Tenelectrodes

A new stimulator for inching technique in the diagnosis of carpal tunnel syndrome

Yoon Kyoo Kang, Dong Hwee Kim, Seung Hwa Lee, Miriam Hwang, Myung Soo Han

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

This study was designed evaluate the usefulness of a new multielectrode stimulator, TenElectrodes, in the diagnosis and localization of the compression site in the wrists of carpal tunnel syndrome (CTS) patients. Antidromic inching technique (IT) of the median nerve at the wrist was performed with the TenElectrodes, on 46 controls and 21 CTS patients. In controls, mean conduction delay per centimeter (CD/cm) was 0.21 milliseconds (ms), and maximal CD/cm was 0.27 ms in the segment 3 to 4 centimeters distal to the distal wrist crease. The abnormal cut-off value, calculated as the maximal CD/cm + 2SD, was 0.45 ms. In the CTS group, the maximal CD/cm was 0.56 ms in the segment 2 to 3 centimeters distal to the distal wrist crease, and the CD/cm values in all segments between the distal wrist crease and 4 cm distal to the distal wrist crease were greater than 0.45 ms. Antidromic IT using TenElectrodes may be an easy, fast and accurate method as the electrodes of the stimulator are aligned at 1-cm intervals and are adjustable to the wrist contour by springs.

Original languageEnglish
Pages (from-to)479-484
Number of pages6
JournalYonsei Medical Journal
Volume44
Issue number3
Publication statusPublished - 2003 Jun 30

Fingerprint

Carpal Tunnel Syndrome
Wrist
Median Nerve
Electrodes

Keywords

  • Carpal tunnel syndrome
  • Inching technique
  • Median nerve
  • Multielectrode stimulator
  • Nerve conduction study

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Tenelectrodes : A new stimulator for inching technique in the diagnosis of carpal tunnel syndrome. / Kang, Yoon Kyoo; Kim, Dong Hwee; Lee, Seung Hwa; Hwang, Miriam; Han, Myung Soo.

In: Yonsei Medical Journal, Vol. 44, No. 3, 30.06.2003, p. 479-484.

Research output: Contribution to journalArticle

@article{cacfd97f3a124dfbbb9e068f2aed18a1,
title = "Tenelectrodes: A new stimulator for inching technique in the diagnosis of carpal tunnel syndrome",
abstract = "This study was designed evaluate the usefulness of a new multielectrode stimulator, TenElectrodes, in the diagnosis and localization of the compression site in the wrists of carpal tunnel syndrome (CTS) patients. Antidromic inching technique (IT) of the median nerve at the wrist was performed with the TenElectrodes, on 46 controls and 21 CTS patients. In controls, mean conduction delay per centimeter (CD/cm) was 0.21 milliseconds (ms), and maximal CD/cm was 0.27 ms in the segment 3 to 4 centimeters distal to the distal wrist crease. The abnormal cut-off value, calculated as the maximal CD/cm + 2SD, was 0.45 ms. In the CTS group, the maximal CD/cm was 0.56 ms in the segment 2 to 3 centimeters distal to the distal wrist crease, and the CD/cm values in all segments between the distal wrist crease and 4 cm distal to the distal wrist crease were greater than 0.45 ms. Antidromic IT using TenElectrodes may be an easy, fast and accurate method as the electrodes of the stimulator are aligned at 1-cm intervals and are adjustable to the wrist contour by springs.",
keywords = "Carpal tunnel syndrome, Inching technique, Median nerve, Multielectrode stimulator, Nerve conduction study",
author = "Kang, {Yoon Kyoo} and Kim, {Dong Hwee} and Lee, {Seung Hwa} and Miriam Hwang and Han, {Myung Soo}",
year = "2003",
month = "6",
day = "30",
language = "English",
volume = "44",
pages = "479--484",
journal = "Yonsei Medical Journal",
issn = "0513-5796",
publisher = "Yonsei University College of Medicine",
number = "3",

}

TY - JOUR

T1 - Tenelectrodes

T2 - A new stimulator for inching technique in the diagnosis of carpal tunnel syndrome

AU - Kang, Yoon Kyoo

AU - Kim, Dong Hwee

AU - Lee, Seung Hwa

AU - Hwang, Miriam

AU - Han, Myung Soo

PY - 2003/6/30

Y1 - 2003/6/30

N2 - This study was designed evaluate the usefulness of a new multielectrode stimulator, TenElectrodes, in the diagnosis and localization of the compression site in the wrists of carpal tunnel syndrome (CTS) patients. Antidromic inching technique (IT) of the median nerve at the wrist was performed with the TenElectrodes, on 46 controls and 21 CTS patients. In controls, mean conduction delay per centimeter (CD/cm) was 0.21 milliseconds (ms), and maximal CD/cm was 0.27 ms in the segment 3 to 4 centimeters distal to the distal wrist crease. The abnormal cut-off value, calculated as the maximal CD/cm + 2SD, was 0.45 ms. In the CTS group, the maximal CD/cm was 0.56 ms in the segment 2 to 3 centimeters distal to the distal wrist crease, and the CD/cm values in all segments between the distal wrist crease and 4 cm distal to the distal wrist crease were greater than 0.45 ms. Antidromic IT using TenElectrodes may be an easy, fast and accurate method as the electrodes of the stimulator are aligned at 1-cm intervals and are adjustable to the wrist contour by springs.

AB - This study was designed evaluate the usefulness of a new multielectrode stimulator, TenElectrodes, in the diagnosis and localization of the compression site in the wrists of carpal tunnel syndrome (CTS) patients. Antidromic inching technique (IT) of the median nerve at the wrist was performed with the TenElectrodes, on 46 controls and 21 CTS patients. In controls, mean conduction delay per centimeter (CD/cm) was 0.21 milliseconds (ms), and maximal CD/cm was 0.27 ms in the segment 3 to 4 centimeters distal to the distal wrist crease. The abnormal cut-off value, calculated as the maximal CD/cm + 2SD, was 0.45 ms. In the CTS group, the maximal CD/cm was 0.56 ms in the segment 2 to 3 centimeters distal to the distal wrist crease, and the CD/cm values in all segments between the distal wrist crease and 4 cm distal to the distal wrist crease were greater than 0.45 ms. Antidromic IT using TenElectrodes may be an easy, fast and accurate method as the electrodes of the stimulator are aligned at 1-cm intervals and are adjustable to the wrist contour by springs.

KW - Carpal tunnel syndrome

KW - Inching technique

KW - Median nerve

KW - Multielectrode stimulator

KW - Nerve conduction study

UR - http://www.scopus.com/inward/record.url?scp=0037899077&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0037899077&partnerID=8YFLogxK

M3 - Article

VL - 44

SP - 479

EP - 484

JO - Yonsei Medical Journal

JF - Yonsei Medical Journal

SN - 0513-5796

IS - 3

ER -