SU‐GG‐T‐248: Determination of Proton Stopping Power Using MV CT, KV CT & Proton Radiographic Images

J. Kwak, S. Lee, S. Park, J. Shin, S. Park, D. Shin, Myonggeun Yoon, Y. Lim, D. Kim, J. Kim, K. Cho

Research output: Contribution to journalArticle

Abstract

The most of radiotherapy planning systems are operated with the calibration curves of KV CT (Kilo‐Voltage Computational Tomography) images. However, the proton stopping power curve used in proton radiation treatment planning system is optimized for organic materials rather than for metals and other inorganic matter, since the proton stopping power curves obtained with a KV X‐ray beam don't provide one‐to‐one corresponding relation between HU number and Proton stopping power of general materials. At Proton Therapy Center, National Cancer Center(NCC) in Korea, proton treatments started on March 19, 2007. This proton treatment facility is equipped with a cyclotron (Proteus235,IBA). The Proton Therapy Center also has a Tomotherapy machine, 4 LINACs, 2 CT simulator, a conventional simulator. MV CT(Mega‐Voltage Computational Tomography) images provided by the Tomotherpay machine, conventional KV‐CT images taken with conventional CT's and proton radiographic images with Proteus235 have been used to obtain the general proton stopping power relation. We have taken the radiographic images of GAMMAX and CRIS CT calibration phantoms, contrast agents, metals and plastics using various beams. Specially designed Beam Current Modulation of the proton beam provides the beam eye's view of proton. We can use the special beam condition to verify the CT calibration of the Radiation Treatment Planning system and to examine the proton stopping power of various materials for example, a aperture structure, specially, a compensator.

Original languageEnglish
Pages (from-to)2782
Number of pages1
JournalMedical Physics
Volume35
Issue number6
DOIs
Publication statusPublished - 2008
Externally publishedYes

Fingerprint

Protons
Tomography
Proton Therapy
Calibration
Metals
Radiation
Cyclotrons
Therapeutics
Korea
Contrast Media
Plastics
Radiotherapy
X-Rays

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

SU‐GG‐T‐248 : Determination of Proton Stopping Power Using MV CT, KV CT & Proton Radiographic Images. / Kwak, J.; Lee, S.; Park, S.; Shin, J.; Park, S.; Shin, D.; Yoon, Myonggeun; Lim, Y.; Kim, D.; Kim, J.; Cho, K.

In: Medical Physics, Vol. 35, No. 6, 2008, p. 2782.

Research output: Contribution to journalArticle

Kwak, J, Lee, S, Park, S, Shin, J, Park, S, Shin, D, Yoon, M, Lim, Y, Kim, D, Kim, J & Cho, K 2008, 'SU‐GG‐T‐248: Determination of Proton Stopping Power Using MV CT, KV CT & Proton Radiographic Images', Medical Physics, vol. 35, no. 6, pp. 2782. https://doi.org/10.1118/1.2962000
Kwak, J. ; Lee, S. ; Park, S. ; Shin, J. ; Park, S. ; Shin, D. ; Yoon, Myonggeun ; Lim, Y. ; Kim, D. ; Kim, J. ; Cho, K. / SU‐GG‐T‐248 : Determination of Proton Stopping Power Using MV CT, KV CT & Proton Radiographic Images. In: Medical Physics. 2008 ; Vol. 35, No. 6. pp. 2782.
@article{c89429c9f08643d9a0cfb6ff2c30f787,
title = "SU‐GG‐T‐248: Determination of Proton Stopping Power Using MV CT, KV CT & Proton Radiographic Images",
abstract = "The most of radiotherapy planning systems are operated with the calibration curves of KV CT (Kilo‐Voltage Computational Tomography) images. However, the proton stopping power curve used in proton radiation treatment planning system is optimized for organic materials rather than for metals and other inorganic matter, since the proton stopping power curves obtained with a KV X‐ray beam don't provide one‐to‐one corresponding relation between HU number and Proton stopping power of general materials. At Proton Therapy Center, National Cancer Center(NCC) in Korea, proton treatments started on March 19, 2007. This proton treatment facility is equipped with a cyclotron (Proteus235,IBA). The Proton Therapy Center also has a Tomotherapy machine, 4 LINACs, 2 CT simulator, a conventional simulator. MV CT(Mega‐Voltage Computational Tomography) images provided by the Tomotherpay machine, conventional KV‐CT images taken with conventional CT's and proton radiographic images with Proteus235 have been used to obtain the general proton stopping power relation. We have taken the radiographic images of GAMMAX and CRIS CT calibration phantoms, contrast agents, metals and plastics using various beams. Specially designed Beam Current Modulation of the proton beam provides the beam eye's view of proton. We can use the special beam condition to verify the CT calibration of the Radiation Treatment Planning system and to examine the proton stopping power of various materials for example, a aperture structure, specially, a compensator.",
author = "J. Kwak and S. Lee and S. Park and J. Shin and S. Park and D. Shin and Myonggeun Yoon and Y. Lim and D. Kim and J. Kim and K. Cho",
year = "2008",
doi = "10.1118/1.2962000",
language = "English",
volume = "35",
pages = "2782",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - SU‐GG‐T‐248

