The effect of load carrying and floor contaminants on slip and fall parameters

Rohae Myung, James L. Smith

Research output: Contribution to journalArticle

49 Citations (Scopus)

Abstract

A study was conducted to provide set-up values of an important biomechanical parameter, heel velocity, for slip resistance testers. Four different floor surfaces (with or without oil contaminant) were prepared for ten subjects with each walking at a fixed velocity while carrying five different loads. Stride lengths were also measured to find whether a significant difference existed between a carrying method typically used in industry (two-handed carrying of a load in a tote box held directly in front of the body) and previously used load carrying techniques (backpack and front-back pack systems). A programmable slip resistance tester was used to measure dynamic coefficient of friction with conventional set-up values for heel velocity. The results showed that the conventional set-up value for heel velocity is valid for dry floors but is too low on oily floors because faster transfer of body weight was seen owing to decreased stride length. On oily floors, heel velocities of 60 to 140 cm/s would be recommended. An abnormal gait pattern, short stride length, was seen on oily floors or with heavy load carriage because subjects adjusted their stride length for a better stance.

Original languageEnglish
Pages (from-to)235-246
Number of pages12
JournalErgonomics
Volume40
Issue number2
DOIs
Publication statusPublished - 1997 Feb 1

Fingerprint

Accidental Falls
Heel
Impurities
Values
body weight
Friction
Gait
industry
Walking
Industry
Oils
Body Weight

Keywords

  • Dynamic coefficient of friction
  • Floor slipperiness
  • Heel velocity
  • Slip and fall accidents
  • Stride length
  • Vertical force

ASJC Scopus subject areas

  • Industrial and Manufacturing Engineering
  • Human Factors and Ergonomics
  • Psychology(all)
  • Applied Psychology

Cite this

The effect of load carrying and floor contaminants on slip and fall parameters. / Myung, Rohae; Smith, James L.

In: Ergonomics, Vol. 40, No. 2, 01.02.1997, p. 235-246.

Research output: Contribution to journalArticle

@article{bfb1ab4c5be2488cb292ca4970785320,
title = "The effect of load carrying and floor contaminants on slip and fall parameters",
abstract = "A study was conducted to provide set-up values of an important biomechanical parameter, heel velocity, for slip resistance testers. Four different floor surfaces (with or without oil contaminant) were prepared for ten subjects with each walking at a fixed velocity while carrying five different loads. Stride lengths were also measured to find whether a significant difference existed between a carrying method typically used in industry (two-handed carrying of a load in a tote box held directly in front of the body) and previously used load carrying techniques (backpack and front-back pack systems). A programmable slip resistance tester was used to measure dynamic coefficient of friction with conventional set-up values for heel velocity. The results showed that the conventional set-up value for heel velocity is valid for dry floors but is too low on oily floors because faster transfer of body weight was seen owing to decreased stride length. On oily floors, heel velocities of 60 to 140 cm/s would be recommended. An abnormal gait pattern, short stride length, was seen on oily floors or with heavy load carriage because subjects adjusted their stride length for a better stance.",
keywords = "Dynamic coefficient of friction, Floor slipperiness, Heel velocity, Slip and fall accidents, Stride length, Vertical force",
author = "Rohae Myung and Smith, {James L.}",
year = "1997",
month = "2",
day = "1",
doi = "10.1080/001401397188323",
language = "English",
volume = "40",
pages = "235--246",
journal = "Ergonomics",
issn = "0014-0139",
publisher = "Taylor and Francis Ltd.",
number = "2",

}

TY - JOUR

T1 - The effect of load carrying and floor contaminants on slip and fall parameters

AU - Myung, Rohae

AU - Smith, James L.

PY - 1997/2/1

Y1 - 1997/2/1

N2 - A study was conducted to provide set-up values of an important biomechanical parameter, heel velocity, for slip resistance testers. Four different floor surfaces (with or without oil contaminant) were prepared for ten subjects with each walking at a fixed velocity while carrying five different loads. Stride lengths were also measured to find whether a significant difference existed between a carrying method typically used in industry (two-handed carrying of a load in a tote box held directly in front of the body) and previously used load carrying techniques (backpack and front-back pack systems). A programmable slip resistance tester was used to measure dynamic coefficient of friction with conventional set-up values for heel velocity. The results showed that the conventional set-up value for heel velocity is valid for dry floors but is too low on oily floors because faster transfer of body weight was seen owing to decreased stride length. On oily floors, heel velocities of 60 to 140 cm/s would be recommended. An abnormal gait pattern, short stride length, was seen on oily floors or with heavy load carriage because subjects adjusted their stride length for a better stance.

AB - A study was conducted to provide set-up values of an important biomechanical parameter, heel velocity, for slip resistance testers. Four different floor surfaces (with or without oil contaminant) were prepared for ten subjects with each walking at a fixed velocity while carrying five different loads. Stride lengths were also measured to find whether a significant difference existed between a carrying method typically used in industry (two-handed carrying of a load in a tote box held directly in front of the body) and previously used load carrying techniques (backpack and front-back pack systems). A programmable slip resistance tester was used to measure dynamic coefficient of friction with conventional set-up values for heel velocity. The results showed that the conventional set-up value for heel velocity is valid for dry floors but is too low on oily floors because faster transfer of body weight was seen owing to decreased stride length. On oily floors, heel velocities of 60 to 140 cm/s would be recommended. An abnormal gait pattern, short stride length, was seen on oily floors or with heavy load carriage because subjects adjusted their stride length for a better stance.

KW - Dynamic coefficient of friction

KW - Floor slipperiness

KW - Heel velocity

KW - Slip and fall accidents

KW - Stride length

KW - Vertical force

UR - http://www.scopus.com/inward/record.url?scp=0031080873&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031080873&partnerID=8YFLogxK

U2 - 10.1080/001401397188323

DO - 10.1080/001401397188323

M3 - Article

C2 - 9118934

AN - SCOPUS:0031080873

VL - 40

SP - 235

EP - 246

JO - Ergonomics

JF - Ergonomics

SN - 0014-0139

IS - 2

ER -