The effect of acid rain on the tracking deterioration of elastomer

Yi Dong-Young, June Ho Lee, Seong Hwangbo, Min Koo Han, Kwang Suck Suh, Sang Joon Kim, Dong Won Jeong

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

The IEC 587 tracking test was performed on an elastomer which was soaked in artificial acid rain under a constant temperature and humidity in a climate chamber. The scintillation discharge was counted and the average current on the sample surface was measured at the same time. It was observed that the artificial acid rain accelerated the degradation of the elastomer and consequently reduced the tracking resistance of the material as evidenced by the fact that the average ignition time decreased as the aging period increased. The increase of scintillation discharge may be responsible for the decrease of ignition time proportionately as the aging period increases. The generation of scintillation discharge is closely related to the variation of the average current on the sample surface.

Original languageEnglish
Title of host publicationConference Record of the 1992 IEEE International Symposium on Electrical Insulation, ISEI 1992
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages258-261
Number of pages4
ISBN (Electronic)078030649X
DOIs
Publication statusPublished - 1992 Jan 1
Event1992 IEEE International Symposium on Electrical Insulation, ISEI 1992 - Baltimore, United States
Duration: 1992 Jun 71992 Jun 10

Publication series

NameConference Record of IEEE International Symposium on Electrical Insulation
Volume1992-June
ISSN (Print)0164-2006

Conference

Conference1992 IEEE International Symposium on Electrical Insulation, ISEI 1992
CountryUnited States
CityBaltimore
Period92/6/792/6/10

Fingerprint

Acid rain
Scintillation
Elastomers
Deterioration
Ignition
Aging of materials
Atmospheric humidity
Degradation
Temperature

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

Dong-Young, Y., Lee, J. H., Hwangbo, S., Han, M. K., Suh, K. S., Kim, S. J., & Jeong, D. W. (1992). The effect of acid rain on the tracking deterioration of elastomer. In Conference Record of the 1992 IEEE International Symposium on Electrical Insulation, ISEI 1992 (pp. 258-261). [247007] (Conference Record of IEEE International Symposium on Electrical Insulation; Vol. 1992-June). Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/ELINSL.1992.247007

The effect of acid rain on the tracking deterioration of elastomer. / Dong-Young, Yi; Lee, June Ho; Hwangbo, Seong; Han, Min Koo; Suh, Kwang Suck; Kim, Sang Joon; Jeong, Dong Won.

Conference Record of the 1992 IEEE International Symposium on Electrical Insulation, ISEI 1992. Institute of Electrical and Electronics Engineers Inc., 1992. p. 258-261 247007 (Conference Record of IEEE International Symposium on Electrical Insulation; Vol. 1992-June).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Dong-Young, Y, Lee, JH, Hwangbo, S, Han, MK, Suh, KS, Kim, SJ & Jeong, DW 1992, The effect of acid rain on the tracking deterioration of elastomer. in Conference Record of the 1992 IEEE International Symposium on Electrical Insulation, ISEI 1992., 247007, Conference Record of IEEE International Symposium on Electrical Insulation, vol. 1992-June, Institute of Electrical and Electronics Engineers Inc., pp. 258-261, 1992 IEEE International Symposium on Electrical Insulation, ISEI 1992, Baltimore, United States, 92/6/7. https://doi.org/10.1109/ELINSL.1992.247007
Dong-Young Y, Lee JH, Hwangbo S, Han MK, Suh KS, Kim SJ et al. The effect of acid rain on the tracking deterioration of elastomer. In Conference Record of the 1992 IEEE International Symposium on Electrical Insulation, ISEI 1992. Institute of Electrical and Electronics Engineers Inc. 1992. p. 258-261. 247007. (Conference Record of IEEE International Symposium on Electrical Insulation). https://doi.org/10.1109/ELINSL.1992.247007
Dong-Young, Yi ; Lee, June Ho ; Hwangbo, Seong ; Han, Min Koo ; Suh, Kwang Suck ; Kim, Sang Joon ; Jeong, Dong Won. / The effect of acid rain on the tracking deterioration of elastomer. Conference Record of the 1992 IEEE International Symposium on Electrical Insulation, ISEI 1992. Institute of Electrical and Electronics Engineers Inc., 1992. pp. 258-261 (Conference Record of IEEE International Symposium on Electrical Insulation).
@inproceedings{41d30fefbefc4306b125992938755ef3,
title = "The effect of acid rain on the tracking deterioration of elastomer",
abstract = "The IEC 587 tracking test was performed on an elastomer which was soaked in artificial acid rain under a constant temperature and humidity in a climate chamber. The scintillation discharge was counted and the average current on the sample surface was measured at the same time. It was observed that the artificial acid rain accelerated the degradation of the elastomer and consequently reduced the tracking resistance of the material as evidenced by the fact that the average ignition time decreased as the aging period increased. The increase of scintillation discharge may be responsible for the decrease of ignition time proportionately as the aging period increases. The generation of scintillation discharge is closely related to the variation of the average current on the sample surface.",
author = "Yi Dong-Young and Lee, {June Ho} and Seong Hwangbo and Han, {Min Koo} and Suh, {Kwang Suck} and Kim, {Sang Joon} and Jeong, {Dong Won}",
year = "1992",
month = "1",
day = "1",
doi = "10.1109/ELINSL.1992.247007",
language = "English",
series = "Conference Record of IEEE International Symposium on Electrical Insulation",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
pages = "258--261",
booktitle = "Conference Record of the 1992 IEEE International Symposium on Electrical Insulation, ISEI 1992",

}

TY - GEN

T1 - The effect of acid rain on the tracking deterioration of elastomer

AU - Dong-Young, Yi

AU - Lee, June Ho

AU - Hwangbo, Seong

AU - Han, Min Koo

AU - Suh, Kwang Suck

AU - Kim, Sang Joon

AU - Jeong, Dong Won

PY - 1992/1/1

Y1 - 1992/1/1

N2 - The IEC 587 tracking test was performed on an elastomer which was soaked in artificial acid rain under a constant temperature and humidity in a climate chamber. The scintillation discharge was counted and the average current on the sample surface was measured at the same time. It was observed that the artificial acid rain accelerated the degradation of the elastomer and consequently reduced the tracking resistance of the material as evidenced by the fact that the average ignition time decreased as the aging period increased. The increase of scintillation discharge may be responsible for the decrease of ignition time proportionately as the aging period increases. The generation of scintillation discharge is closely related to the variation of the average current on the sample surface.

AB - The IEC 587 tracking test was performed on an elastomer which was soaked in artificial acid rain under a constant temperature and humidity in a climate chamber. The scintillation discharge was counted and the average current on the sample surface was measured at the same time. It was observed that the artificial acid rain accelerated the degradation of the elastomer and consequently reduced the tracking resistance of the material as evidenced by the fact that the average ignition time decreased as the aging period increased. The increase of scintillation discharge may be responsible for the decrease of ignition time proportionately as the aging period increases. The generation of scintillation discharge is closely related to the variation of the average current on the sample surface.

UR - http://www.scopus.com/inward/record.url?scp=85066327027&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85066327027&partnerID=8YFLogxK

U2 - 10.1109/ELINSL.1992.247007

DO - 10.1109/ELINSL.1992.247007

M3 - Conference contribution

AN - SCOPUS:85066327027

T3 - Conference Record of IEEE International Symposium on Electrical Insulation

SP - 258

EP - 261

BT - Conference Record of the 1992 IEEE International Symposium on Electrical Insulation, ISEI 1992

PB - Institute of Electrical and Electronics Engineers Inc.

ER -