Abstract

The primary goal of this study was to analyse the state of patient doses in the field of computed tomography (CT) examinations in the Republic of Korea. All survey data including the CT applications and patient dose details were obtained from general hospitals registered in the Korean Hospital Association. The systematic analysis of the patient dose survey gives target values of the weighted computed tomography dose index (CTDIw) and the dose-length product (DLP). The targeted CTDIw values were 69, 69, 31, 19, 44, 25, 24, 20, 2, 19 and 19 mGy for the brain non-contrast enhancement (BNCE), brain contrast enhancement (BCE), neck, chest, spine, liver, pancreas, stomach, kidneys, abdomen routine and abdomen trauma protocols, respectively. The targeted DLP values were 1056, 2112, 762, 1234, 1338, 2794, 2742, 2378, 2836, 1844 and 1939 mGy cm for the BNCE, BCE, neck, chest, spine, liver, pancreas, stomach, kidneys, abdomen routine and abdomen trauma protocols, respectively. Comparing with the EUR recommendation, especially in the DLP, the adjustment of the total scan phase frequency and the shortening of the scan phase in each scan phase are needed to reduce the patients radiation exposure to international standards.

Original languageEnglish
Article numberncp236
Pages (from-to)137-143
Number of pages7
JournalRadiation Protection Dosimetry
Volume138
Issue number2
DOIs
Publication statusPublished - 2009 Oct 28

Fingerprint

Korea
Abdomen
tomography
examination
Tomography
abdomen
dosage
Brain
brain
Pancreas
Stomach
Spine
Neck
Thorax
pancreas
stomach
spine
augmentation
Kidney
chest

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Radiation
  • Radiology Nuclear Medicine and imaging
  • Public Health, Environmental and Occupational Health

Cite this

The development of a guidance level for patient dose for CT examinations in Korea. / Choi, Jong Hak; Cha, Sang Hoon; Lee, Ki Yeol; Shin, Dong Chul; Kang, Jung Ho; Kim, You Hyun; Kim, Kihyun; Cho, Pyong Kon.

In: Radiation Protection Dosimetry, Vol. 138, No. 2, ncp236, 28.10.2009, p. 137-143.

Research output: Contribution to journalArticle

Choi, Jong Hak ; Cha, Sang Hoon ; Lee, Ki Yeol ; Shin, Dong Chul ; Kang, Jung Ho ; Kim, You Hyun ; Kim, Kihyun ; Cho, Pyong Kon. / The development of a guidance level for patient dose for CT examinations in Korea. In: Radiation Protection Dosimetry. 2009 ; Vol. 138, No. 2. pp. 137-143.
@article{7bdfa9b8d3474b7e96bc4f46f1eea993,
title = "The development of a guidance level for patient dose for CT examinations in Korea",
abstract = "The primary goal of this study was to analyse the state of patient doses in the field of computed tomography (CT) examinations in the Republic of Korea. All survey data including the CT applications and patient dose details were obtained from general hospitals registered in the Korean Hospital Association. The systematic analysis of the patient dose survey gives target values of the weighted computed tomography dose index (CTDIw) and the dose-length product (DLP). The targeted CTDIw values were 69, 69, 31, 19, 44, 25, 24, 20, 2, 19 and 19 mGy for the brain non-contrast enhancement (BNCE), brain contrast enhancement (BCE), neck, chest, spine, liver, pancreas, stomach, kidneys, abdomen routine and abdomen trauma protocols, respectively. The targeted DLP values were 1056, 2112, 762, 1234, 1338, 2794, 2742, 2378, 2836, 1844 and 1939 mGy cm for the BNCE, BCE, neck, chest, spine, liver, pancreas, stomach, kidneys, abdomen routine and abdomen trauma protocols, respectively. Comparing with the EUR recommendation, especially in the DLP, the adjustment of the total scan phase frequency and the shortening of the scan phase in each scan phase are needed to reduce the patients radiation exposure to international standards.",
author = "Choi, {Jong Hak} and Cha, {Sang Hoon} and Lee, {Ki Yeol} and Shin, {Dong Chul} and Kang, {Jung Ho} and Kim, {You Hyun} and Kihyun Kim and Cho, {Pyong Kon}",
year = "2009",
month = "10",
day = "28",
doi = "10.1093/rpd/ncp236",
language = "English",
volume = "138",
pages = "137--143",
journal = "Radiation Protection Dosimetry",
issn = "0144-8420",
publisher = "Oxford University Press",
number = "2",

}

TY - JOUR

T1 - The development of a guidance level for patient dose for CT examinations in Korea

AU - Choi, Jong Hak

AU - Cha, Sang Hoon

AU - Lee, Ki Yeol

AU - Shin, Dong Chul

AU - Kang, Jung Ho

AU - Kim, You Hyun

AU - Kim, Kihyun

AU - Cho, Pyong Kon

PY - 2009/10/28

Y1 - 2009/10/28

N2 - The primary goal of this study was to analyse the state of patient doses in the field of computed tomography (CT) examinations in the Republic of Korea. All survey data including the CT applications and patient dose details were obtained from general hospitals registered in the Korean Hospital Association. The systematic analysis of the patient dose survey gives target values of the weighted computed tomography dose index (CTDIw) and the dose-length product (DLP). The targeted CTDIw values were 69, 69, 31, 19, 44, 25, 24, 20, 2, 19 and 19 mGy for the brain non-contrast enhancement (BNCE), brain contrast enhancement (BCE), neck, chest, spine, liver, pancreas, stomach, kidneys, abdomen routine and abdomen trauma protocols, respectively. The targeted DLP values were 1056, 2112, 762, 1234, 1338, 2794, 2742, 2378, 2836, 1844 and 1939 mGy cm for the BNCE, BCE, neck, chest, spine, liver, pancreas, stomach, kidneys, abdomen routine and abdomen trauma protocols, respectively. Comparing with the EUR recommendation, especially in the DLP, the adjustment of the total scan phase frequency and the shortening of the scan phase in each scan phase are needed to reduce the patients radiation exposure to international standards.

AB - The primary goal of this study was to analyse the state of patient doses in the field of computed tomography (CT) examinations in the Republic of Korea. All survey data including the CT applications and patient dose details were obtained from general hospitals registered in the Korean Hospital Association. The systematic analysis of the patient dose survey gives target values of the weighted computed tomography dose index (CTDIw) and the dose-length product (DLP). The targeted CTDIw values were 69, 69, 31, 19, 44, 25, 24, 20, 2, 19 and 19 mGy for the brain non-contrast enhancement (BNCE), brain contrast enhancement (BCE), neck, chest, spine, liver, pancreas, stomach, kidneys, abdomen routine and abdomen trauma protocols, respectively. The targeted DLP values were 1056, 2112, 762, 1234, 1338, 2794, 2742, 2378, 2836, 1844 and 1939 mGy cm for the BNCE, BCE, neck, chest, spine, liver, pancreas, stomach, kidneys, abdomen routine and abdomen trauma protocols, respectively. Comparing with the EUR recommendation, especially in the DLP, the adjustment of the total scan phase frequency and the shortening of the scan phase in each scan phase are needed to reduce the patients radiation exposure to international standards.

UR - http://www.scopus.com/inward/record.url?scp=77950269259&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77950269259&partnerID=8YFLogxK

U2 - 10.1093/rpd/ncp236

DO - 10.1093/rpd/ncp236

M3 - Article

VL - 138

SP - 137

EP - 143

JO - Radiation Protection Dosimetry

JF - Radiation Protection Dosimetry

SN - 0144-8420

IS - 2

M1 - ncp236

ER -