Speed-up of the auto-titrator operation

Tae Heon Lee, Jietae Lee, Seungjae Lee, Dae Ryook Yang

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

The acid-base titration is used wide in the fields of chemical engineering, environmental engineering, agriculture, and medical science. The auto-titrator is a commercial apparatus that carries out the titration operation automatically and provides the equivalence point data. For some test samples and operating conditions, titration operations require up to around 5 minutes. Here we propose a method to reduce this operation time by one-fifth. For this, systems technologies such as reducing sensor time-constant with a lead-lag filter, parameter identification and alternative dosing of titrating and sample solutions have been applied. Test equipment that simulates commercial auto-titrators is introduced.

Original languageEnglish
Title of host publication2008 International Conference on Control, Automation and Systems, ICCAS 2008
Pages2872-2875
Number of pages4
DOIs
Publication statusPublished - 2008 Dec 1
Event2008 International Conference on Control, Automation and Systems, ICCAS 2008 - Seoul, Korea, Republic of
Duration: 2008 Oct 142008 Oct 17

Other

Other2008 International Conference on Control, Automation and Systems, ICCAS 2008
CountryKorea, Republic of
CitySeoul
Period08/10/1408/10/17

Fingerprint

Titration
Environmental engineering
Chemical engineering
Agriculture
Identification (control systems)
Lead
Acids
Sensors

Keywords

  • Auto-titrator
  • Equivalent point
  • pH
  • Titration curve

ASJC Scopus subject areas

  • Control and Systems Engineering

Cite this

Lee, T. H., Lee, J., Lee, S., & Yang, D. R. (2008). Speed-up of the auto-titrator operation. In 2008 International Conference on Control, Automation and Systems, ICCAS 2008 (pp. 2872-2875). [4694247] https://doi.org/10.1109/ICCAS.2008.4694247

Speed-up of the auto-titrator operation. / Lee, Tae Heon; Lee, Jietae; Lee, Seungjae; Yang, Dae Ryook.

2008 International Conference on Control, Automation and Systems, ICCAS 2008. 2008. p. 2872-2875 4694247.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Lee, TH, Lee, J, Lee, S & Yang, DR 2008, Speed-up of the auto-titrator operation. in 2008 International Conference on Control, Automation and Systems, ICCAS 2008., 4694247, pp. 2872-2875, 2008 International Conference on Control, Automation and Systems, ICCAS 2008, Seoul, Korea, Republic of, 08/10/14. https://doi.org/10.1109/ICCAS.2008.4694247
Lee TH, Lee J, Lee S, Yang DR. Speed-up of the auto-titrator operation. In 2008 International Conference on Control, Automation and Systems, ICCAS 2008. 2008. p. 2872-2875. 4694247 https://doi.org/10.1109/ICCAS.2008.4694247
Lee, Tae Heon ; Lee, Jietae ; Lee, Seungjae ; Yang, Dae Ryook. / Speed-up of the auto-titrator operation. 2008 International Conference on Control, Automation and Systems, ICCAS 2008. 2008. pp. 2872-2875
@inproceedings{598b1d6bde7948aeb1aec1b3569b099a,
title = "Speed-up of the auto-titrator operation",
abstract = "The acid-base titration is used wide in the fields of chemical engineering, environmental engineering, agriculture, and medical science. The auto-titrator is a commercial apparatus that carries out the titration operation automatically and provides the equivalence point data. For some test samples and operating conditions, titration operations require up to around 5 minutes. Here we propose a method to reduce this operation time by one-fifth. For this, systems technologies such as reducing sensor time-constant with a lead-lag filter, parameter identification and alternative dosing of titrating and sample solutions have been applied. Test equipment that simulates commercial auto-titrators is introduced.",
keywords = "Auto-titrator, Equivalent point, pH, Titration curve",
author = "Lee, {Tae Heon} and Jietae Lee and Seungjae Lee and Yang, {Dae Ryook}",
year = "2008",
month = "12",
day = "1",
doi = "10.1109/ICCAS.2008.4694247",
language = "English",
isbn = "9788995003893",
pages = "2872--2875",
booktitle = "2008 International Conference on Control, Automation and Systems, ICCAS 2008",

}

TY - GEN

T1 - Speed-up of the auto-titrator operation

AU - Lee, Tae Heon

AU - Lee, Jietae

AU - Lee, Seungjae

AU - Yang, Dae Ryook

PY - 2008/12/1

Y1 - 2008/12/1

N2 - The acid-base titration is used wide in the fields of chemical engineering, environmental engineering, agriculture, and medical science. The auto-titrator is a commercial apparatus that carries out the titration operation automatically and provides the equivalence point data. For some test samples and operating conditions, titration operations require up to around 5 minutes. Here we propose a method to reduce this operation time by one-fifth. For this, systems technologies such as reducing sensor time-constant with a lead-lag filter, parameter identification and alternative dosing of titrating and sample solutions have been applied. Test equipment that simulates commercial auto-titrators is introduced.

AB - The acid-base titration is used wide in the fields of chemical engineering, environmental engineering, agriculture, and medical science. The auto-titrator is a commercial apparatus that carries out the titration operation automatically and provides the equivalence point data. For some test samples and operating conditions, titration operations require up to around 5 minutes. Here we propose a method to reduce this operation time by one-fifth. For this, systems technologies such as reducing sensor time-constant with a lead-lag filter, parameter identification and alternative dosing of titrating and sample solutions have been applied. Test equipment that simulates commercial auto-titrators is introduced.

KW - Auto-titrator

KW - Equivalent point

KW - pH

KW - Titration curve

UR - http://www.scopus.com/inward/record.url?scp=58149092630&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=58149092630&partnerID=8YFLogxK

U2 - 10.1109/ICCAS.2008.4694247

DO - 10.1109/ICCAS.2008.4694247

M3 - Conference contribution

SN - 9788995003893

SP - 2872

EP - 2875

BT - 2008 International Conference on Control, Automation and Systems, ICCAS 2008

ER -