SU‐FF‐T‐476: Dose‐Sparing Effects of a Rectal Balloon in Proton Therapy of the Prostate

D. Lee, Myonggeun Yoon, D. Shin, Y. Lim, D. Kim, S. Park, S. Lee, J. Lee, T. Suh

Research output: Contribution to journalArticle

Abstract

Purpose; The normal organ (bladder, rectum) sparing is very important for radiation therapy of the pelivis. Many people are studying with the effort for rectal and bladder spearing, however the actual circumstances to are satisfied which can not find the method. In this study, the decrease used the balloon to order the rectal dose. The aim of the study was to investigate the dose volume effects of a water‐filled rectal balloon in the rectum. Materials and Methods; We inserted the balloon(100cc water filled, 10cm length, 3cm diameter) in rectum for 10 proton therapy patients with prostate cancers. The systems were loaded with Eclipse proton planning system(Ver. 7.5) and Two sets of CT images before and after ballooning were acquired. Rectum and bladder volumes were delineated on 3‐mm‐thick CT images. A comparison between dose volume histogram(DVH) with and without balloon in rectum for proton therapy of the prostate cancers. Results; More organ and target volume changes with shape because inserted the balloon in rectum. Mean dose of rectal difference between with and without balloon was about 20%, because volume of rectum escape from a radiation area due to the balloon. Mean dose of bladder difference between with and without balloon was about 6%. Conclusion; The rectal ballon is very useful for bladder and rectal sparing with proton therapy of the prostate cancers. This research is believed to be sufficiently accurate and clinically useful.

Original languageEnglish
Pages (from-to)2632
Number of pages1
JournalMedical Physics
Volume36
Issue number6
DOIs
Publication statusPublished - 2009
Externally publishedYes

Fingerprint

Proton Therapy
Rectum
Prostate
Urinary Bladder
Prostatic Neoplasms
Organ Size
Protons
Radiotherapy
Radiation
Water

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

SU‐FF‐T‐476 : Dose‐Sparing Effects of a Rectal Balloon in Proton Therapy of the Prostate. / Lee, D.; Yoon, Myonggeun; Shin, D.; Lim, Y.; Kim, D.; Park, S.; Lee, S.; Lee, J.; Suh, T.

In: Medical Physics, Vol. 36, No. 6, 2009, p. 2632.

Research output: Contribution to journalArticle

Lee, D, Yoon, M, Shin, D, Lim, Y, Kim, D, Park, S, Lee, S, Lee, J & Suh, T 2009, 'SU‐FF‐T‐476: Dose‐Sparing Effects of a Rectal Balloon in Proton Therapy of the Prostate', Medical Physics, vol. 36, no. 6, pp. 2632. https://doi.org/10.1118/1.3181969
Lee, D. ; Yoon, Myonggeun ; Shin, D. ; Lim, Y. ; Kim, D. ; Park, S. ; Lee, S. ; Lee, J. ; Suh, T. / SU‐FF‐T‐476 : Dose‐Sparing Effects of a Rectal Balloon in Proton Therapy of the Prostate. In: Medical Physics. 2009 ; Vol. 36, No. 6. pp. 2632.
@article{204ced1bd0aa4d8cabc5ebb1780add5e,
title = "SU‐FF‐T‐476: Dose‐Sparing Effects of a Rectal Balloon in Proton Therapy of the Prostate",
abstract = "Purpose; The normal organ (bladder, rectum) sparing is very important for radiation therapy of the pelivis. Many people are studying with the effort for rectal and bladder spearing, however the actual circumstances to are satisfied which can not find the method. In this study, the decrease used the balloon to order the rectal dose. The aim of the study was to investigate the dose volume effects of a water‐filled rectal balloon in the rectum. Materials and Methods; We inserted the balloon(100cc water filled, 10cm length, 3cm diameter) in rectum for 10 proton therapy patients with prostate cancers. The systems were loaded with Eclipse proton planning system(Ver. 7.5) and Two sets of CT images before and after ballooning were acquired. Rectum and bladder volumes were delineated on 3‐mm‐thick CT images. A comparison between dose volume histogram(DVH) with and without balloon in rectum for proton therapy of the prostate cancers. Results; More organ and target volume changes with shape because inserted the balloon in rectum. Mean dose of rectal difference between with and without balloon was about 20{\%}, because volume of rectum escape from a radiation area due to the balloon. Mean dose of bladder difference between with and without balloon was about 6{\%}. Conclusion; The rectal ballon is very useful for bladder and rectal sparing with proton therapy of the prostate cancers. This research is believed to be sufficiently accurate and clinically useful.",
author = "D. Lee and Myonggeun Yoon and D. Shin and Y. Lim and D. Kim and S. Park and S. Lee and J. Lee and T. Suh",
year = "2009",
doi = "10.1118/1.3181969",
language = "English",
volume = "36",
pages = "2632",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - SU‐FF‐T‐476

