The objective of this study was to investigate the feasibility of replacing a conventional plate fin-tube evaporator with a spiral fin-tube evaporator by comparing the performance of domestic refrigerator-freezers adopting either the plate fin-tube evaporator or spiral fin-tube evaporator. Experiments were conducted for the domestic refrigerator-freezers using either a 2-column and 15-row plate fin-tube evaporator or three spiral fin-tube evaporators with 11, 13, and 15 tube rows (N). The optimum refrigerant charge decreased with a decrease in the number of tube rows. The power consumptions of the domestic refrigerator-freezers using the spiral fin-tube evaporators with N = 11 and 13 were 2.8% and 1.5% lower than those using the plate fin-tube evaporator, respectively. In addition, the cooling capacity of the spiral fin-tube evaporator with N = 13 was 3%-7% higher than that of the plate fin-tube evaporator under the frosting condition. In a cooling speed test, all of the evaporators showed similar performances.

Original languageEnglish
Pages (from-to)205-212
Number of pages8
JournalTransactions of the Korean Society of Mechanical Engineers, B
Volume37
Issue number3
DOIs
Publication statusPublished - 2013 Jan 1

Fingerprint

Refrigerators
Evaporators
Fins (heat exchange)
Cooling
Refrigerants
Electric power utilization

Keywords

  • Domestic Refrigerator-Freezer
  • Evaporator
  • Spiral Fin

ASJC Scopus subject areas

  • Mechanical Engineering

Cite this

Study on performance characteristics of spiral fin-tube evaporator applied to domestic refrigerator-freezers. / Lee, Sang Hun; Yoon, Won Jae; Kim, Yong Chan; Lee, Mooyeon; Yun, Seongjung.

In: Transactions of the Korean Society of Mechanical Engineers, B, Vol. 37, No. 3, 01.01.2013, p. 205-212.

Research output: Contribution to journalArticle

@article{fc5b3f276d714462936ba8ba21a503ba,
title = "Study on performance characteristics of spiral fin-tube evaporator applied to domestic refrigerator-freezers",
abstract = "The objective of this study was to investigate the feasibility of replacing a conventional plate fin-tube evaporator with a spiral fin-tube evaporator by comparing the performance of domestic refrigerator-freezers adopting either the plate fin-tube evaporator or spiral fin-tube evaporator. Experiments were conducted for the domestic refrigerator-freezers using either a 2-column and 15-row plate fin-tube evaporator or three spiral fin-tube evaporators with 11, 13, and 15 tube rows (N). The optimum refrigerant charge decreased with a decrease in the number of tube rows. The power consumptions of the domestic refrigerator-freezers using the spiral fin-tube evaporators with N = 11 and 13 were 2.8{\%} and 1.5{\%} lower than those using the plate fin-tube evaporator, respectively. In addition, the cooling capacity of the spiral fin-tube evaporator with N = 13 was 3{\%}-7{\%} higher than that of the plate fin-tube evaporator under the frosting condition. In a cooling speed test, all of the evaporators showed similar performances.",
keywords = "Domestic Refrigerator-Freezer, Evaporator, Spiral Fin",
author = "Lee, {Sang Hun} and Yoon, {Won Jae} and Kim, {Yong Chan} and Mooyeon Lee and Seongjung Yun",
year = "2013",
month = "1",
day = "1",
doi = "10.3795/KSME-B.2013.37.3.205",
language = "English",
volume = "37",
pages = "205--212",
journal = "Transactions of the Korean Society of Mechanical Engineers, B",
issn = "1226-4881",
publisher = "Korean Society of Mechanical Engineers",
number = "3",

}

TY - JOUR

T1 - Study on performance characteristics of spiral fin-tube evaporator applied to domestic refrigerator-freezers

AU - Lee, Sang Hun

AU - Yoon, Won Jae

AU - Kim, Yong Chan

AU - Lee, Mooyeon

AU - Yun, Seongjung

PY - 2013/1/1

Y1 - 2013/1/1

N2 - The objective of this study was to investigate the feasibility of replacing a conventional plate fin-tube evaporator with a spiral fin-tube evaporator by comparing the performance of domestic refrigerator-freezers adopting either the plate fin-tube evaporator or spiral fin-tube evaporator. Experiments were conducted for the domestic refrigerator-freezers using either a 2-column and 15-row plate fin-tube evaporator or three spiral fin-tube evaporators with 11, 13, and 15 tube rows (N). The optimum refrigerant charge decreased with a decrease in the number of tube rows. The power consumptions of the domestic refrigerator-freezers using the spiral fin-tube evaporators with N = 11 and 13 were 2.8% and 1.5% lower than those using the plate fin-tube evaporator, respectively. In addition, the cooling capacity of the spiral fin-tube evaporator with N = 13 was 3%-7% higher than that of the plate fin-tube evaporator under the frosting condition. In a cooling speed test, all of the evaporators showed similar performances.

AB - The objective of this study was to investigate the feasibility of replacing a conventional plate fin-tube evaporator with a spiral fin-tube evaporator by comparing the performance of domestic refrigerator-freezers adopting either the plate fin-tube evaporator or spiral fin-tube evaporator. Experiments were conducted for the domestic refrigerator-freezers using either a 2-column and 15-row plate fin-tube evaporator or three spiral fin-tube evaporators with 11, 13, and 15 tube rows (N). The optimum refrigerant charge decreased with a decrease in the number of tube rows. The power consumptions of the domestic refrigerator-freezers using the spiral fin-tube evaporators with N = 11 and 13 were 2.8% and 1.5% lower than those using the plate fin-tube evaporator, respectively. In addition, the cooling capacity of the spiral fin-tube evaporator with N = 13 was 3%-7% higher than that of the plate fin-tube evaporator under the frosting condition. In a cooling speed test, all of the evaporators showed similar performances.

KW - Domestic Refrigerator-Freezer

KW - Evaporator

KW - Spiral Fin

UR - http://www.scopus.com/inward/record.url?scp=84898469776&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84898469776&partnerID=8YFLogxK

U2 - 10.3795/KSME-B.2013.37.3.205

DO - 10.3795/KSME-B.2013.37.3.205

M3 - Article

AN - SCOPUS:84898469776

VL - 37

SP - 205

EP - 212

JO - Transactions of the Korean Society of Mechanical Engineers, B

JF - Transactions of the Korean Society of Mechanical Engineers, B

SN - 1226-4881

IS - 3

ER -