Shi and Yu, {Seung Beom} and Jaeyoung Shin",
year = "2015",
month = "3",
day = "30",
doi = "10.1109/IWW-BCI.2015.7073037",
language = "English",
isbn = "9781479974948",
booktitle = "3rd International Winter Conference on Brain-Computer Interface, BCI 2015",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - Recent progress of non-invasive optical modality to brain computer interface

T2 - A review study

AU - Han, Jae Ho

AU - Ji, Seungbae

AU - Shi, Chang

AU - Yu, Seung Beom

AU - Shin, Jaeyoung

PY - 2015/3/30

Y1 - 2015/3/30

N2 - Brain activity is usually measured by non-invasive modalities. Inter alia, the electroencephalogram (EEG) is used most commonly. However, EEG is very sensitive to other biosignals, so other bio-signal detection modalities must be used as supplementary systems. Functional near-infrared spectroscopy (fNIRS) has good characteristics for use as such a supplementary modality, because brain activities can be measured by fNIRS through hemodynamic responses. Therefore, many scientists have adopted fNIRS for brain machine interface (BCI). Recently, fNIRS has become more compact and is robust to noise, so it could bring us to the development of an effective wearable BCI.

AB - Brain activity is usually measured by non-invasive modalities. Inter alia, the electroencephalogram (EEG) is used most commonly. However, EEG is very sensitive to other biosignals, so other bio-signal detection modalities must be used as supplementary systems. Functional near-infrared spectroscopy (fNIRS) has good characteristics for use as such a supplementary modality, because brain activities can be measured by fNIRS through hemodynamic responses. Therefore, many scientists have adopted fNIRS for brain machine interface (BCI). Recently, fNIRS has become more compact and is robust to noise, so it could bring us to the development of an effective wearable BCI.

KW - biomedical optical imaging

KW - brain-computer interface

KW - optical signal detection

KW - spectroscopy

UR - http://www.scopus.com/inward/record.url?scp=84927931367&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84927931367&partnerID=8YFLogxK

U2 - 10.1109/IWW-BCI.2015.7073037

DO - 10.1109/IWW-BCI.2015.7073037

M3 - Conference contribution

AN - SCOPUS:84927931367

SN - 9781479974948

BT - 3rd International Winter Conference on Brain-Computer Interface, BCI 2015

PB - Institute of Electrical and Electronics Engineers Inc.

ER -