Single red blood cell deformability test using optical trapping in plastic microfluidic chip

W. G. Lee, J. Park, H. Bang, Seok Chung, K. Cho, C. Chung, D. C. Han, J. K. Chang

Research output: Chapter in Book/Report/Conference proceedingConference contribution

7 Citations (Scopus)

Abstract

In this study, single red blood cell (RBC) deformability test is performed by using optical trapping in poly(dimethylsiloxane) PDMS microfludic chip. The salient feature of this method is to provide more extensional recovery time of individual RBCs in order to tell the minor difference of RBC deformability between normal and abnormal blood.

Original languageEnglish
Title of host publication2005 3rd IEEE/EMBS Special Topic Conference on Microtechnology in Medicine and Biology
Pages389-390
Number of pages2
Volume2005
DOIs
Publication statusPublished - 2005 Dec 1
Externally publishedYes
Event2005 3rd IEEE/EMBS Special Topic Conference on Microtechnology in Medicine and Biology - Oahu, HI, United States
Duration: 2005 May 122005 May 15

Other

Other2005 3rd IEEE/EMBS Special Topic Conference on Microtechnology in Medicine and Biology
CountryUnited States
CityOahu, HI
Period05/5/1205/5/15

Fingerprint

Formability
Microfluidics
Blood
Cells
Plastics
Polydimethylsiloxane
Recovery

Keywords

  • Deformability
  • Optical trapping
  • RBC

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Lee, W. G., Park, J., Bang, H., Chung, S., Cho, K., Chung, C., ... Chang, J. K. (2005). Single red blood cell deformability test using optical trapping in plastic microfluidic chip. In 2005 3rd IEEE/EMBS Special Topic Conference on Microtechnology in Medicine and Biology (Vol. 2005, pp. 389-390). [1548483] https://doi.org/10.1109/MMB.2005.1548483

Single red blood cell deformability test using optical trapping in plastic microfluidic chip. / Lee, W. G.; Park, J.; Bang, H.; Chung, Seok; Cho, K.; Chung, C.; Han, D. C.; Chang, J. K.

2005 3rd IEEE/EMBS Special Topic Conference on Microtechnology in Medicine and Biology. Vol. 2005 2005. p. 389-390 1548483.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Lee, WG, Park, J, Bang, H, Chung, S, Cho, K, Chung, C, Han, DC & Chang, JK 2005, Single red blood cell deformability test using optical trapping in plastic microfluidic chip. in 2005 3rd IEEE/EMBS Special Topic Conference on Microtechnology in Medicine and Biology. vol. 2005, 1548483, pp. 389-390, 2005 3rd IEEE/EMBS Special Topic Conference on Microtechnology in Medicine and Biology, Oahu, HI, United States, 05/5/12. https://doi.org/10.1109/MMB.2005.1548483
Lee WG, Park J, Bang H, Chung S, Cho K, Chung C et al. Single red blood cell deformability test using optical trapping in plastic microfluidic chip. In 2005 3rd IEEE/EMBS Special Topic Conference on Microtechnology in Medicine and Biology. Vol. 2005. 2005. p. 389-390. 1548483 https://doi.org/10.1109/MMB.2005.1548483
Lee, W. G. ; Park, J. ; Bang, H. ; Chung, Seok ; Cho, K. ; Chung, C. ; Han, D. C. ; Chang, J. K. / Single red blood cell deformability test using optical trapping in plastic microfluidic chip. 2005 3rd IEEE/EMBS Special Topic Conference on Microtechnology in Medicine and Biology. Vol. 2005 2005. pp. 389-390
@inproceedings{4b50e55369754eacb8686b13ce4f1899,
title = "Single red blood cell deformability test using optical trapping in plastic microfluidic chip",
abstract = "In this study, single red blood cell (RBC) deformability test is performed by using optical trapping in poly(dimethylsiloxane) PDMS microfludic chip. The salient feature of this method is to provide more extensional recovery time of individual RBCs in order to tell the minor difference of RBC deformability between normal and abnormal blood.",
keywords = "Deformability, Optical trapping, RBC",
author = "Lee, {W. G.} and J. Park and H. Bang and Seok Chung and K. Cho and C. Chung and Han, {D. C.} and Chang, {J. K.}",
year = "2005",
month = "12",
day = "1",
doi = "10.1109/MMB.2005.1548483",
language = "English",
isbn = "0780387112",
volume = "2005",
pages = "389--390",
booktitle = "2005 3rd IEEE/EMBS Special Topic Conference on Microtechnology in Medicine and Biology",

}

TY - GEN

T1 - Single red blood cell deformability test using optical trapping in plastic microfluidic chip

AU - Lee, W. G.

AU - Park, J.

AU - Bang, H.

AU - Chung, Seok

AU - Cho, K.

AU - Chung, C.

AU - Han, D. C.

AU - Chang, J. K.

PY - 2005/12/1

Y1 - 2005/12/1

N2 - In this study, single red blood cell (RBC) deformability test is performed by using optical trapping in poly(dimethylsiloxane) PDMS microfludic chip. The salient feature of this method is to provide more extensional recovery time of individual RBCs in order to tell the minor difference of RBC deformability between normal and abnormal blood.

AB - In this study, single red blood cell (RBC) deformability test is performed by using optical trapping in poly(dimethylsiloxane) PDMS microfludic chip. The salient feature of this method is to provide more extensional recovery time of individual RBCs in order to tell the minor difference of RBC deformability between normal and abnormal blood.

KW - Deformability

KW - Optical trapping

KW - RBC

UR - http://www.scopus.com/inward/record.url?scp=33646186507&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33646186507&partnerID=8YFLogxK

U2 - 10.1109/MMB.2005.1548483

DO - 10.1109/MMB.2005.1548483

M3 - Conference contribution

AN - SCOPUS:33646186507

SN - 0780387112

SN - 9780780387119

VL - 2005

SP - 389

EP - 390

BT - 2005 3rd IEEE/EMBS Special Topic Conference on Microtechnology in Medicine and Biology

ER -