Staged voltage mode in membrane capacitive deionization: Comparison with constant voltage and constant current modes

Jongmoon Choi, Jungwon Kim, Seungkwan Hong

Research output: Contribution to journalArticle

Abstract

The most typical membrane capacitive deionization (MCDI) operating modes, constant voltage (CV) and constant current (CC), respectively, exhibit their own limitations on energy consumption and removal efficiency. Therefore, a staged voltage (SV) mode was first investigated as a method to take advantage of the CV and CC modes. To verify the feasibility of the SV mode, a two-staged voltage mode (2SV) was primarily operated by ascending and descending the applied voltage under various TDS concentrations of the feed solution. Then, the removal efficiency and energy consumption of the 2SV, linearly (LSV) and exponentially staged voltage (ESV) modes, were systematically estimated. From our experimental results, the applied voltage at the stage as well as the voltage difference was identified to be critical factors for both the removal and energy issues. Although the CC mode was determined to be the most energy efficient, limited removal efficiency could be the dilemma, and thus, our proposed SV mode is believed to be the most adequate strategy for MCDI operation for meeting the required water quality with lowest energy consummation.

Original languageEnglish
Article number114327
JournalDesalination
Volume479
DOIs
Publication statusPublished - 2020 Apr 1

Keywords

  • Capacitive deionization (CDI)
  • Constant current (CC)
  • Constant voltage (CV)
  • Energy efficiency
  • Staged voltage (SV)

ASJC Scopus subject areas

  • Chemistry(all)
  • Chemical Engineering(all)
  • Materials Science(all)
  • Water Science and Technology
  • Mechanical Engineering

Cite this

Staged voltage mode in membrane capacitive deionization : Comparison with constant voltage and constant current modes. / Choi, Jongmoon; Kim, Jungwon; Hong, Seungkwan.

In: Desalination, Vol. 479, 114327, 01.04.2020.

Research output: Contribution to journalArticle

@article{68b5c6943e774a168a52efd8b832c9c9,
title = "Staged voltage mode in membrane capacitive deionization: Comparison with constant voltage and constant current modes",
abstract = "The most typical membrane capacitive deionization (MCDI) operating modes, constant voltage (CV) and constant current (CC), respectively, exhibit their own limitations on energy consumption and removal efficiency. Therefore, a staged voltage (SV) mode was first investigated as a method to take advantage of the CV and CC modes. To verify the feasibility of the SV mode, a two-staged voltage mode (2SV) was primarily operated by ascending and descending the applied voltage under various TDS concentrations of the feed solution. Then, the removal efficiency and energy consumption of the 2SV, linearly (LSV) and exponentially staged voltage (ESV) modes, were systematically estimated. From our experimental results, the applied voltage at the stage as well as the voltage difference was identified to be critical factors for both the removal and energy issues. Although the CC mode was determined to be the most energy efficient, limited removal efficiency could be the dilemma, and thus, our proposed SV mode is believed to be the most adequate strategy for MCDI operation for meeting the required water quality with lowest energy consummation.",
keywords = "Capacitive deionization (CDI), Constant current (CC), Constant voltage (CV), Energy efficiency, Staged voltage (SV)",
author = "Jongmoon Choi and Jungwon Kim and Seungkwan Hong",
year = "2020",
month = "4",
day = "1",
doi = "10.1016/j.desal.2020.114327",
language = "English",
volume = "479",
journal = "Desalination",
issn = "0011-9164",
publisher = "Elsevier",

}

TY - JOUR

T1 - Staged voltage mode in membrane capacitive deionization

T2 - Comparison with constant voltage and constant current modes

AU - Choi, Jongmoon

AU - Kim, Jungwon

AU - Hong, Seungkwan

PY - 2020/4/1

Y1 - 2020/4/1

N2 - The most typical membrane capacitive deionization (MCDI) operating modes, constant voltage (CV) and constant current (CC), respectively, exhibit their own limitations on energy consumption and removal efficiency. Therefore, a staged voltage (SV) mode was first investigated as a method to take advantage of the CV and CC modes. To verify the feasibility of the SV mode, a two-staged voltage mode (2SV) was primarily operated by ascending and descending the applied voltage under various TDS concentrations of the feed solution. Then, the removal efficiency and energy consumption of the 2SV, linearly (LSV) and exponentially staged voltage (ESV) modes, were systematically estimated. From our experimental results, the applied voltage at the stage as well as the voltage difference was identified to be critical factors for both the removal and energy issues. Although the CC mode was determined to be the most energy efficient, limited removal efficiency could be the dilemma, and thus, our proposed SV mode is believed to be the most adequate strategy for MCDI operation for meeting the required water quality with lowest energy consummation.

AB - The most typical membrane capacitive deionization (MCDI) operating modes, constant voltage (CV) and constant current (CC), respectively, exhibit their own limitations on energy consumption and removal efficiency. Therefore, a staged voltage (SV) mode was first investigated as a method to take advantage of the CV and CC modes. To verify the feasibility of the SV mode, a two-staged voltage mode (2SV) was primarily operated by ascending and descending the applied voltage under various TDS concentrations of the feed solution. Then, the removal efficiency and energy consumption of the 2SV, linearly (LSV) and exponentially staged voltage (ESV) modes, were systematically estimated. From our experimental results, the applied voltage at the stage as well as the voltage difference was identified to be critical factors for both the removal and energy issues. Although the CC mode was determined to be the most energy efficient, limited removal efficiency could be the dilemma, and thus, our proposed SV mode is believed to be the most adequate strategy for MCDI operation for meeting the required water quality with lowest energy consummation.

KW - Capacitive deionization (CDI)

KW - Constant current (CC)

KW - Constant voltage (CV)

KW - Energy efficiency

KW - Staged voltage (SV)

UR - http://www.scopus.com/inward/record.url?scp=85077918620&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85077918620&partnerID=8YFLogxK

U2 - 10.1016/j.desal.2020.114327

DO - 10.1016/j.desal.2020.114327

M3 - Article

AN - SCOPUS:85077918620

VL - 479

JO - Desalination

JF - Desalination

SN - 0011-9164

M1 - 114327