Sterilization of Escherichia coli O157: H7 using micro corona ionizer

Beelee Chua, Ahjeong Son

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

We demonstrated in vitro sterilization of Escherichia coli O157:H7 bacteria on agar by a pin-between-planes micro corona ionizer. The gap between the pin and the grid was ∼1.1 mm, the length of the grid was ∼2.1mmand the height was ∼1.0mm. The effective pin radius and discharge length were both approximated to be 200 μm. Ozone generation rates of ∼2.3×10 -3 mg/s, ∼2.7×10-3 mg/s and ∼3. 5×10-3 mg/s at 1,500 V were calculated for relative humidity ( RH ) of 35%, 25% and 10% respectively. Analytical ozone generation rate increases as RH decreases and it is consistent with experimental observations. Using target and control petri dishes with E. coli plated agar, the sterilization capability of the micro corona ionizer at 37°C for 24 h was evaluated. A ∼60% reduction in bacterial colony was shown with plate counting and its kill radius could be tuned from∼20mmto ∼5mmby reducing the duty cycle from 100%to 50%with 30min pulse width. The results suggested that the micro corona ionizer might be suitable as a tunable ozone source in wound dressing for chronic wound management.

Original languageEnglish
Pages (from-to)355-363
Number of pages9
JournalBiomedical Microdevices
Volume16
Issue number3
DOIs
Publication statusPublished - 2014 Jan 1

Fingerprint

Escherichia coli O157
Ozone
Escherichia coli
Humidity
Agar
Atmospheric humidity
Wounds and Injuries
Bandages
Bacteria

ASJC Scopus subject areas

  • Biomedical Engineering
  • Molecular Biology

Cite this

Sterilization of Escherichia coli O157 : H7 using micro corona ionizer. / Chua, Beelee; Son, Ahjeong.

In: Biomedical Microdevices, Vol. 16, No. 3, 01.01.2014, p. 355-363.

Research output: Contribution to journalArticle

Chua, Beelee ; Son, Ahjeong. / Sterilization of Escherichia coli O157 : H7 using micro corona ionizer. In: Biomedical Microdevices. 2014 ; Vol. 16, No. 3. pp. 355-363.
@article{33460e1a2c9048bd88c80a92945fcf5a,
title = "Sterilization of Escherichia coli O157: H7 using micro corona ionizer",
abstract = "We demonstrated in vitro sterilization of Escherichia coli O157:H7 bacteria on agar by a pin-between-planes micro corona ionizer. The gap between the pin and the grid was ∼1.1 mm, the length of the grid was ∼2.1mmand the height was ∼1.0mm. The effective pin radius and discharge length were both approximated to be 200 μm. Ozone generation rates of ∼2.3×10 -3 mg/s, ∼2.7×10-3 mg/s and ∼3. 5×10-3 mg/s at 1,500 V were calculated for relative humidity ( RH ) of 35{\%}, 25{\%} and 10{\%} respectively. Analytical ozone generation rate increases as RH decreases and it is consistent with experimental observations. Using target and control petri dishes with E. coli plated agar, the sterilization capability of the micro corona ionizer at 37°C for 24 h was evaluated. A ∼60{\%} reduction in bacterial colony was shown with plate counting and its kill radius could be tuned from∼20mmto ∼5mmby reducing the duty cycle from 100{\%}to 50{\%}with 30min pulse width. The results suggested that the micro corona ionizer might be suitable as a tunable ozone source in wound dressing for chronic wound management.",
keywords = "Chronic wound management, Escherichia coli O157:H7, In vitro, Micro corona ionizer, Ozone, Sterilization",
author = "Beelee Chua and Ahjeong Son",
year = "2014",
month = "1",
day = "1",
doi = "10.1007/s10544-014-9838-4",
language = "English",
volume = "16",
pages = "355--363",
journal = "Biomedical Microdevices",
issn = "1387-2176",
publisher = "Kluwer Academic Publishers",
number = "3",

}

TY - JOUR

T1 - Sterilization of Escherichia coli O157

T2 - H7 using micro corona ionizer

AU - Chua, Beelee

AU - Son, Ahjeong

PY - 2014/1/1

Y1 - 2014/1/1

N2 - We demonstrated in vitro sterilization of Escherichia coli O157:H7 bacteria on agar by a pin-between-planes micro corona ionizer. The gap between the pin and the grid was ∼1.1 mm, the length of the grid was ∼2.1mmand the height was ∼1.0mm. The effective pin radius and discharge length were both approximated to be 200 μm. Ozone generation rates of ∼2.3×10 -3 mg/s, ∼2.7×10-3 mg/s and ∼3. 5×10-3 mg/s at 1,500 V were calculated for relative humidity ( RH ) of 35%, 25% and 10% respectively. Analytical ozone generation rate increases as RH decreases and it is consistent with experimental observations. Using target and control petri dishes with E. coli plated agar, the sterilization capability of the micro corona ionizer at 37°C for 24 h was evaluated. A ∼60% reduction in bacterial colony was shown with plate counting and its kill radius could be tuned from∼20mmto ∼5mmby reducing the duty cycle from 100%to 50%with 30min pulse width. The results suggested that the micro corona ionizer might be suitable as a tunable ozone source in wound dressing for chronic wound management.

AB - We demonstrated in vitro sterilization of Escherichia coli O157:H7 bacteria on agar by a pin-between-planes micro corona ionizer. The gap between the pin and the grid was ∼1.1 mm, the length of the grid was ∼2.1mmand the height was ∼1.0mm. The effective pin radius and discharge length were both approximated to be 200 μm. Ozone generation rates of ∼2.3×10 -3 mg/s, ∼2.7×10-3 mg/s and ∼3. 5×10-3 mg/s at 1,500 V were calculated for relative humidity ( RH ) of 35%, 25% and 10% respectively. Analytical ozone generation rate increases as RH decreases and it is consistent with experimental observations. Using target and control petri dishes with E. coli plated agar, the sterilization capability of the micro corona ionizer at 37°C for 24 h was evaluated. A ∼60% reduction in bacterial colony was shown with plate counting and its kill radius could be tuned from∼20mmto ∼5mmby reducing the duty cycle from 100%to 50%with 30min pulse width. The results suggested that the micro corona ionizer might be suitable as a tunable ozone source in wound dressing for chronic wound management.

KW - Chronic wound management

KW - Escherichia coli O157:H7

KW - In vitro

KW - Micro corona ionizer

KW - Ozone

KW - Sterilization

UR - http://www.scopus.com/inward/record.url?scp=84904182391&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84904182391&partnerID=8YFLogxK

U2 - 10.1007/s10544-014-9838-4

DO - 10.1007/s10544-014-9838-4

M3 - Article

C2 - 24481590

AN - SCOPUS:84904182391

VL - 16

SP - 355

EP - 363

JO - Biomedical Microdevices

JF - Biomedical Microdevices

SN - 1387-2176

IS - 3

ER -