T2 - Dose‐Sparing Effects of a Rectal Balloon in Proton Therapy of the Prostate

AU - Lee, D.

AU - Yoon, Myonggeun

AU - Shin, D.

AU - Lim, Y.

AU - Kim, D.

AU - Park, S.

AU - Lee, S.

AU - Lee, J.

AU - Suh, T.

PY - 2009

Y1 - 2009

N2 - Purpose; The normal organ (bladder, rectum) sparing is very important for radiation therapy of the pelivis. Many people are studying with the effort for rectal and bladder spearing, however the actual circumstances to are satisfied which can not find the method. In this study, the decrease used the balloon to order the rectal dose. The aim of the study was to investigate the dose volume effects of a water‐filled rectal balloon in the rectum. Materials and Methods; We inserted the balloon(100cc water filled, 10cm length, 3cm diameter) in rectum for 10 proton therapy patients with prostate cancers. The systems were loaded with Eclipse proton planning system(Ver. 7.5) and Two sets of CT images before and after ballooning were acquired. Rectum and bladder volumes were delineated on 3‐mm‐thick CT images. A comparison between dose volume histogram(DVH) with and without balloon in rectum for proton therapy of the prostate cancers. Results; More organ and target volume changes with shape because inserted the balloon in rectum. Mean dose of rectal difference between with and without balloon was about 20%, because volume of rectum escape from a radiation area due to the balloon. Mean dose of bladder difference between with and without balloon was about 6%. Conclusion; The rectal ballon is very useful for bladder and rectal sparing with proton therapy of the prostate cancers. This research is believed to be sufficiently accurate and clinically useful.

AB - Purpose; The normal organ (bladder, rectum) sparing is very important for radiation therapy of the pelivis. Many people are studying with the effort for rectal and bladder spearing, however the actual circumstances to are satisfied which can not find the method. In this study, the decrease used the balloon to order the rectal dose. The aim of the study was to investigate the dose volume effects of a water‐filled rectal balloon in the rectum. Materials and Methods; We inserted the balloon(100cc water filled, 10cm length, 3cm diameter) in rectum for 10 proton therapy patients with prostate cancers. The systems were loaded with Eclipse proton planning system(Ver. 7.5) and Two sets of CT images before and after ballooning were acquired. Rectum and bladder volumes were delineated on 3‐mm‐thick CT images. A comparison between dose volume histogram(DVH) with and without balloon in rectum for proton therapy of the prostate cancers. Results; More organ and target volume changes with shape because inserted the balloon in rectum. Mean dose of rectal difference between with and without balloon was about 20%, because volume of rectum escape from a radiation area due to the balloon. Mean dose of bladder difference between with and without balloon was about 6%. Conclusion; The rectal ballon is very useful for bladder and rectal sparing with proton therapy of the prostate cancers. This research is believed to be sufficiently accurate and clinically useful.

UR - http://www.scopus.com/inward/record.url?scp=85024792886&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85024792886&partnerID=8YFLogxK

U2 - 10.1118/1.3181969

DO - 10.1118/1.3181969

M3 - Article

AN - SCOPUS:85024792886

VL - 36

SP - 2632

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -