Refrigerant flow through flexible short-tube orifices

Yong Chan Kim, Dennis L. O'Neal, W. Vance Payne, Mohsen Farzad

Research output: Contribution to journalArticle

15 Citations (Scopus)

Abstract

Flexible short-tube orifices were designed to decrease their diameter as the pressure differential across them increases under high outdoor temperatures. A series of tests for an R-22/lubricant mixture (mass fraction of oil 1.2%) were performed with two flexible short-tube orifices to develop flow data over a range of typical air conditioner operating conditions. One short tube had a modulus of elasticity of 7063 kPa and the other a value of 9860 kPa. Both short tubes had identical lengths (14.5 mm), entrance diameters (2.06 mm), and exit diameters (2.46 mm). The tests included both single- and two-phase flow conditions at the inlet of the flexible short tube. Upstream pressures were varied from 1179 kPa to 2144 kPa, which corresponded to saturated condensing temperatures of 29.4 to 54.4°C. Experimental results were presented as a function of pressure, subcooling/quality, evaporating pressure, and modulus of elasticity. Mass flow rates were compared with those of a rigid short tube. The flow rate through the flexible short-tube orifices was strongly dependent on the condensing pressure, subcooling/quality, and modulus of elasticity (which, in effect, changed diameter at different upstream pressures) of the short-tube material. However, the flow rate showed little dependence on the evaporating pressure. An empirical flow model was developed using the experimental data. This flow model was then combined with an air-conditioning system simulation model. Results from the model indicated that the flexible short tube provided approximately 2 to 3% higher capacity than the fixed expansion devices at temperatures lower than 25°C and higher than 45°C. However, the flow control with the flexible short-tube orifice was not as good as with a thermal expansion valve.

Original languageEnglish
Pages (from-to)179-190
Number of pages12
JournalHVAC and R Research
Volume8
Issue number2
Publication statusPublished - 2002 Apr 1

Fingerprint

refrigerants
orifices
Orifices
Flow of fluids
tubes
Elastic moduli
Flow rate
modulus of elasticity
condensing
upstream
flow velocity
Flow control
Air conditioning
single-phase flow
Two phase flow
Temperature
Thermal expansion
Lubricants
air conditioning
differential pressure

ASJC Scopus subject areas

  • Fluid Flow and Transfer Processes
  • Physical and Theoretical Chemistry
  • Mechanical Engineering
  • Building and Construction

Cite this

Kim, Y. C., O'Neal, D. L., Payne, W. V., & Farzad, M. (2002). Refrigerant flow through flexible short-tube orifices. HVAC and R Research, 8(2), 179-190.

Refrigerant flow through flexible short-tube orifices. / Kim, Yong Chan; O'Neal, Dennis L.; Payne, W. Vance; Farzad, Mohsen.

In: HVAC and R Research, Vol. 8, No. 2, 01.04.2002, p. 179-190.

Research output: Contribution to journalArticle

Kim, YC, O'Neal, DL, Payne, WV & Farzad, M 2002, 'Refrigerant flow through flexible short-tube orifices', HVAC and R Research, vol. 8, no. 2, pp. 179-190.
Kim YC, O'Neal DL, Payne WV, Farzad M. Refrigerant flow through flexible short-tube orifices. HVAC and R Research. 2002 Apr 1;8(2):179-190.
Kim, Yong Chan ; O'Neal, Dennis L. ; Payne, W. Vance ; Farzad, Mohsen. / Refrigerant flow through flexible short-tube orifices. In: HVAC and R Research. 2002 ; Vol. 8, No. 2. pp. 179-190.
@article{fe21a698fb1748d39c75e7b854150fd2,
title = "Refrigerant flow through flexible short-tube orifices",
abstract = "Flexible short-tube orifices were designed to decrease their diameter as the pressure differential across them increases under high outdoor temperatures. A series of tests for an R-22/lubricant mixture (mass fraction of oil 1.2{\%}) were performed with two flexible short-tube orifices to develop flow data over a range of typical air conditioner operating conditions. One short tube had a modulus of elasticity of 7063 kPa and the other a value of 9860 kPa. Both short tubes had identical lengths (14.5 mm), entrance diameters (2.06 mm), and exit diameters (2.46 mm). The tests included both single- and two-phase flow conditions at the inlet of the flexible short tube. Upstream pressures were varied from 1179 kPa to 2144 kPa, which corresponded to saturated condensing temperatures of 29.4 to 54.4°C. Experimental results were presented as a function of pressure, subcooling/quality, evaporating pressure, and modulus of elasticity. Mass flow rates were compared with those of a rigid short tube. The flow rate through the flexible short-tube orifices was strongly dependent on the condensing pressure, subcooling/quality, and modulus of elasticity (which, in effect, changed diameter at different upstream pressures) of the short-tube material. However, the flow rate showed little dependence on the evaporating pressure. An empirical flow model was developed using the experimental data. This flow model was then combined with an air-conditioning system simulation model. Results from the model indicated that the flexible short tube provided approximately 2 to 3{\%} higher capacity than the fixed expansion devices at temperatures lower than 25°C and higher than 45°C. However, the flow control with the flexible short-tube orifice was not as good as with a thermal expansion valve.",
author = "Kim, {Yong Chan} and O'Neal, {Dennis L.} and Payne, {W. Vance} and Mohsen Farzad",
year = "2002",
month = "4",
day = "1",
language = "English",
volume = "8",
pages = "179--190",
journal = "Science and Technology for the Built Environment",
issn = "2374-4731",
publisher = "Taylor and Francis Ltd.",
number = "2",

}

TY - JOUR

T1 - Refrigerant flow through flexible short-tube orifices

AU - Kim, Yong Chan

AU - O'Neal, Dennis L.

AU - Payne, W. Vance

AU - Farzad, Mohsen

PY - 2002/4/1

Y1 - 2002/4/1

N2 - Flexible short-tube orifices were designed to decrease their diameter as the pressure differential across them increases under high outdoor temperatures. A series of tests for an R-22/lubricant mixture (mass fraction of oil 1.2%) were performed with two flexible short-tube orifices to develop flow data over a range of typical air conditioner operating conditions. One short tube had a modulus of elasticity of 7063 kPa and the other a value of 9860 kPa. Both short tubes had identical lengths (14.5 mm), entrance diameters (2.06 mm), and exit diameters (2.46 mm). The tests included both single- and two-phase flow conditions at the inlet of the flexible short tube. Upstream pressures were varied from 1179 kPa to 2144 kPa, which corresponded to saturated condensing temperatures of 29.4 to 54.4°C. Experimental results were presented as a function of pressure, subcooling/quality, evaporating pressure, and modulus of elasticity. Mass flow rates were compared with those of a rigid short tube. The flow rate through the flexible short-tube orifices was strongly dependent on the condensing pressure, subcooling/quality, and modulus of elasticity (which, in effect, changed diameter at different upstream pressures) of the short-tube material. However, the flow rate showed little dependence on the evaporating pressure. An empirical flow model was developed using the experimental data. This flow model was then combined with an air-conditioning system simulation model. Results from the model indicated that the flexible short tube provided approximately 2 to 3% higher capacity than the fixed expansion devices at temperatures lower than 25°C and higher than 45°C. However, the flow control with the flexible short-tube orifice was not as good as with a thermal expansion valve.

AB - Flexible short-tube orifices were designed to decrease their diameter as the pressure differential across them increases under high outdoor temperatures. A series of tests for an R-22/lubricant mixture (mass fraction of oil 1.2%) were performed with two flexible short-tube orifices to develop flow data over a range of typical air conditioner operating conditions. One short tube had a modulus of elasticity of 7063 kPa and the other a value of 9860 kPa. Both short tubes had identical lengths (14.5 mm), entrance diameters (2.06 mm), and exit diameters (2.46 mm). The tests included both single- and two-phase flow conditions at the inlet of the flexible short tube. Upstream pressures were varied from 1179 kPa to 2144 kPa, which corresponded to saturated condensing temperatures of 29.4 to 54.4°C. Experimental results were presented as a function of pressure, subcooling/quality, evaporating pressure, and modulus of elasticity. Mass flow rates were compared with those of a rigid short tube. The flow rate through the flexible short-tube orifices was strongly dependent on the condensing pressure, subcooling/quality, and modulus of elasticity (which, in effect, changed diameter at different upstream pressures) of the short-tube material. However, the flow rate showed little dependence on the evaporating pressure. An empirical flow model was developed using the experimental data. This flow model was then combined with an air-conditioning system simulation model. Results from the model indicated that the flexible short tube provided approximately 2 to 3% higher capacity than the fixed expansion devices at temperatures lower than 25°C and higher than 45°C. However, the flow control with the flexible short-tube orifice was not as good as with a thermal expansion valve.

UR - http://www.scopus.com/inward/record.url?scp=0036543572&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036543572&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0036543572

VL - 8

SP - 179

EP - 190

JO - Science and Technology for the Built Environment

JF - Science and Technology for the Built Environment

SN - 2374-4731

IS - 2

ER -