T2 - Determination of Proton Stopping Power Using MV CT, KV CT & Proton Radiographic Images

AU - Kwak, J.

AU - Lee, S.

AU - Park, S.

AU - Shin, J.

AU - Park, S.

AU - Shin, D.

AU - Yoon, Myonggeun

AU - Lim, Y.

AU - Kim, D.

AU - Kim, J.

AU - Cho, K.

PY - 2008

Y1 - 2008

N2 - The most of radiotherapy planning systems are operated with the calibration curves of KV CT (Kilo‐Voltage Computational Tomography) images. However, the proton stopping power curve used in proton radiation treatment planning system is optimized for organic materials rather than for metals and other inorganic matter, since the proton stopping power curves obtained with a KV X‐ray beam don't provide one‐to‐one corresponding relation between HU number and Proton stopping power of general materials. At Proton Therapy Center, National Cancer Center(NCC) in Korea, proton treatments started on March 19, 2007. This proton treatment facility is equipped with a cyclotron (Proteus235,IBA). The Proton Therapy Center also has a Tomotherapy machine, 4 LINACs, 2 CT simulator, a conventional simulator. MV CT(Mega‐Voltage Computational Tomography) images provided by the Tomotherpay machine, conventional KV‐CT images taken with conventional CT's and proton radiographic images with Proteus235 have been used to obtain the general proton stopping power relation. We have taken the radiographic images of GAMMAX and CRIS CT calibration phantoms, contrast agents, metals and plastics using various beams. Specially designed Beam Current Modulation of the proton beam provides the beam eye's view of proton. We can use the special beam condition to verify the CT calibration of the Radiation Treatment Planning system and to examine the proton stopping power of various materials for example, a aperture structure, specially, a compensator.

AB - The most of radiotherapy planning systems are operated with the calibration curves of KV CT (Kilo‐Voltage Computational Tomography) images. However, the proton stopping power curve used in proton radiation treatment planning system is optimized for organic materials rather than for metals and other inorganic matter, since the proton stopping power curves obtained with a KV X‐ray beam don't provide one‐to‐one corresponding relation between HU number and Proton stopping power of general materials. At Proton Therapy Center, National Cancer Center(NCC) in Korea, proton treatments started on March 19, 2007. This proton treatment facility is equipped with a cyclotron (Proteus235,IBA). The Proton Therapy Center also has a Tomotherapy machine, 4 LINACs, 2 CT simulator, a conventional simulator. MV CT(Mega‐Voltage Computational Tomography) images provided by the Tomotherpay machine, conventional KV‐CT images taken with conventional CT's and proton radiographic images with Proteus235 have been used to obtain the general proton stopping power relation. We have taken the radiographic images of GAMMAX and CRIS CT calibration phantoms, contrast agents, metals and plastics using various beams. Specially designed Beam Current Modulation of the proton beam provides the beam eye's view of proton. We can use the special beam condition to verify the CT calibration of the Radiation Treatment Planning system and to examine the proton stopping power of various materials for example, a aperture structure, specially, a compensator.

UR - http://www.scopus.com/inward/record.url?scp=85024819846&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85024819846&partnerID=8YFLogxK

U2 - 10.1118/1.2962000

DO - 10.1118/1.2962000

M3 - Article

AN - SCOPUS:85024819846

VL - 35

SP - 2782

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -